Water Table Profile Neglecting Depths of Water in Drains Formula

Fx Copy
LaTeX Copy
The Water Table Profile refers to the depth of water table below aquifer. Check FAQs
h=(RK)(L-x)x
h - Water Table Profile?R - Natural Recharge?K - Coefficient of Permeability?L - Length between Tile Drain?x - Flow in 'x' Direction?

Water Table Profile Neglecting Depths of Water in Drains Example

With values
With units
Only example

Here is how the Water Table Profile Neglecting Depths of Water in Drains equation looks like with Values.

Here is how the Water Table Profile Neglecting Depths of Water in Drains equation looks like with Units.

Here is how the Water Table Profile Neglecting Depths of Water in Drains equation looks like.

3.7712Edit=(16Edit9Edit)(6Edit-2Edit)2Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Water Table Profile Neglecting Depths of Water in Drains

Water Table Profile Neglecting Depths of Water in Drains Solution

Follow our step by step solution on how to calculate Water Table Profile Neglecting Depths of Water in Drains?

FIRST Step Consider the formula
h=(RK)(L-x)x
Next Step Substitute values of Variables
h=(16m³/s9cm/s)(6m-2m³/s)2m³/s
Next Step Prepare to Evaluate
h=(169)(6-2)2
Next Step Evaluate
h=3.77123616632825m
LAST Step Rounding Answer
h=3.7712m

Water Table Profile Neglecting Depths of Water in Drains Formula Elements

Variables
Functions
Water Table Profile
The Water Table Profile refers to the depth of water table below aquifer.
Symbol: h
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Natural Recharge
The Natural Recharge is a process by which groundwater is replenished naturally when precipitation infiltrates the ground, moving through the soil and rock layers until it reaches the water table.
Symbol: R
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Coefficient of Permeability
The Coefficient of Permeability of soil describes how easily a liquid will move through the soil.
Symbol: K
Measurement: SpeedUnit: cm/s
Note: Value should be greater than 0.
Length between Tile Drain
The Length between Tile Drain refers to the approximate expression to the water table profile on a horizontal impervious boundary.
Symbol: L
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Flow in 'x' Direction
The Flow in 'x' Direction refers to the one-dimensional Dupit flow with recharge representation.
Symbol: x
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other formulas in Unconfined Flow by Dupit's Assumption category

​Go Mass Flux Entering Element
Mx1=ρwaterVxHwΔy
​Go Discharge per Unit Width of Aquifer considering Permeability
Q=(ho2-h12)K2Lstream
​Go Maximum Height of Water Table
hm=(L2)RK
​Go Length when Discharge entering per Unit Length of Drain is Considered
L=QR

How to Evaluate Water Table Profile Neglecting Depths of Water in Drains?

Water Table Profile Neglecting Depths of Water in Drains evaluator uses Water Table Profile = sqrt((Natural Recharge/Coefficient of Permeability)*(Length between Tile Drain-Flow in 'x' Direction)*Flow in 'x' Direction) to evaluate the Water Table Profile, The Water Table Profile Neglecting Depths of Water in Drains formula is defined as the upper surface of the zone of saturation, where the pores and fractures of the ground are saturated with water. Water Table Profile is denoted by h symbol.

How to evaluate Water Table Profile Neglecting Depths of Water in Drains using this online evaluator? To use this online evaluator for Water Table Profile Neglecting Depths of Water in Drains, enter Natural Recharge (R), Coefficient of Permeability (K), Length between Tile Drain (L) & Flow in 'x' Direction (x) and hit the calculate button.

FAQs on Water Table Profile Neglecting Depths of Water in Drains

What is the formula to find Water Table Profile Neglecting Depths of Water in Drains?
The formula of Water Table Profile Neglecting Depths of Water in Drains is expressed as Water Table Profile = sqrt((Natural Recharge/Coefficient of Permeability)*(Length between Tile Drain-Flow in 'x' Direction)*Flow in 'x' Direction). Here is an example- 3.771236 = sqrt((16/0.09)*(6-2)*2).
How to calculate Water Table Profile Neglecting Depths of Water in Drains?
With Natural Recharge (R), Coefficient of Permeability (K), Length between Tile Drain (L) & Flow in 'x' Direction (x) we can find Water Table Profile Neglecting Depths of Water in Drains using the formula - Water Table Profile = sqrt((Natural Recharge/Coefficient of Permeability)*(Length between Tile Drain-Flow in 'x' Direction)*Flow in 'x' Direction). This formula also uses Square Root (sqrt) function(s).
Can the Water Table Profile Neglecting Depths of Water in Drains be negative?
No, the Water Table Profile Neglecting Depths of Water in Drains, measured in Length cannot be negative.
Which unit is used to measure Water Table Profile Neglecting Depths of Water in Drains?
Water Table Profile Neglecting Depths of Water in Drains is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Water Table Profile Neglecting Depths of Water in Drains can be measured.
Copied!