Width of Unit Hydrograph at 50% Peak Discharge. The role of unit hydrograph in hydrology is to provide an estimate of direct runoff hydrograph resulting from given excess rainfall hyetograph. Check FAQs
W50=5.87Q1.08
W50 - Width of Unit Hydrograph at 50% Peak Discharge?Q - Discharge?

Width of Unit Hydrograph at 50 percent Peak Discharge Example

With values
With units
Only example

Here is how the Width of Unit Hydrograph at 50 percent Peak Discharge equation looks like with Values.

Here is how the Width of Unit Hydrograph at 50 percent Peak Discharge equation looks like with Units.

Here is how the Width of Unit Hydrograph at 50 percent Peak Discharge equation looks like.

1.792Edit=5.873Edit1.08
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Width of Unit Hydrograph at 50 percent Peak Discharge

Width of Unit Hydrograph at 50 percent Peak Discharge Solution

Follow our step by step solution on how to calculate Width of Unit Hydrograph at 50 percent Peak Discharge?

FIRST Step Consider the formula
W50=5.87Q1.08
Next Step Substitute values of Variables
W50=5.873m³/s1.08
Next Step Prepare to Evaluate
W50=5.8731.08
Next Step Evaluate
W50=0.001792037717563m
Next Step Convert to Output's Unit
W50=1.792037717563mm
LAST Step Rounding Answer
W50=1.792mm

Width of Unit Hydrograph at 50 percent Peak Discharge Formula Elements

Variables
Width of Unit Hydrograph at 50% Peak Discharge
Width of Unit Hydrograph at 50% Peak Discharge. The role of unit hydrograph in hydrology is to provide an estimate of direct runoff hydrograph resulting from given excess rainfall hyetograph.
Symbol: W50
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Discharge
The Discharge refers to the volumetric flow rate of water that is transported through a given cross-sectional area. It includes any suspended solids, dissolved chemicals, or biologic material.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.

Other Formulas to find Width of Unit Hydrograph at 50% Peak Discharge

​Go Width of Unit Hydrograph at 50 percent Peak Discharge given 75 percent Discharge
W50=W751.75

Other formulas in Synder's Synthetic Unit Hydrograph category

​Go Peak Discharge for Nonstandard Effective Rainfall
Qp=2.78CpAt'p
​Go Regional Constant given Peak Discharge for Nonstandard Effective Rainfall
Cp=Qpt'p2.78A
​Go Catchment Area given Peak Discharge for Nonstandard Effective Rainfall
A=Qpt'p2.78Cr
​Go Modified Basin Lag given Peak Discharge for Nonstandard Effective Rainfall
t'p=2.78CrAQp

How to Evaluate Width of Unit Hydrograph at 50 percent Peak Discharge?

Width of Unit Hydrograph at 50 percent Peak Discharge evaluator uses Width of Unit Hydrograph at 50% Peak Discharge = 5.87/Discharge^1.08 to evaluate the Width of Unit Hydrograph at 50% Peak Discharge, The Width of Unit Hydrograph at 50 percent Peak Discharge formula is defined as the geometric parameter of the unit hydrograph correlated to the peak discharge intensity. Width of Unit Hydrograph at 50% Peak Discharge is denoted by W50 symbol.

How to evaluate Width of Unit Hydrograph at 50 percent Peak Discharge using this online evaluator? To use this online evaluator for Width of Unit Hydrograph at 50 percent Peak Discharge, enter Discharge (Q) and hit the calculate button.

FAQs on Width of Unit Hydrograph at 50 percent Peak Discharge

What is the formula to find Width of Unit Hydrograph at 50 percent Peak Discharge?
The formula of Width of Unit Hydrograph at 50 percent Peak Discharge is expressed as Width of Unit Hydrograph at 50% Peak Discharge = 5.87/Discharge^1.08. Here is an example- 1792.038 = 5.87/3^1.08.
How to calculate Width of Unit Hydrograph at 50 percent Peak Discharge?
With Discharge (Q) we can find Width of Unit Hydrograph at 50 percent Peak Discharge using the formula - Width of Unit Hydrograph at 50% Peak Discharge = 5.87/Discharge^1.08.
What are the other ways to Calculate Width of Unit Hydrograph at 50% Peak Discharge?
Here are the different ways to Calculate Width of Unit Hydrograph at 50% Peak Discharge-
  • Width of Unit Hydrograph at 50% Peak Discharge=Width of Unit Hydrograph at 75% Peak Discharge*1.75OpenImg
Can the Width of Unit Hydrograph at 50 percent Peak Discharge be negative?
No, the Width of Unit Hydrograph at 50 percent Peak Discharge, measured in Length cannot be negative.
Which unit is used to measure Width of Unit Hydrograph at 50 percent Peak Discharge?
Width of Unit Hydrograph at 50 percent Peak Discharge is usually measured using the Millimeter[mm] for Length. Meter[mm], Kilometer[mm], Decimeter[mm] are the few other units in which Width of Unit Hydrograph at 50 percent Peak Discharge can be measured.
Copied!