Volumetric Efficiency is the ratio of the volume of air/charge drawn into the cylinder(s) during the suction stroke to the total displacement of all the cylinder(s) at the atmospheric pressure. Check FAQs
ηv=VaVp
ηv - Volumetric Efficiency?Va - Actual Volume?Vp - Piston Swept Volume?

Volumetric Efficiency of Reciprocating Compressor Example

With values
With units
Only example

Here is how the Volumetric Efficiency of Reciprocating Compressor equation looks like with Values.

Here is how the Volumetric Efficiency of Reciprocating Compressor equation looks like with Units.

Here is how the Volumetric Efficiency of Reciprocating Compressor equation looks like.

0.8Edit=164Edit205Edit
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Design of Machine Elements » fx Volumetric Efficiency of Reciprocating Compressor

Volumetric Efficiency of Reciprocating Compressor Solution

Follow our step by step solution on how to calculate Volumetric Efficiency of Reciprocating Compressor?

FIRST Step Consider the formula
ηv=VaVp
Next Step Substitute values of Variables
ηv=164205
Next Step Prepare to Evaluate
ηv=164205
LAST Step Evaluate
ηv=0.8

Volumetric Efficiency of Reciprocating Compressor Formula Elements

Variables
Volumetric Efficiency
Volumetric Efficiency is the ratio of the volume of air/charge drawn into the cylinder(s) during the suction stroke to the total displacement of all the cylinder(s) at the atmospheric pressure.
Symbol: ηv
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Actual Volume
Actual Volume means, in any given hour, the total amount of real power that is being consumed or is being consumed as an aggregated volume by the Service Provider that is subject to LSSi.
Symbol: Va
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Piston Swept Volume
Piston Swept Volume is defined as the displacement of one cylinder. It is the volume between top dead center (TDC) and bottom dead center (BDC).
Symbol: Vp
Measurement: VolumeUnit:
Note: Value should be greater than 0.

Other formulas in Leakage through Bush Seals category

​Go Oil Flow through Plain Axial Bush Seal due to Leakage under Laminar Flow Condition
Q=2πa(Ps-Pe106)lq
​Go Oil Flow through Plain Radial Bush Seal due to Leakage under Laminar Flow Condition
Q=2πa(Ps-Pe106)a-bq
​Go Volumetric Flow Rate under Laminar Flow Condition for Axial Bush Seal for Compressible Fluid
q=c312μPs+PePe
​Go Volumetric Flow Rate under Laminar Flow Condition for Radial Bush Seal for Incompressible Fluid
q=c312μa-baln(ab)

How to Evaluate Volumetric Efficiency of Reciprocating Compressor?

Volumetric Efficiency of Reciprocating Compressor evaluator uses Volumetric Efficiency = Actual Volume/Piston Swept Volume to evaluate the Volumetric Efficiency, The Volumetric Efficiency of Reciprocating Compressor represents the efficiency of a compressor cylinder to compress gas. It may be defined as the ratio of the volume of gas actually delivered to the piston displacement, corrected to suction temperature and pressure. The principal reasons that the cylinder will not deliver the piston displacement capacity are wire-drawing, a throttling effect on the valves; heating of the gas during admission to the cylinder; leakage past valves and piston rings; and re-expansion of the gas trapped in the clearance-volume space from the previous stroke. Re-expansion has by far the greatest effect on volumetric efficiency. Volumetric Efficiency is denoted by ηv symbol.

How to evaluate Volumetric Efficiency of Reciprocating Compressor using this online evaluator? To use this online evaluator for Volumetric Efficiency of Reciprocating Compressor, enter Actual Volume (Va) & Piston Swept Volume (Vp) and hit the calculate button.

FAQs on Volumetric Efficiency of Reciprocating Compressor

What is the formula to find Volumetric Efficiency of Reciprocating Compressor?
The formula of Volumetric Efficiency of Reciprocating Compressor is expressed as Volumetric Efficiency = Actual Volume/Piston Swept Volume. Here is an example- 0.8 = 164/205.
How to calculate Volumetric Efficiency of Reciprocating Compressor?
With Actual Volume (Va) & Piston Swept Volume (Vp) we can find Volumetric Efficiency of Reciprocating Compressor using the formula - Volumetric Efficiency = Actual Volume/Piston Swept Volume.
Copied!