Fx Copy
LaTeX Copy
Volumetric Flow Rate is the volume of fluid which passes per unit time. Check FAQs
Vf=2.635H52
Vf - Volumetric Flow Rate?H - Head of Water Above Sill of Notch?

Volumetric Flow Rate of Triangular Right Angled Notch Example

With values
With units
Only example

Here is how the Volumetric Flow Rate of Triangular Right Angled Notch equation looks like with Values.

Here is how the Volumetric Flow Rate of Triangular Right Angled Notch equation looks like with Units.

Here is how the Volumetric Flow Rate of Triangular Right Angled Notch equation looks like.

30.0008Edit=2.6352.6457Edit52
You are here -
HomeIcon Home » Category Engineering » Category Mechanical » Category Fluid Mechanics » fx Volumetric Flow Rate of Triangular Right Angled Notch

Volumetric Flow Rate of Triangular Right Angled Notch Solution

Follow our step by step solution on how to calculate Volumetric Flow Rate of Triangular Right Angled Notch?

FIRST Step Consider the formula
Vf=2.635H52
Next Step Substitute values of Variables
Vf=2.6352.6457m52
Next Step Prepare to Evaluate
Vf=2.6352.645752
Next Step Evaluate
Vf=30.0007500628196m³/s
LAST Step Rounding Answer
Vf=30.0008m³/s

Volumetric Flow Rate of Triangular Right Angled Notch Formula Elements

Variables
Volumetric Flow Rate
Volumetric Flow Rate is the volume of fluid which passes per unit time.
Symbol: Vf
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Head of Water Above Sill of Notch
Head of Water Above Sill of Notch is defined as the discharge over notch that is measured by measuring the head acting over the notch.
Symbol: H
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other Formulas to find Volumetric Flow Rate

​Go Volumetric Flow Rate at Vena Contracta
Vf=CdAvc2[g]Hw
​Go Volumetric Flow Rate of Circular Orifice
Vf=0.62a2[g]Hw
​Go Volumetric Flow Rate of Rectangular Notch
Vf=0.62bH232[g]Hw
​Go Volumetric Flow Rate of Venacontracta given Contraction and Velocity
Vf=CcCvAvc2[g]Hw

Other formulas in Flow Rate category

​Go Rate of Flow
Qf=AVavg
​Go Rate of Flow given Head loss in Laminar Flow
Qf=hlγfπdp4128μLp
​Go Rate of Flow given Hydraulic Transmission Power
Qf=Pγl(He-hl)

How to Evaluate Volumetric Flow Rate of Triangular Right Angled Notch?

Volumetric Flow Rate of Triangular Right Angled Notch evaluator uses Volumetric Flow Rate = 2.635*Head of Water Above Sill of Notch^(5/2) to evaluate the Volumetric Flow Rate, The Volumetric flow rate of triangular right angled notch formula is defined as a measure of the 3-dimensional space that the gas or liquid occupies as it flows through the instrument under the measured pressure and temperature conditions. Volumetric Flow Rate is denoted by Vf symbol.

How to evaluate Volumetric Flow Rate of Triangular Right Angled Notch using this online evaluator? To use this online evaluator for Volumetric Flow Rate of Triangular Right Angled Notch, enter Head of Water Above Sill of Notch (H) and hit the calculate button.

FAQs on Volumetric Flow Rate of Triangular Right Angled Notch

What is the formula to find Volumetric Flow Rate of Triangular Right Angled Notch?
The formula of Volumetric Flow Rate of Triangular Right Angled Notch is expressed as Volumetric Flow Rate = 2.635*Head of Water Above Sill of Notch^(5/2). Here is an example- 30.00075 = 2.635*2.6457^(5/2).
How to calculate Volumetric Flow Rate of Triangular Right Angled Notch?
With Head of Water Above Sill of Notch (H) we can find Volumetric Flow Rate of Triangular Right Angled Notch using the formula - Volumetric Flow Rate = 2.635*Head of Water Above Sill of Notch^(5/2).
What are the other ways to Calculate Volumetric Flow Rate?
Here are the different ways to Calculate Volumetric Flow Rate-
  • Volumetric Flow Rate=Coefficient of Discharge*Area of Jet at Vena Contracta*sqrt(2*[g]*Head)OpenImg
  • Volumetric Flow Rate=0.62*Area of Orifice*sqrt(2*[g]*Head)OpenImg
  • Volumetric Flow Rate=0.62*Thickness of Dam*Head of Water Above Sill of Notch*2/3*sqrt(2*[g]*Head)OpenImg
Can the Volumetric Flow Rate of Triangular Right Angled Notch be negative?
No, the Volumetric Flow Rate of Triangular Right Angled Notch, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Volumetric Flow Rate of Triangular Right Angled Notch?
Volumetric Flow Rate of Triangular Right Angled Notch is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Volumetric Flow Rate of Triangular Right Angled Notch can be measured.
Copied!