Zero Sequence Current for Star Connected Load Formula

Fx Copy
LaTeX Copy
Zero Sequence Current is consists of a balanced three-phase current, phasors of which all have the same phase angles and rotate counterclockwise together. Check FAQs
I0=V0Zy+(3Zf)
I0 - Zero Sequence Current?V0 - Zero Sequence Voltage?Zy - Star Impedance?Zf - Fault Impedance?

Zero Sequence Current for Star Connected Load Example

With values
With units
Only example

Here is how the Zero Sequence Current for Star Connected Load equation looks like with Values.

Here is how the Zero Sequence Current for Star Connected Load equation looks like with Units.

Here is how the Zero Sequence Current for Star Connected Load equation looks like.

2.1874Edit=60.59Edit4.12Edit+(37.86Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Zero Sequence Current for Star Connected Load

Zero Sequence Current for Star Connected Load Solution

Follow our step by step solution on how to calculate Zero Sequence Current for Star Connected Load?

FIRST Step Consider the formula
I0=V0Zy+(3Zf)
Next Step Substitute values of Variables
I0=60.59V4.12Ω+(37.86Ω)
Next Step Prepare to Evaluate
I0=60.594.12+(37.86)
Next Step Evaluate
I0=2.18736462093863A
LAST Step Rounding Answer
I0=2.1874A

Zero Sequence Current for Star Connected Load Formula Elements

Variables
Zero Sequence Current
Zero Sequence Current is consists of a balanced three-phase current, phasors of which all have the same phase angles and rotate counterclockwise together.
Symbol: I0
Measurement: Electric CurrentUnit: A
Note: Value should be greater than 0.
Zero Sequence Voltage
Zero Sequence Voltage is consists of a balanced three-phase voltage and current, phasors of which all have the same phase angles and rotate counterclockwise together.
Symbol: V0
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Star Impedance
Star Impedance is defined as the impedance Of star connected network.
Symbol: Zy
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Fault Impedance
Fault Impedance is defined as the impedance that caused the fault.
Symbol: Zf
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.

Other formulas in Sequence Current and Voltage category

​Go Negative Sequence Voltage for Star Connected Load
V2=I2Zy
​Go Zero Sequence Voltage for Star Connected Load
V0=(Zy+3Zf)I0
​Go Positive Sequence Voltage for Delta Connected Load
V1=ZdI13
​Go Positive Sequence Voltage for Star Connected Load
V1=ZyI1

How to Evaluate Zero Sequence Current for Star Connected Load?

Zero Sequence Current for Star Connected Load evaluator uses Zero Sequence Current = Zero Sequence Voltage/(Star Impedance+(3*Fault Impedance)) to evaluate the Zero Sequence Current, The Zero Sequence Current for Star Connected Load formula consists of a balanced three-phase current, phasors of which all have the same phase angles and rotate counterclockwise together. Zero Sequence Current is denoted by I0 symbol.

How to evaluate Zero Sequence Current for Star Connected Load using this online evaluator? To use this online evaluator for Zero Sequence Current for Star Connected Load, enter Zero Sequence Voltage (V0), Star Impedance (Zy) & Fault Impedance (Zf) and hit the calculate button.

FAQs on Zero Sequence Current for Star Connected Load

What is the formula to find Zero Sequence Current for Star Connected Load?
The formula of Zero Sequence Current for Star Connected Load is expressed as Zero Sequence Current = Zero Sequence Voltage/(Star Impedance+(3*Fault Impedance)). Here is an example- 2.189736 = 60.59/(4.12+(3*7.86)).
How to calculate Zero Sequence Current for Star Connected Load?
With Zero Sequence Voltage (V0), Star Impedance (Zy) & Fault Impedance (Zf) we can find Zero Sequence Current for Star Connected Load using the formula - Zero Sequence Current = Zero Sequence Voltage/(Star Impedance+(3*Fault Impedance)).
Can the Zero Sequence Current for Star Connected Load be negative?
No, the Zero Sequence Current for Star Connected Load, measured in Electric Current cannot be negative.
Which unit is used to measure Zero Sequence Current for Star Connected Load?
Zero Sequence Current for Star Connected Load is usually measured using the Ampere[A] for Electric Current. Milliampere[A], Microampere[A], Centiampere[A] are the few other units in which Zero Sequence Current for Star Connected Load can be measured.
Copied!