Fx Copy
LaTeX Copy
Wet Bulb Temperature is the temperature of the wet bulb and denoted by the symbol Tw. Check FAQs
Tw=T∞-(hfg(Pw-P∞)RwρcpTf(Le0.67))
Tw - Wet Bulb Temperature?T∞ - Air Temperature?hfg - Enthalpy of Evaporation?Pw - Partial Pressure?P∞ - Partial Pressure in air?Rw - Gas constant?ρ - Density?cp - Specific Heat of Air?Tf - Mean Temperature?Le - Lewis Number?

Wet bulb temperature given gas constant of water vapor Example

With values
With units
Only example

Here is how the Wet bulb temperature given gas constant of water vapor equation looks like with Values.

Here is how the Wet bulb temperature given gas constant of water vapor equation looks like with Units.

Here is how the Wet bulb temperature given gas constant of water vapor equation looks like.

34.9997Edit=35Edit-(90Edit(13Edit-0.016Edit)8.314Edit997Edit3Edit55Edit(4.5Edit0.67))
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Heat and Mass Transfer » fx Wet bulb temperature given gas constant of water vapor

Wet bulb temperature given gas constant of water vapor Solution

Follow our step by step solution on how to calculate Wet bulb temperature given gas constant of water vapor?

FIRST Step Consider the formula
Tw=T∞-(hfg(Pw-P∞)RwρcpTf(Le0.67))
Next Step Substitute values of Variables
Tw=35-(90J/kg*K(13-0.016)8.314997kg/m³3J/(kg*K)55(4.50.67))
Next Step Prepare to Evaluate
Tw=35-(90(13-0.016)8.314997355(4.50.67))
Next Step Evaluate
Tw=34.9996881042124
LAST Step Rounding Answer
Tw=34.9997

Wet bulb temperature given gas constant of water vapor Formula Elements

Variables
Wet Bulb Temperature
Wet Bulb Temperature is the temperature of the wet bulb and denoted by the symbol Tw.
Symbol: Tw
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Air Temperature
Air temperature is the temperature of the air surrounding an individual and is typically measured in degrees Celsius (°C) or in Kelvin.
Symbol: T∞
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Enthalpy of Evaporation
Enthalpy of evaporation is the amount of energy (enthalpy) that must be added to a liquid substance to transform a quantity of that substance into a gas.
Symbol: hfg
Measurement: Specific EntropyUnit: J/kg*K
Note: Value can be positive or negative.
Partial Pressure
Partial pressure of the water vapor at wet bulb temperature.
Symbol: Pw
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Partial Pressure in air
Partial pressure in air of the water vapor is the pressure of water in the mixture of water and air.
Symbol: P∞
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Gas constant
Gas constant is the value of gas constant of water vapour.
Symbol: Rw
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Density
The Density of a material shows the denseness of that material in a specific given area. This is taken as mass per unit volume of a given object.
Symbol: ρ
Measurement: DensityUnit: kg/m³
Note: Value should be greater than 0.
Specific Heat of Air
Specific heat of air is the heat required to raise the temperature of a air by one degree to that required to raise the temperature of an equal mass of water one degree.
Symbol: cp
Measurement: Specific Heat CapacityUnit: J/(kg*K)
Note: Value can be positive or negative.
Mean Temperature
Mean temperature is the mean value of all the observed temperatures.
Symbol: Tf
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Lewis Number
The Lewis Number is a dimensionless number defined as the ratio of thermal diffusivity to mass diffusivity.
Symbol: Le
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other Formulas to find Wet Bulb Temperature

​Go Wet bulb temperature of humidification
Tw=T∞-(0.622hfgcp(Le0.67))((PwPT)-(P∞PT))

Other formulas in Humidification category

​Go Enthalpy of evaporation for water in humidification
hfg=hConv(T∞-Tw)kL(Pw-P∞)
​Go Convective mass transfer coefficient in humidification
kL=hConv(T∞-Tw)hfg(Pw-P∞)

How to Evaluate Wet bulb temperature given gas constant of water vapor?

Wet bulb temperature given gas constant of water vapor evaluator uses Wet Bulb Temperature = Air Temperature-((Enthalpy of Evaporation*(Partial Pressure-Partial Pressure in air))/(Gas constant*Density*Specific Heat of Air*Mean Temperature*(Lewis Number^0.67))) to evaluate the Wet Bulb Temperature, The Wet bulb temperature given gas constant of water vapor formula is defined as the temperature of the parcel of air cooled to saturation. Wet Bulb Temperature is denoted by Tw symbol.

How to evaluate Wet bulb temperature given gas constant of water vapor using this online evaluator? To use this online evaluator for Wet bulb temperature given gas constant of water vapor, enter Air Temperature (T∞), Enthalpy of Evaporation (hfg), Partial Pressure (Pw), Partial Pressure in air (P∞), Gas constant (Rw), Density (ρ), Specific Heat of Air (cp), Mean Temperature (Tf) & Lewis Number (Le) and hit the calculate button.

FAQs on Wet bulb temperature given gas constant of water vapor

What is the formula to find Wet bulb temperature given gas constant of water vapor?
The formula of Wet bulb temperature given gas constant of water vapor is expressed as Wet Bulb Temperature = Air Temperature-((Enthalpy of Evaporation*(Partial Pressure-Partial Pressure in air))/(Gas constant*Density*Specific Heat of Air*Mean Temperature*(Lewis Number^0.67))). Here is an example- 34.99972 = 35-((90*(13-0.016))/(8.314*997*3*55*(4.5^0.67))).
How to calculate Wet bulb temperature given gas constant of water vapor?
With Air Temperature (T∞), Enthalpy of Evaporation (hfg), Partial Pressure (Pw), Partial Pressure in air (P∞), Gas constant (Rw), Density (ρ), Specific Heat of Air (cp), Mean Temperature (Tf) & Lewis Number (Le) we can find Wet bulb temperature given gas constant of water vapor using the formula - Wet Bulb Temperature = Air Temperature-((Enthalpy of Evaporation*(Partial Pressure-Partial Pressure in air))/(Gas constant*Density*Specific Heat of Air*Mean Temperature*(Lewis Number^0.67))).
What are the other ways to Calculate Wet Bulb Temperature?
Here are the different ways to Calculate Wet Bulb Temperature-
  • Wet Bulb Temperature=Air Temperature-((0.622*Enthalpy of Evaporation)/(Specific Heat of Air*(Lewis Number^0.67)))*((Partial Pressure/Total Pressure)-(Partial Pressure in air/Total Pressure))OpenImg
Copied!