Width of Footing given Strip Footing and Bearing Capacity Formula

Fx Copy
LaTeX Copy
Width of Footing for Strip Footing is the shorter dimension of the strip footing. Check FAQs
Bstrip=qf-((1CNc)+(σ'Nq))0.5Nγγ1
Bstrip - Width of Footing for Strip Footing?qf - Ultimate Bearing Capacity?C - Cohesion?Nc - Bearing Capacity Factor dependent on Cohesion?σ' - Effective Surcharge?Nq - Bearing Capacity Factor dependent on Surcharge?Nγ - Bearing Capacity Factor dependent on Unit Weight?γ - Unit Weight of Soil?

Width of Footing given Strip Footing and Bearing Capacity Example

With values
With units
Only example

Here is how the Width of Footing given Strip Footing and Bearing Capacity equation looks like with Values.

Here is how the Width of Footing given Strip Footing and Bearing Capacity equation looks like with Units.

Here is how the Width of Footing given Strip Footing and Bearing Capacity equation looks like.

3.5983Edit=60Edit-((14.23Edit1.93Edit)+(10Edit2.01Edit))0.51.6Edit18Edit1
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Geotechnical Engineering » fx Width of Footing given Strip Footing and Bearing Capacity

Width of Footing given Strip Footing and Bearing Capacity Solution

Follow our step by step solution on how to calculate Width of Footing given Strip Footing and Bearing Capacity?

FIRST Step Consider the formula
Bstrip=qf-((1CNc)+(σ'Nq))0.5Nγγ1
Next Step Substitute values of Variables
Bstrip=60kPa-((14.23kPa1.93)+(10Pa2.01))0.51.618kN/m³1
Next Step Convert Units
Bstrip=60000Pa-((14230Pa1.93)+(10Pa2.01))0.51.618000N/m³1
Next Step Prepare to Evaluate
Bstrip=60000-((142301.93)+(102.01))0.51.6180001
Next Step Evaluate
Bstrip=3.59833333333333m
LAST Step Rounding Answer
Bstrip=3.5983m

Width of Footing given Strip Footing and Bearing Capacity Formula Elements

Variables
Width of Footing for Strip Footing
Width of Footing for Strip Footing is the shorter dimension of the strip footing.
Symbol: Bstrip
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Ultimate Bearing Capacity
The Ultimate Bearing Capacity is defined as the minimum gross pressure intensity at the base of the foundation at which the soil fails in shear.
Symbol: qf
Measurement: PressureUnit: kPa
Note: Value should be greater than 0.
Cohesion
Cohesion is the ability of like particles within soil to hold onto each other. It is the shear strength or force that binds together like particles in the structure of a soil.
Symbol: C
Measurement: PressureUnit: kPa
Note: Value should be between 0 to 50.
Bearing Capacity Factor dependent on Cohesion
Bearing Capacity Factor dependent on Cohesion is a constant whose value depends upon the cohesion of soil.
Symbol: Nc
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Effective Surcharge
Effective Surcharge also called as surcharge load refers to the vertical pressure or any load that acts over the ground surface additional to basic earth pressure.
Symbol: σ'
Measurement: PressureUnit: Pa
Note: Value should be greater than 0.
Bearing Capacity Factor dependent on Surcharge
Bearing Capacity Factor dependent on Surcharge is a constant whose value depends upon surcharge.
Symbol: Nq
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Bearing Capacity Factor dependent on Unit Weight
Bearing Capacity Factor dependent on Unit Weight is a constant whose value depends upon unit weight of soil.
Symbol: Nγ
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Unit Weight of Soil
Unit Weight of Soil mass is the ratio of the total weight of soil to the total volume of soil.
Symbol: γ
Measurement: Specific WeightUnit: kN/m³
Note: Value should be greater than 0.

Other formulas in Specialization of Terzaghi's Equations category

​Go Bearing Capacity depending on Shape Factors
qs=(scCNc)+(σsNq)+(0.5γBNγsγ)
​Go Cohesion of Soil depending on Shape Factors
C=qf-((σ'Nq)+(0.5γBNγsγ))scNc

How to Evaluate Width of Footing given Strip Footing and Bearing Capacity?

Width of Footing given Strip Footing and Bearing Capacity evaluator uses Width of Footing for Strip Footing = (Ultimate Bearing Capacity-((1*Cohesion*Bearing Capacity Factor dependent on Cohesion)+(Effective Surcharge*Bearing Capacity Factor dependent on Surcharge)))/(0.5*Bearing Capacity Factor dependent on Unit Weight*Unit Weight of Soil*1) to evaluate the Width of Footing for Strip Footing, The Width of Footing given Strip Footing and Bearing Capacity formula is defined as the value of width of footing when we have prior information of other parameters used for strip footing. Width of Footing for Strip Footing is denoted by Bstrip symbol.

How to evaluate Width of Footing given Strip Footing and Bearing Capacity using this online evaluator? To use this online evaluator for Width of Footing given Strip Footing and Bearing Capacity, enter Ultimate Bearing Capacity (qf), Cohesion (C), Bearing Capacity Factor dependent on Cohesion (Nc), Effective Surcharge (σ'), Bearing Capacity Factor dependent on Surcharge (Nq), Bearing Capacity Factor dependent on Unit Weight (Nγ) & Unit Weight of Soil (γ) and hit the calculate button.

FAQs on Width of Footing given Strip Footing and Bearing Capacity

What is the formula to find Width of Footing given Strip Footing and Bearing Capacity?
The formula of Width of Footing given Strip Footing and Bearing Capacity is expressed as Width of Footing for Strip Footing = (Ultimate Bearing Capacity-((1*Cohesion*Bearing Capacity Factor dependent on Cohesion)+(Effective Surcharge*Bearing Capacity Factor dependent on Surcharge)))/(0.5*Bearing Capacity Factor dependent on Unit Weight*Unit Weight of Soil*1). Here is an example- 3.598333 = (60000-((1*4230*1.93)+(10*2.01)))/(0.5*1.6*18000*1).
How to calculate Width of Footing given Strip Footing and Bearing Capacity?
With Ultimate Bearing Capacity (qf), Cohesion (C), Bearing Capacity Factor dependent on Cohesion (Nc), Effective Surcharge (σ'), Bearing Capacity Factor dependent on Surcharge (Nq), Bearing Capacity Factor dependent on Unit Weight (Nγ) & Unit Weight of Soil (γ) we can find Width of Footing given Strip Footing and Bearing Capacity using the formula - Width of Footing for Strip Footing = (Ultimate Bearing Capacity-((1*Cohesion*Bearing Capacity Factor dependent on Cohesion)+(Effective Surcharge*Bearing Capacity Factor dependent on Surcharge)))/(0.5*Bearing Capacity Factor dependent on Unit Weight*Unit Weight of Soil*1).
Can the Width of Footing given Strip Footing and Bearing Capacity be negative?
No, the Width of Footing given Strip Footing and Bearing Capacity, measured in Length cannot be negative.
Which unit is used to measure Width of Footing given Strip Footing and Bearing Capacity?
Width of Footing given Strip Footing and Bearing Capacity is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Width of Footing given Strip Footing and Bearing Capacity can be measured.
Copied!