Fx Copy
LaTeX Copy
The Width of Settling Zone refers to the dimension that determines how much space is available for particles to settle out of a fluid. Check FAQs
W=HQLhv'
W - Width of Settling Zone?H - Outer Height?Q - Discharge?L - Length?h - Height of Crack?v' - Falling Speed?

Width of Settling Zone given Height at Outlet Zone with respect to Discharge Example

With values
With units
Only example

Here is how the Width of Settling Zone given Height at Outlet Zone with respect to Discharge equation looks like with Values.

Here is how the Width of Settling Zone given Height at Outlet Zone with respect to Discharge equation looks like with Units.

Here is how the Width of Settling Zone given Height at Outlet Zone with respect to Discharge equation looks like.

2.8056Edit=40Edit1.01Edit12Edit12000Edit0.1Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Width of Settling Zone given Height at Outlet Zone with respect to Discharge

Width of Settling Zone given Height at Outlet Zone with respect to Discharge Solution

Follow our step by step solution on how to calculate Width of Settling Zone given Height at Outlet Zone with respect to Discharge?

FIRST Step Consider the formula
W=HQLhv'
Next Step Substitute values of Variables
W=40m1.01m³/s12m12000mm0.1m/s
Next Step Convert Units
W=40m1.01m³/s12m12m0.1m/s
Next Step Prepare to Evaluate
W=401.0112120.1
Next Step Evaluate
W=2.80555555555556J/kg
LAST Step Rounding Answer
W=2.8056J/kg

Width of Settling Zone given Height at Outlet Zone with respect to Discharge Formula Elements

Variables
Width of Settling Zone
The Width of Settling Zone refers to the dimension that determines how much space is available for particles to settle out of a fluid.
Symbol: W
Measurement: Latent HeatUnit: J/kg
Note: Value can be positive or negative.
Outer Height
The Outer Height refers to the external vertical dimension of an object or structure.
Symbol: H
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Discharge
The Discharge refers to the volume of fluid (usually water) that flows through a given cross-sectional area per unit of time.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Length
The Length refers to the measurement of the distance between two points.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Height of Crack
The Height of Crack refers to the size of a flaw or crack in a material that can lead to catastrophic failure under a given stress.
Symbol: h
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Falling Speed
The Falling Speed refers to the constant speed at which a particle falls through a fluid when the force of gravity is balanced by the drag force and buoyant force acting on the particle.
Symbol: v'
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.

Other Formulas to find Width of Settling Zone

​Go Width of Settling Zone given Detention Time
W=TdQLh
​Go Width of Settling Zone given Surface Area of Sedimentation Tank
W=AL
​Go Width of Settling Zone given Cross-section Area of Sedimentation Tank
W=Acsh

How to Evaluate Width of Settling Zone given Height at Outlet Zone with respect to Discharge?

Width of Settling Zone given Height at Outlet Zone with respect to Discharge evaluator uses Width of Settling Zone = Outer Height*Discharge/(Length*Height of Crack*Falling Speed) to evaluate the Width of Settling Zone, The Width of Settling Zone given Height at Outlet Zone with respect to Discharge formlua is defined as the horizontal distance over which particles settle out of the fluid. This zone is a crucial part of the sedimentation process in water and wastewater treatment, as it allows for the removal of suspended solids through gravity settling. Width of Settling Zone is denoted by W symbol.

How to evaluate Width of Settling Zone given Height at Outlet Zone with respect to Discharge using this online evaluator? To use this online evaluator for Width of Settling Zone given Height at Outlet Zone with respect to Discharge, enter Outer Height (H), Discharge (Q), Length (L), Height of Crack (h) & Falling Speed (v') and hit the calculate button.

FAQs on Width of Settling Zone given Height at Outlet Zone with respect to Discharge

What is the formula to find Width of Settling Zone given Height at Outlet Zone with respect to Discharge?
The formula of Width of Settling Zone given Height at Outlet Zone with respect to Discharge is expressed as Width of Settling Zone = Outer Height*Discharge/(Length*Height of Crack*Falling Speed). Here is an example- 2.805556 = 40*1.01/(12*12*0.1).
How to calculate Width of Settling Zone given Height at Outlet Zone with respect to Discharge?
With Outer Height (H), Discharge (Q), Length (L), Height of Crack (h) & Falling Speed (v') we can find Width of Settling Zone given Height at Outlet Zone with respect to Discharge using the formula - Width of Settling Zone = Outer Height*Discharge/(Length*Height of Crack*Falling Speed).
What are the other ways to Calculate Width of Settling Zone?
Here are the different ways to Calculate Width of Settling Zone-
  • Width of Settling Zone=(Detention Time*Discharge)/(Length*Height of Crack)OpenImg
  • Width of Settling Zone=Area/LengthOpenImg
  • Width of Settling Zone=Cross-Sectional Area/Height of CrackOpenImg
Can the Width of Settling Zone given Height at Outlet Zone with respect to Discharge be negative?
Yes, the Width of Settling Zone given Height at Outlet Zone with respect to Discharge, measured in Latent Heat can be negative.
Which unit is used to measure Width of Settling Zone given Height at Outlet Zone with respect to Discharge?
Width of Settling Zone given Height at Outlet Zone with respect to Discharge is usually measured using the Joule per Kilogram[J/kg] for Latent Heat. Kilojoule per Kilogram[J/kg], BTU per Pound[J/kg], Calorie per Gram[J/kg] are the few other units in which Width of Settling Zone given Height at Outlet Zone with respect to Discharge can be measured.
Copied!