XOR Phase Detector Phase where phase detector is a frequency mixer, an analog multiplier that generates a voltage signal which represents the difference in phase between two signal inputs. Check FAQs
Φerr=VpdKpd
Φerr - XOR Phase Detector Phase?Vpd - XOR Phase Detector Voltage?Kpd - XOR Phase Detector Average Voltage?

XOR Phase Detector Phase Example

With values
With units
Only example

Here is how the XOR Phase Detector Phase equation looks like with Values.

Here is how the XOR Phase Detector Phase equation looks like with Units.

Here is how the XOR Phase Detector Phase equation looks like.

9.3013Edit=0.5Edit3.08Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category CMOS Design and Applications » fx XOR Phase Detector Phase

XOR Phase Detector Phase Solution

Follow our step by step solution on how to calculate XOR Phase Detector Phase?

FIRST Step Consider the formula
Φerr=VpdKpd
Next Step Substitute values of Variables
Φerr=0.5V3.08V
Next Step Prepare to Evaluate
Φerr=0.53.08
Next Step Evaluate
Φerr=0.162337662337662rad
Next Step Convert to Output's Unit
Φerr=9.30126290796966°
LAST Step Rounding Answer
Φerr=9.3013°

XOR Phase Detector Phase Formula Elements

Variables
XOR Phase Detector Phase
XOR Phase Detector Phase where phase detector is a frequency mixer, an analog multiplier that generates a voltage signal which represents the difference in phase between two signal inputs.
Symbol: Φerr
Measurement: AngleUnit: °
Note: Value should be greater than 0.
XOR Phase Detector Voltage
XOR Phase Detector Voltage is the output voltage of the phase comparator.
Symbol: Vpd
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
XOR Phase Detector Average Voltage
XOR Phase Detector Average Voltage is the averaging of all the instantaneous values along the time axis with time being one full period, (T).
Symbol: Kpd
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.

Other Formulas to find XOR Phase Detector Phase

​Go XOR Phase Detector Phase with reference to Detector Current
Φerr=ipdKpd

Other formulas in CMOS Time Characteristics category

​Go Aperture Time for Rising Input
tar=Tsetup1+Thold0
​Go Aperture Time for Falling Input
taf=Tsetup0+Thold1
​Go Setup Time at High Logic
Tsetup1=tar-Thold0
​Go Setup Time at Low Logic
Tsetup0=taf-Thold1

How to Evaluate XOR Phase Detector Phase?

XOR Phase Detector Phase evaluator uses XOR Phase Detector Phase = XOR Phase Detector Voltage/XOR Phase Detector Average Voltage to evaluate the XOR Phase Detector Phase, The XOR Phase Detector Phase formula is defined as a phase detector or phase comparator is a frequency mixer, analog multiplier or logic circuit that generates a voltage signal which represents the difference in phase between two signal inputs. It is an essential element of the phase-locked loop (PLL). XOR Phase Detector Phase is denoted by Φerr symbol.

How to evaluate XOR Phase Detector Phase using this online evaluator? To use this online evaluator for XOR Phase Detector Phase, enter XOR Phase Detector Voltage (Vpd) & XOR Phase Detector Average Voltage (Kpd) and hit the calculate button.

FAQs on XOR Phase Detector Phase

What is the formula to find XOR Phase Detector Phase?
The formula of XOR Phase Detector Phase is expressed as XOR Phase Detector Phase = XOR Phase Detector Voltage/XOR Phase Detector Average Voltage. Here is an example- 532.9231 = 0.5/3.08.
How to calculate XOR Phase Detector Phase?
With XOR Phase Detector Voltage (Vpd) & XOR Phase Detector Average Voltage (Kpd) we can find XOR Phase Detector Phase using the formula - XOR Phase Detector Phase = XOR Phase Detector Voltage/XOR Phase Detector Average Voltage.
What are the other ways to Calculate XOR Phase Detector Phase?
Here are the different ways to Calculate XOR Phase Detector Phase-
  • XOR Phase Detector Phase=XOR Phase Detector Current/XOR Phase Detector Average VoltageOpenImg
Can the XOR Phase Detector Phase be negative?
No, the XOR Phase Detector Phase, measured in Angle cannot be negative.
Which unit is used to measure XOR Phase Detector Phase?
XOR Phase Detector Phase is usually measured using the Degree[°] for Angle. Radian[°], Minute[°], Second[°] are the few other units in which XOR Phase Detector Phase can be measured.