Width of Footing is the shorter dimension of the footing. Check FAQs
B=qfc-(σsNq)0.5Nγγ
B - Width of Footing?qfc - Ultimate Bearing Capacity in Soil?σs - Effective Surcharge in KiloPascal?Nq - Bearing Capacity Factor dependent on Surcharge?Nγ - Bearing Capacity Factor dependent on Unit Weight?γ - Unit Weight of Soil?

Width of Strip Footing given Bearing Capacity Example

With values
With units
Only example

Here is how the Width of Strip Footing given Bearing Capacity equation looks like with Values.

Here is how the Width of Strip Footing given Bearing Capacity equation looks like with Units.

Here is how the Width of Strip Footing given Bearing Capacity equation looks like.

2.4681Edit=127.8Edit-(45.9Edit2.01Edit)0.51.6Edit18Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Geotechnical Engineering » fx Width of Strip Footing given Bearing Capacity

Width of Strip Footing given Bearing Capacity Solution

Follow our step by step solution on how to calculate Width of Strip Footing given Bearing Capacity?

FIRST Step Consider the formula
B=qfc-(σsNq)0.5Nγγ
Next Step Substitute values of Variables
B=127.8kPa-(45.9kN/m²2.01)0.51.618kN/m³
Next Step Convert Units
B=127800Pa-(45900Pa2.01)0.51.618000N/m³
Next Step Prepare to Evaluate
B=127800-(459002.01)0.51.618000
Next Step Evaluate
B=2.468125m
LAST Step Rounding Answer
B=2.4681m

Width of Strip Footing given Bearing Capacity Formula Elements

Variables
Width of Footing
Width of Footing is the shorter dimension of the footing.
Symbol: B
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Ultimate Bearing Capacity in Soil
Ultimate Bearing Capacity in Soil is defined as the minimum gross pressure intensity at the base of the foundation at which the soil fails in shear.
Symbol: qfc
Measurement: PressureUnit: kPa
Note: Value should be greater than 0.
Effective Surcharge in KiloPascal
Effective Surcharge in KiloPascal also called as surcharge load refers to the vertical pressure or any load that acts over the ground surface additional to basic earth pressure.
Symbol: σs
Measurement: PressureUnit: kN/m²
Note: Value should be greater than 0.
Bearing Capacity Factor dependent on Surcharge
Bearing Capacity Factor dependent on Surcharge is a constant whose value depends upon surcharge.
Symbol: Nq
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Bearing Capacity Factor dependent on Unit Weight
Bearing Capacity Factor dependent on Unit Weight is a constant whose value depends upon unit weight of soil.
Symbol: Nγ
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Unit Weight of Soil
Unit Weight of Soil mass is the ratio of the total weight of soil to the total volume of soil.
Symbol: γ
Measurement: Specific WeightUnit: kN/m³
Note: Value should be greater than 0.

Other Formulas to find Width of Footing

​Go Width of Square Footing given Bearing Capacity
B=qfc-(σsNq)0.4Nγγ

Other formulas in Bearing Capacity of Non cohesive Soil category

​Go Bearing Capacity of Non Cohesive Soil for Strip Footing
qfc=(σsNq)+(0.5γBNγ)
​Go Effective Surcharge given Bearing Capacity of Non Cohesive Soil for Strip Footing
σs=qfc-(0.5γBNγ)Nq
​Go Bearing Capacity Factor Dependent on Surcharge for Strip Footing
Nq=qfc-(0.5γBNγ)σs
​Go Bearing Capacity Factor Dependent on Unit Weight for Strip Footing
Nγ=qfc-(σsNq)0.5γB

How to Evaluate Width of Strip Footing given Bearing Capacity?

Width of Strip Footing given Bearing Capacity evaluator uses Width of Footing = (Ultimate Bearing Capacity in Soil-(Effective Surcharge in KiloPascal*Bearing Capacity Factor dependent on Surcharge))/(0.5*Bearing Capacity Factor dependent on Unit Weight*Unit Weight of Soil) to evaluate the Width of Footing, The Width of Strip Footing given Bearing Capacity is defined as the value of width of footing when we have prior information of other parameters used. Width of Footing is denoted by B symbol.

How to evaluate Width of Strip Footing given Bearing Capacity using this online evaluator? To use this online evaluator for Width of Strip Footing given Bearing Capacity, enter Ultimate Bearing Capacity in Soil (qfc), Effective Surcharge in KiloPascal s), Bearing Capacity Factor dependent on Surcharge (Nq), Bearing Capacity Factor dependent on Unit Weight (Nγ) & Unit Weight of Soil (γ) and hit the calculate button.

FAQs on Width of Strip Footing given Bearing Capacity

What is the formula to find Width of Strip Footing given Bearing Capacity?
The formula of Width of Strip Footing given Bearing Capacity is expressed as Width of Footing = (Ultimate Bearing Capacity in Soil-(Effective Surcharge in KiloPascal*Bearing Capacity Factor dependent on Surcharge))/(0.5*Bearing Capacity Factor dependent on Unit Weight*Unit Weight of Soil). Here is an example- 2.5 = (127800-(45900*2.01))/(0.5*1.6*18000).
How to calculate Width of Strip Footing given Bearing Capacity?
With Ultimate Bearing Capacity in Soil (qfc), Effective Surcharge in KiloPascal s), Bearing Capacity Factor dependent on Surcharge (Nq), Bearing Capacity Factor dependent on Unit Weight (Nγ) & Unit Weight of Soil (γ) we can find Width of Strip Footing given Bearing Capacity using the formula - Width of Footing = (Ultimate Bearing Capacity in Soil-(Effective Surcharge in KiloPascal*Bearing Capacity Factor dependent on Surcharge))/(0.5*Bearing Capacity Factor dependent on Unit Weight*Unit Weight of Soil).
What are the other ways to Calculate Width of Footing?
Here are the different ways to Calculate Width of Footing-
  • Width of Footing=(Ultimate Bearing Capacity in Soil-(Effective Surcharge in KiloPascal*Bearing Capacity Factor dependent on Surcharge))/(0.4*Bearing Capacity Factor dependent on Unit Weight*Unit Weight of Soil)OpenImg
Can the Width of Strip Footing given Bearing Capacity be negative?
No, the Width of Strip Footing given Bearing Capacity, measured in Length cannot be negative.
Which unit is used to measure Width of Strip Footing given Bearing Capacity?
Width of Strip Footing given Bearing Capacity is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Width of Strip Footing given Bearing Capacity can be measured.
Copied!