Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester Formula

Fx Copy
LaTeX Copy
Volumetric Flow Rate is referred as measure of the volume of fluid that flows through a given surface per unit time. Check FAQs
V=(BODdayVl)
V - Volumetric Flow Rate?BODday - BOD per Day?Vl - Volumetric Loading?

Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester Example

With values
With units
Only example

Here is how the Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester equation looks like with Values.

Here is how the Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester equation looks like with Units.

Here is how the Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester equation looks like.

4.8225Edit=(10Edit2.4E-5Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester

Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester Solution

Follow our step by step solution on how to calculate Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester?

FIRST Step Consider the formula
V=(BODdayVl)
Next Step Substitute values of Variables
V=(10kg/d2.4E-5kg/m³)
Next Step Convert Units
V=(0.0001kg/s2.4E-5kg/m³)
Next Step Prepare to Evaluate
V=(0.00012.4E-5)
Next Step Evaluate
V=4.82253086419754m³/s
LAST Step Rounding Answer
V=4.8225m³/s

Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester Formula Elements

Variables
Volumetric Flow Rate
Volumetric Flow Rate is referred as measure of the volume of fluid that flows through a given surface per unit time.
Symbol: V
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
BOD per Day
BOD per Day is defined as biological oxygen demand in terms of mass flow rate.
Symbol: BODday
Measurement: Mass Flow RateUnit: kg/d
Note: Value should be greater than 0.
Volumetric Loading
Volumetric Loading is referred as the amount of wastewater or sludge applied to a treatment unit per unit volume of the unit per unit time.
Symbol: Vl
Measurement: DensityUnit: kg/m³
Note: Value should be greater than 0.

Other formulas in Design of an Anaerobic Digester category

​Go Volume Required for Anaerobic Digester
VT=(θQs)
​Go Hydraulic Retention Time given Volume Required for Anaerobic Digester
θh=(VTQs)
​Go Influent Sludge Flow Rate given Volume Required for Anaerobic Digester
Qs=(VTθ)
​Go Volumetric Loading in Anaerobic Digester
Vl=(BODdayV)

How to Evaluate Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester?

Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester evaluator uses Volumetric Flow Rate = (BOD per Day/Volumetric Loading) to evaluate the Volumetric Flow Rate, The Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester formula is defined as the the volume of liquid (feedstock) entering the digester per unit time. It is typically measured in cubic meters per day (m³/day). Volumetric Flow Rate is denoted by V symbol.

How to evaluate Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester using this online evaluator? To use this online evaluator for Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester, enter BOD per Day (BODday) & Volumetric Loading (Vl) and hit the calculate button.

FAQs on Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester

What is the formula to find Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester?
The formula of Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester is expressed as Volumetric Flow Rate = (BOD per Day/Volumetric Loading). Here is an example- 4.822531 = (0.000115740740740741/2.4E-05).
How to calculate Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester?
With BOD per Day (BODday) & Volumetric Loading (Vl) we can find Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester using the formula - Volumetric Flow Rate = (BOD per Day/Volumetric Loading).
Can the Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester be negative?
No, the Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester?
Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Volumetric Flow Rate given Volumetric Loading in Anaerobic Digester can be measured.