Wetted Perimeter given Reynolds Number of Film Formula

Fx Copy
LaTeX Copy
Wetted Perimeter is defined as the surface of the channel bottom and sides in direct contact with the aqueous body. Check FAQs
P=41Refμ
P - Wetted Perimeter?1 - Mass Flow of Condensate?Ref - Reynolds Number of Film?μ - Viscosity of Fluid?

Wetted Perimeter given Reynolds Number of Film Example

With values
With units
Only example

Here is how the Wetted Perimeter given Reynolds Number of Film equation looks like with Values.

Here is how the Wetted Perimeter given Reynolds Number of Film equation looks like with Units.

Here is how the Wetted Perimeter given Reynolds Number of Film equation looks like.

9.6Edit=47200Edit300Edit10Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Heat Transfer » fx Wetted Perimeter given Reynolds Number of Film

Wetted Perimeter given Reynolds Number of Film Solution

Follow our step by step solution on how to calculate Wetted Perimeter given Reynolds Number of Film?

FIRST Step Consider the formula
P=41Refμ
Next Step Substitute values of Variables
P=47200kg/s30010N*s/m²
Next Step Convert Units
P=47200kg/s30010Pa*s
Next Step Prepare to Evaluate
P=4720030010
LAST Step Evaluate
P=9.6m

Wetted Perimeter given Reynolds Number of Film Formula Elements

Variables
Wetted Perimeter
Wetted Perimeter is defined as the surface of the channel bottom and sides in direct contact with the aqueous body.
Symbol: P
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Mass Flow of Condensate
Mass Flow of Condensate is the mass of a condensate which passes per unit of time.
Symbol: 1
Measurement: Mass Flow RateUnit: kg/s
Note: Value should be greater than 0.
Reynolds Number of Film
Reynolds Number of Film is the ratio of Inertial force to the viscous force.
Symbol: Ref
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Viscosity of Fluid
The Viscosity of fluid is a measure of its resistance to deformation at a given rate.
Symbol: μ
Measurement: Dynamic ViscosityUnit: N*s/m²
Note: Value can be positive or negative.

Other formulas in Condensation category

​Go Film Thickness given Mass Flow of Condensate
δ=(3μfρL(ρL-ρv)[g])13
​Go Condensation Number
Co=(h ̅)(((μf)2(k3)(ρf)(ρf-ρv)[g])13)
​Go Condensation Number for Vertical Plate
Co=1.47((Ref)-13)
​Go Condensation Number for Horizontal Cylinder
Co=1.514((Ref)-13)

How to Evaluate Wetted Perimeter given Reynolds Number of Film?

Wetted Perimeter given Reynolds Number of Film evaluator uses Wetted Perimeter = (4*Mass Flow of Condensate)/(Reynolds Number of Film*Viscosity of Fluid) to evaluate the Wetted Perimeter, The Wetted Perimeter given Reynolds Number of Film formula is defined as the function of mass flow rate of condensate, Reynolds number of film, viscosity of fluid. In filmwise condensation a laminar film of vapor is created upon a surface. This film can then flow downwards, increasing in thickness as additional vapor is picked up along the way . In dropwise condensation vapor droplets form at an acute angle to a surface. Wetted Perimeter is denoted by P symbol.

How to evaluate Wetted Perimeter given Reynolds Number of Film using this online evaluator? To use this online evaluator for Wetted Perimeter given Reynolds Number of Film, enter Mass Flow of Condensate (ṁ1), Reynolds Number of Film (Ref) & Viscosity of Fluid (μ) and hit the calculate button.

FAQs on Wetted Perimeter given Reynolds Number of Film

What is the formula to find Wetted Perimeter given Reynolds Number of Film?
The formula of Wetted Perimeter given Reynolds Number of Film is expressed as Wetted Perimeter = (4*Mass Flow of Condensate)/(Reynolds Number of Film*Viscosity of Fluid). Here is an example- 9.6 = (4*7200)/(300*10).
How to calculate Wetted Perimeter given Reynolds Number of Film?
With Mass Flow of Condensate (ṁ1), Reynolds Number of Film (Ref) & Viscosity of Fluid (μ) we can find Wetted Perimeter given Reynolds Number of Film using the formula - Wetted Perimeter = (4*Mass Flow of Condensate)/(Reynolds Number of Film*Viscosity of Fluid).
Can the Wetted Perimeter given Reynolds Number of Film be negative?
Yes, the Wetted Perimeter given Reynolds Number of Film, measured in Length can be negative.
Which unit is used to measure Wetted Perimeter given Reynolds Number of Film?
Wetted Perimeter given Reynolds Number of Film is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Wetted Perimeter given Reynolds Number of Film can be measured.
Copied!