Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors Formula

Fx Copy
LaTeX Copy
Worst case steady state voltage of thyristor is the voltage across thyristor 1 of the series string when ID1=0 and ΔID = ID2. Check FAQs
Vss=Vstring+Rstb(n-1)ΔIDn
Vss - Worst Case Steady State Voltage?Vstring - Resultant Series Voltage of Thyristor String?Rstb - Stablizing Resistance?n - Number of Thyristors in Series?ΔID - Off State Current Spread?

Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors Example

With values
With units
Only example

Here is how the Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors equation looks like with Values.

Here is how the Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors equation looks like with Units.

Here is how the Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors equation looks like.

113.504Edit=20.512Edit+32Edit(3Edit-1)5Edit3Edit
You are here -

Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors Solution

Follow our step by step solution on how to calculate Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors?

FIRST Step Consider the formula
Vss=Vstring+Rstb(n-1)ΔIDn
Next Step Substitute values of Variables
Vss=20.512V+32Ω(3-1)5A3
Next Step Prepare to Evaluate
Vss=20.512+32(3-1)53
LAST Step Evaluate
Vss=113.504V

Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors Formula Elements

Variables
Worst Case Steady State Voltage
Worst case steady state voltage of thyristor is the voltage across thyristor 1 of the series string when ID1=0 and ΔID = ID2.
Symbol: Vss
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Resultant Series Voltage of Thyristor String
Resultant series voltage of thyristor string is the resultant voltage of the series combination of ns number of thyristors.
Symbol: Vstring
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Stablizing Resistance
Stablizing Resistance is defined as the opposition faced by the flow of current through a thyristor based circuit which is used to stablize.
Symbol: Rstb
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Number of Thyristors in Series
Number of thyristors in series thyristor string is the quantity of thyristors in the series combination.
Symbol: n
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Off State Current Spread
Off state current spread of thyristor string is the difference between the two currents across adjacent thyristors in the string.
Symbol: ΔID
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.

Other formulas in SCR Performance Parameters category

​Go Derating Factor of Series Connected Thyristor String
DRF=1-VstringVssn
​Go Leakage Current of Collector-Base Junction
ICBO=IC-αIC
​Go Power Dissipated by Heat in SCR
Pdis=Tjunc-Tambθ
​Go Thermal Resistance of SCR
θ=Tjunc-TambPdis

How to Evaluate Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors?

Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors evaluator uses Worst Case Steady State Voltage = (Resultant Series Voltage of Thyristor String+Stablizing Resistance*(Number of Thyristors in Series-1)*Off State Current Spread)/Number of Thyristors in Series to evaluate the Worst Case Steady State Voltage, Worst case steady state voltage across first thyristor in series connected thyristors is the voltage across thyristor 1 of the series string when ID1=0 and ΔID = ID2. Worst Case Steady State Voltage is denoted by Vss symbol.

How to evaluate Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors using this online evaluator? To use this online evaluator for Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors, enter Resultant Series Voltage of Thyristor String (Vstring), Stablizing Resistance (Rstb), Number of Thyristors in Series (n) & Off State Current Spread (ΔID) and hit the calculate button.

FAQs on Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors

What is the formula to find Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors?
The formula of Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors is expressed as Worst Case Steady State Voltage = (Resultant Series Voltage of Thyristor String+Stablizing Resistance*(Number of Thyristors in Series-1)*Off State Current Spread)/Number of Thyristors in Series. Here is an example- 113.3333 = (20.512+32*(3-1)*5)/3.
How to calculate Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors?
With Resultant Series Voltage of Thyristor String (Vstring), Stablizing Resistance (Rstb), Number of Thyristors in Series (n) & Off State Current Spread (ΔID) we can find Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors using the formula - Worst Case Steady State Voltage = (Resultant Series Voltage of Thyristor String+Stablizing Resistance*(Number of Thyristors in Series-1)*Off State Current Spread)/Number of Thyristors in Series.
Can the Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors be negative?
Yes, the Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors, measured in Electric Potential can be negative.
Which unit is used to measure Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors?
Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors can be measured.
Copied!