XOR Phase Detector Voltage Formula

Fx Copy
LaTeX Copy
XOR Phase Detector Voltage is the output voltage of the phase comparator. Check FAQs
Vpd=ΦerrKpd
Vpd - XOR Phase Detector Voltage?Φerr - XOR Phase Detector Phase?Kpd - XOR Phase Detector Average Voltage?

XOR Phase Detector Voltage Example

With values
With units
Only example

Here is how the XOR Phase Detector Voltage equation looks like with Values.

Here is how the XOR Phase Detector Voltage equation looks like with Units.

Here is how the XOR Phase Detector Voltage equation looks like.

0.4999Edit=9.3Edit3.08Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category CMOS Design and Applications » fx XOR Phase Detector Voltage

XOR Phase Detector Voltage Solution

Follow our step by step solution on how to calculate XOR Phase Detector Voltage?

FIRST Step Consider the formula
Vpd=ΦerrKpd
Next Step Substitute values of Variables
Vpd=9.3°3.08V
Next Step Convert Units
Vpd=0.1623rad3.08V
Next Step Prepare to Evaluate
Vpd=0.16233.08
Next Step Evaluate
Vpd=0.499932110941161V
LAST Step Rounding Answer
Vpd=0.4999V

XOR Phase Detector Voltage Formula Elements

Variables
XOR Phase Detector Voltage
XOR Phase Detector Voltage is the output voltage of the phase comparator.
Symbol: Vpd
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
XOR Phase Detector Phase
XOR Phase Detector Phase where phase detector is a frequency mixer, an analog multiplier that generates a voltage signal which represents the difference in phase between two signal inputs.
Symbol: Φerr
Measurement: AngleUnit: °
Note: Value should be greater than 0.
XOR Phase Detector Average Voltage
XOR Phase Detector Average Voltage is the averaging of all the instantaneous values along the time axis with time being one full period, (T).
Symbol: Kpd
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.

Other formulas in CMOS Time Characteristics category

​Go Aperture Time for Rising Input
tar=Tsetup1+Thold0
​Go Aperture Time for Falling Input
taf=Tsetup0+Thold1
​Go Setup Time at High Logic
Tsetup1=tar-Thold0
​Go Setup Time at Low Logic
Tsetup0=taf-Thold1

How to Evaluate XOR Phase Detector Voltage?

XOR Phase Detector Voltage evaluator uses XOR Phase Detector Voltage = XOR Phase Detector Phase*XOR Phase Detector Average Voltage to evaluate the XOR Phase Detector Voltage, The XOR Phase Detector Voltage formula is defined as the pressure from an electrical circuit's power source that pushes charged electrons (current) through a conducting loop, enabling them to do work such as illuminating a light. XOR Phase Detector Voltage is denoted by Vpd symbol.

How to evaluate XOR Phase Detector Voltage using this online evaluator? To use this online evaluator for XOR Phase Detector Voltage, enter XOR Phase Detector Phase err) & XOR Phase Detector Average Voltage (Kpd) and hit the calculate button.

FAQs on XOR Phase Detector Voltage

What is the formula to find XOR Phase Detector Voltage?
The formula of XOR Phase Detector Voltage is expressed as XOR Phase Detector Voltage = XOR Phase Detector Phase*XOR Phase Detector Average Voltage. Here is an example- 0.507996 = 0.162315620435442*3.08.
How to calculate XOR Phase Detector Voltage?
With XOR Phase Detector Phase err) & XOR Phase Detector Average Voltage (Kpd) we can find XOR Phase Detector Voltage using the formula - XOR Phase Detector Voltage = XOR Phase Detector Phase*XOR Phase Detector Average Voltage.
Can the XOR Phase Detector Voltage be negative?
No, the XOR Phase Detector Voltage, measured in Electric Potential cannot be negative.
Which unit is used to measure XOR Phase Detector Voltage?
XOR Phase Detector Voltage is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which XOR Phase Detector Voltage can be measured.