Width of Unit Hydrograph at 50% Peak Discharge. The role of unit hydrograph in hydrology is to provide an estimate of direct runoff hydrograph resulting from given excess rainfall hyetograph. Check FAQs
W50=W751.75
W50 - Width of Unit Hydrograph at 50% Peak Discharge?W75 - Width of Unit Hydrograph at 75% Peak Discharge?

Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge Example

With values
With units
Only example

Here is how the Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge equation looks like with Values.

Here is how the Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge equation looks like with Units.

Here is how the Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge equation looks like.

1.785Edit=1.02Edit1.75
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge

Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge Solution

Follow our step by step solution on how to calculate Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge?

FIRST Step Consider the formula
W50=W751.75
Next Step Substitute values of Variables
W50=1.02mm1.75
Next Step Convert Units
W50=0.001m1.75
Next Step Prepare to Evaluate
W50=0.0011.75
Next Step Evaluate
W50=0.001785m
LAST Step Convert to Output's Unit
W50=1.785mm

Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge Formula Elements

Variables
Width of Unit Hydrograph at 50% Peak Discharge
Width of Unit Hydrograph at 50% Peak Discharge. The role of unit hydrograph in hydrology is to provide an estimate of direct runoff hydrograph resulting from given excess rainfall hyetograph.
Symbol: W50
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Width of Unit Hydrograph at 75% Peak Discharge
Width of Unit Hydrograph at 75% Peak Discharge of unit hydrograph in hydrology is to provide an estimate of direct runoff hydrograph resulting from given excess rainfall hyetograph.
Symbol: W75
Measurement: LengthUnit: mm
Note: Value can be positive or negative.

Other Formulas to find Width of Unit Hydrograph at 50% Peak Discharge

​Go Width of Unit Hydrograph at 50 percent Peak Discharge
W50=5.87Q1.08

Other formulas in Synder's Synthetic Unit Hydrograph category

​Go Peak Discharge for Nonstandard Effective Rainfall
Qp=2.78CpAt'p
​Go Regional Constant given Peak Discharge for Nonstandard Effective Rainfall
Cp=Qpt'p2.78A
​Go Catchment Area given Peak Discharge for Nonstandard Effective Rainfall
A=Qpt'p2.78Cr
​Go Modified Basin Lag given Peak Discharge for Nonstandard Effective Rainfall
t'p=2.78CrAQp

How to Evaluate Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge?

Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge evaluator uses Width of Unit Hydrograph at 50% Peak Discharge = Width of Unit Hydrograph at 75% Peak Discharge*1.75 to evaluate the Width of Unit Hydrograph at 50% Peak Discharge, The Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge formula is defined as the geometric parameter of the unit hydrograph correlated to the peak discharge intensity, found to assist in the sketching of unit hydrographs. Width of Unit Hydrograph at 50% Peak Discharge is denoted by W50 symbol.

How to evaluate Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge using this online evaluator? To use this online evaluator for Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge, enter Width of Unit Hydrograph at 75% Peak Discharge (W75) and hit the calculate button.

FAQs on Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge

What is the formula to find Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge?
The formula of Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge is expressed as Width of Unit Hydrograph at 50% Peak Discharge = Width of Unit Hydrograph at 75% Peak Discharge*1.75. Here is an example- 1785 = 0.00102*1.75.
How to calculate Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge?
With Width of Unit Hydrograph at 75% Peak Discharge (W75) we can find Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge using the formula - Width of Unit Hydrograph at 50% Peak Discharge = Width of Unit Hydrograph at 75% Peak Discharge*1.75.
What are the other ways to Calculate Width of Unit Hydrograph at 50% Peak Discharge?
Here are the different ways to Calculate Width of Unit Hydrograph at 50% Peak Discharge-
  • Width of Unit Hydrograph at 50% Peak Discharge=5.87/Discharge^1.08OpenImg
Can the Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge be negative?
No, the Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge, measured in Length cannot be negative.
Which unit is used to measure Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge?
Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge is usually measured using the Millimeter[mm] for Length. Meter[mm], Kilometer[mm], Decimeter[mm] are the few other units in which Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge can be measured.