Fx Copy
LaTeX Copy
Width is the horizontal measurement or dimension of a structure, feature, or area. Check FAQs
w=70Qs100Lvs
w - Width?Qs - Discharge entering Basin given Settling Velocity?L - Length?vs - Settling Velocity?

Width of Tank given Settling Velocity of Particular Sized Particle Example

With values
With units
Only example

Here is how the Width of Tank given Settling Velocity of Particular Sized Particle equation looks like with Values.

Here is how the Width of Tank given Settling Velocity of Particular Sized Particle equation looks like with Units.

Here is how the Width of Tank given Settling Velocity of Particular Sized Particle equation looks like.

1.6029Edit=7010.339Edit1003.01Edit1.5Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Width of Tank given Settling Velocity of Particular Sized Particle

Width of Tank given Settling Velocity of Particular Sized Particle Solution

Follow our step by step solution on how to calculate Width of Tank given Settling Velocity of Particular Sized Particle?

FIRST Step Consider the formula
w=70Qs100Lvs
Next Step Substitute values of Variables
w=7010.339m³/s1003.01m1.5m/s
Next Step Prepare to Evaluate
w=7010.3391003.011.5
Next Step Evaluate
w=1.60294573643411m
LAST Step Rounding Answer
w=1.6029m

Width of Tank given Settling Velocity of Particular Sized Particle Formula Elements

Variables
Width
Width is the horizontal measurement or dimension of a structure, feature, or area.
Symbol: w
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Discharge entering Basin given Settling Velocity
Discharge entering Basin given Settling Velocity is the volumetric flow rate of water that enters a sedimentation basin, calculated based on the settling velocity.
Symbol: Qs
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Length
Length is the measurement or extent of something from end to end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Settling Velocity
Settling Velocity is defined as the terminal velocity of a particle in still fluid.
Symbol: vs
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.

Other Formulas to find Width

​Go Width of Tank given Flow Velocity
w=(QvVfd)
​Go Width of Tank given Settling Velocity
w=(QsvsL)
​Go Width of Tank given Height to Length Ratio
w=(Qvsd)(HL)
​Go Width of Tank given Overflow Rate
w=(QSORL)

How to Evaluate Width of Tank given Settling Velocity of Particular Sized Particle?

Width of Tank given Settling Velocity of Particular Sized Particle evaluator uses Width = (70*Discharge entering Basin given Settling Velocity)/(100*Length*Settling Velocity) to evaluate the Width, The Width of Tank given Settling Velocity of Particular Sized Particle formula is defined as the horizontal dimension of a tank or reservoir, considering setting velocity of particular sized particle. Width is denoted by w symbol.

How to evaluate Width of Tank given Settling Velocity of Particular Sized Particle using this online evaluator? To use this online evaluator for Width of Tank given Settling Velocity of Particular Sized Particle, enter Discharge entering Basin given Settling Velocity (Qs), Length (L) & Settling Velocity (vs) and hit the calculate button.

FAQs on Width of Tank given Settling Velocity of Particular Sized Particle

What is the formula to find Width of Tank given Settling Velocity of Particular Sized Particle?
The formula of Width of Tank given Settling Velocity of Particular Sized Particle is expressed as Width = (70*Discharge entering Basin given Settling Velocity)/(100*Length*Settling Velocity). Here is an example- 1.602946 = (70*10.339)/(100*3.01*1.5).
How to calculate Width of Tank given Settling Velocity of Particular Sized Particle?
With Discharge entering Basin given Settling Velocity (Qs), Length (L) & Settling Velocity (vs) we can find Width of Tank given Settling Velocity of Particular Sized Particle using the formula - Width = (70*Discharge entering Basin given Settling Velocity)/(100*Length*Settling Velocity).
What are the other ways to Calculate Width?
Here are the different ways to Calculate Width-
  • Width=(Discharge entering Basin given Flow Velocity/(Flow Velocity*Depth))OpenImg
  • Width=(Discharge entering Basin given Settling Velocity/(Settling Velocity*Length))OpenImg
  • Width=(Discharge/(Settling Velocity*Depth))*(Ratio of Height to Length)OpenImg
Can the Width of Tank given Settling Velocity of Particular Sized Particle be negative?
Yes, the Width of Tank given Settling Velocity of Particular Sized Particle, measured in Length can be negative.
Which unit is used to measure Width of Tank given Settling Velocity of Particular Sized Particle?
Width of Tank given Settling Velocity of Particular Sized Particle is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Width of Tank given Settling Velocity of Particular Sized Particle can be measured.
Copied!