Fx Copy
LaTeX Copy
Zero Sequence Voltage consists of a balanced three-phase voltage and current, phasors of which all have the same phase angles and rotate counterclockwise together. Check FAQs
V0=V1+(3ZfI0)
V0 - Zero Sequence Voltage?V1 - Positive Sequence Voltage?Zf - Fault Impedance?I0 - Zero Sequence Current?

Zero Sequence Voltage using Fault Impedance (LLGF) Example

With values
With units
Only example

Here is how the Zero Sequence Voltage using Fault Impedance (LLGF) equation looks like with Values.

Here is how the Zero Sequence Voltage using Fault Impedance (LLGF) equation looks like with Units.

Here is how the Zero Sequence Voltage using Fault Impedance (LLGF) equation looks like.

27.4Edit=17.5Edit+(31.5Edit2.2Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Zero Sequence Voltage using Fault Impedance (LLGF)

Zero Sequence Voltage using Fault Impedance (LLGF) Solution

Follow our step by step solution on how to calculate Zero Sequence Voltage using Fault Impedance (LLGF)?

FIRST Step Consider the formula
V0=V1+(3ZfI0)
Next Step Substitute values of Variables
V0=17.5V+(31.5Ω2.2A)
Next Step Prepare to Evaluate
V0=17.5+(31.52.2)
LAST Step Evaluate
V0=27.4V

Zero Sequence Voltage using Fault Impedance (LLGF) Formula Elements

Variables
Zero Sequence Voltage
Zero Sequence Voltage consists of a balanced three-phase voltage and current, phasors of which all have the same phase angles and rotate counterclockwise together.
Symbol: V0
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Positive Sequence Voltage
Positive Sequence Voltage consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Symbol: V1
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Fault Impedance
Fault Impedance is a measure of the resistance and reactance in an electrical circuit that is used to calculate the fault current that flows through the circuit in the event of a fault.
Symbol: Zf
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Zero Sequence Current
Zero Sequence Current consists of a balanced three-phase current, phasors of which all have the same phase angles and rotate counterclockwise together.
Symbol: I0
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.

Other Formulas to find Zero Sequence Voltage

​Go Zero Sequence Voltage using A-Phase Voltage (LLGF)
V0=Va+(2Vb)3
​Go Zero Sequence Voltage using B-Phase Voltage (LLGF)
V0=Vb+V1

Other formulas in Voltage and EMF category

​Go B-Phase Voltage using Fault Current (LLGF)
Vb=ZfIf
​Go C-Phase Voltage using Fault Current (LLGF)
Vc=IfZf
​Go B-Phase Voltage using Zero Sequence Current (LLGF)
Vb=3I0Zf
​Go C-Phase Voltage using Zero Sequence Current (LLGF)
Vc=3I0Zf

How to Evaluate Zero Sequence Voltage using Fault Impedance (LLGF)?

Zero Sequence Voltage using Fault Impedance (LLGF) evaluator uses Zero Sequence Voltage = Positive Sequence Voltage+(3*Fault Impedance*Zero Sequence Current) to evaluate the Zero Sequence Voltage, The Zero Sequence voltage using fault impedance (LLGF) formula is consists of a balanced three-phase current, phasors of which all have the same phase angles and rotate counterclockwise together. Zero Sequence Voltage is denoted by V0 symbol.

How to evaluate Zero Sequence Voltage using Fault Impedance (LLGF) using this online evaluator? To use this online evaluator for Zero Sequence Voltage using Fault Impedance (LLGF), enter Positive Sequence Voltage (V1), Fault Impedance (Zf) & Zero Sequence Current (I0) and hit the calculate button.

FAQs on Zero Sequence Voltage using Fault Impedance (LLGF)

What is the formula to find Zero Sequence Voltage using Fault Impedance (LLGF)?
The formula of Zero Sequence Voltage using Fault Impedance (LLGF) is expressed as Zero Sequence Voltage = Positive Sequence Voltage+(3*Fault Impedance*Zero Sequence Current). Here is an example- 23.4 = 17.5+(3*1.5*2.2).
How to calculate Zero Sequence Voltage using Fault Impedance (LLGF)?
With Positive Sequence Voltage (V1), Fault Impedance (Zf) & Zero Sequence Current (I0) we can find Zero Sequence Voltage using Fault Impedance (LLGF) using the formula - Zero Sequence Voltage = Positive Sequence Voltage+(3*Fault Impedance*Zero Sequence Current).
What are the other ways to Calculate Zero Sequence Voltage?
Here are the different ways to Calculate Zero Sequence Voltage-
  • Zero Sequence Voltage=(A Phase Voltage+(2*B Phase Voltage))/3OpenImg
  • Zero Sequence Voltage=B Phase Voltage+Positive Sequence VoltageOpenImg
Can the Zero Sequence Voltage using Fault Impedance (LLGF) be negative?
Yes, the Zero Sequence Voltage using Fault Impedance (LLGF), measured in Electric Potential can be negative.
Which unit is used to measure Zero Sequence Voltage using Fault Impedance (LLGF)?
Zero Sequence Voltage using Fault Impedance (LLGF) is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Zero Sequence Voltage using Fault Impedance (LLGF) can be measured.
Copied!