Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness Formula

Fx Copy
LaTeX Copy
Width of Projection of Flange is width projected outwarded from flange. Check FAQs
b'=65tffy
b' - Width of Projection of Flange?tf - Flange Minimum Thickness?fy - Yield Strength of Steel?

Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness Example

With values
With units
Only example

Here is how the Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness equation looks like with Values.

Here is how the Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness equation looks like with Units.

Here is how the Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness equation looks like.

1.2086Edit=65294Edit250Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Bridge and Suspension Cable » fx Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness

Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness Solution

Follow our step by step solution on how to calculate Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness?

FIRST Step Consider the formula
b'=65tffy
Next Step Substitute values of Variables
b'=65294mm250MPa
Next Step Convert Units
b'=650.294m2.5E+8Pa
Next Step Prepare to Evaluate
b'=650.2942.5E+8
Next Step Evaluate
b'=0.00120862252171635m
Next Step Convert to Output's Unit
b'=1.20862252171635mm
LAST Step Rounding Answer
b'=1.2086mm

Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness Formula Elements

Variables
Functions
Width of Projection of Flange
Width of Projection of Flange is width projected outwarded from flange.
Symbol: b'
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Flange Minimum Thickness
Flange Minimum Thickness is the minimum thickness of the plates used in the flange.
Symbol: tf
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Yield Strength of Steel
Yield strength of steel is the level of stress that corresponds to the yield point.
Symbol: fy
Measurement: StressUnit: MPa
Note: Value should be greater than 0.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other formulas in Load Factor Design for Bridge Beams category

​Go Maximum Bending Strength for Symmetrical Flexural Compact Section for LFD of Bridges
Mu=fyZ
​Go Maximum Bending Strength for Symmetrical Flexural Braced Non-Compacted Section for LFD of Bridges
Mu=fyS
​Go Minimum Flange Thickness for Symmetrical Flexural Compact Section for LFD of Bridges
tf=b'fy65
​Go Minimum Flange Thickness for Symmetrical Flexural Braced Non-Compact Section for LFD of Bridges
tf=b'fy69.6

How to Evaluate Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness?

Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness evaluator uses Width of Projection of Flange = (65*Flange Minimum Thickness)/(sqrt(Yield Strength of Steel)) to evaluate the Width of Projection of Flange, Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness formula is defined as width of outstanding leg of member. Width of Projection of Flange is denoted by b' symbol.

How to evaluate Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness using this online evaluator? To use this online evaluator for Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness, enter Flange Minimum Thickness (tf) & Yield Strength of Steel (fy) and hit the calculate button.

FAQs on Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness

What is the formula to find Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness?
The formula of Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness is expressed as Width of Projection of Flange = (65*Flange Minimum Thickness)/(sqrt(Yield Strength of Steel)). Here is an example- 1208.623 = (65*0.294)/(sqrt(250000000)).
How to calculate Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness?
With Flange Minimum Thickness (tf) & Yield Strength of Steel (fy) we can find Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness using the formula - Width of Projection of Flange = (65*Flange Minimum Thickness)/(sqrt(Yield Strength of Steel)). This formula also uses Square Root (sqrt) function(s).
Can the Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness be negative?
No, the Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness, measured in Length cannot be negative.
Which unit is used to measure Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness?
Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness is usually measured using the Millimeter[mm] for Length. Meter[mm], Kilometer[mm], Decimeter[mm] are the few other units in which Width of Projection of Flange for Compact Section for LFD given Minimum Flange Thickness can be measured.
Copied!