Wind Exposure Factor given Roof Snow Load Formula

Fx Copy
LaTeX Copy
Wind Exposure Factor is the factor of effect on exposure to wind. Check FAQs
Ce=Pf0.7CtIPg
Ce - Wind Exposure Factor?Pf - Roof Snow Load?Ct - Thermal Effects Factor?I - Importance Factor for End Use?Pg - Ground Snow Load?

Wind Exposure Factor given Roof Snow Load Example

With values
With units
Only example

Here is how the Wind Exposure Factor given Roof Snow Load equation looks like with Values.

Here is how the Wind Exposure Factor given Roof Snow Load equation looks like with Units.

Here is how the Wind Exposure Factor given Roof Snow Load equation looks like.

0.9839Edit=12Edit0.71.21Edit0.8Edit18Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Structural Engineering » fx Wind Exposure Factor given Roof Snow Load

Wind Exposure Factor given Roof Snow Load Solution

Follow our step by step solution on how to calculate Wind Exposure Factor given Roof Snow Load?

FIRST Step Consider the formula
Ce=Pf0.7CtIPg
Next Step Substitute values of Variables
Ce=12psf0.71.210.818psf
Next Step Convert Units
Ce=574.5631Pa0.71.210.8861.8447Pa
Next Step Prepare to Evaluate
Ce=574.56310.71.210.8861.8447
Next Step Evaluate
Ce=0.983864620228256
LAST Step Rounding Answer
Ce=0.9839

Wind Exposure Factor given Roof Snow Load Formula Elements

Variables
Wind Exposure Factor
Wind Exposure Factor is the factor of effect on exposure to wind.
Symbol: Ce
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Roof Snow Load
Roof Snow Load is the downward force on a building's roof by the weight of accumulated snow and ice.
Symbol: Pf
Measurement: PressureUnit: psf
Note: Value should be greater than 0.
Thermal Effects Factor
The thermal Effects Factor is the measure of the effect of exposure to heat.
Symbol: Ct
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Importance Factor for End Use
Importance Factor for End Use is the factor whose value lies in range 0.8 to 1.2.
Symbol: I
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Ground Snow Load
Ground Snow Load is used in the determination of the design roof snow load of a site.
Symbol: Pg
Measurement: PressureUnit: psf
Note: Value should be greater than 0.

Other formulas in Snow Loads category

​Go Roof Snow Load
Pf=0.7CeCtIPg
​Go Thermal Effects factor given Roof Snow Load
Ct=Pf0.7CeIPg
​Go Importance Factor for End Use using Roof Snow Load
I=Pf0.7CeCtPg
​Go Ground Snow Load given Roof Snow Load
Pg=Pf0.7CeCtI

How to Evaluate Wind Exposure Factor given Roof Snow Load?

Wind Exposure Factor given Roof Snow Load evaluator uses Wind Exposure Factor = Roof Snow Load/(0.7*Thermal Effects Factor*Importance Factor for End Use*Ground Snow Load) to evaluate the Wind Exposure Factor, The Wind Exposure Factor given Roof Snow Load is defined as the wind exposure factor when we have a prior info of roof snow load. Wind Exposure Factor is denoted by Ce symbol.

How to evaluate Wind Exposure Factor given Roof Snow Load using this online evaluator? To use this online evaluator for Wind Exposure Factor given Roof Snow Load, enter Roof Snow Load (Pf), Thermal Effects Factor (Ct), Importance Factor for End Use (I) & Ground Snow Load (Pg) and hit the calculate button.

FAQs on Wind Exposure Factor given Roof Snow Load

What is the formula to find Wind Exposure Factor given Roof Snow Load?
The formula of Wind Exposure Factor given Roof Snow Load is expressed as Wind Exposure Factor = Roof Snow Load/(0.7*Thermal Effects Factor*Importance Factor for End Use*Ground Snow Load). Here is an example- 0.992063 = 574.563107758693/(0.7*1.21*0.8*861.84466163804).
How to calculate Wind Exposure Factor given Roof Snow Load?
With Roof Snow Load (Pf), Thermal Effects Factor (Ct), Importance Factor for End Use (I) & Ground Snow Load (Pg) we can find Wind Exposure Factor given Roof Snow Load using the formula - Wind Exposure Factor = Roof Snow Load/(0.7*Thermal Effects Factor*Importance Factor for End Use*Ground Snow Load).
Copied!