Fx Copy
LaTeX Copy
Organic Loading is the amount of organic matter, typically measured as biochemical oxygen demand or chemical oxygen demand, that is introduced into a wastewater treatment system. Check FAQs
VL=Bod_massV
VL - Organic Loading?Bod_mass - Mass of BOD?V - Volume of Tank?

Volumetric BOD Loading or Organic Loading Example

With values
With units
Only example

Here is how the Volumetric BOD Loading or Organic Loading equation looks like with Values.

Here is how the Volumetric BOD Loading or Organic Loading equation looks like with Units.

Here is how the Volumetric BOD Loading or Organic Loading equation looks like.

1.2314Edit=11.07Edit8.99Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Volumetric BOD Loading or Organic Loading

Volumetric BOD Loading or Organic Loading Solution

Follow our step by step solution on how to calculate Volumetric BOD Loading or Organic Loading?

FIRST Step Consider the formula
VL=Bod_massV
Next Step Substitute values of Variables
VL=11.07g8.99
Next Step Convert Units
VL=0.0111kg8.99
Next Step Prepare to Evaluate
VL=0.01118.99
Next Step Evaluate
VL=0.0012313681868743kg/m³
Next Step Convert to Output's Unit
VL=1.2313681868743mg/L
LAST Step Rounding Answer
VL=1.2314mg/L

Volumetric BOD Loading or Organic Loading Formula Elements

Variables
Organic Loading
Organic Loading is the amount of organic matter, typically measured as biochemical oxygen demand or chemical oxygen demand, that is introduced into a wastewater treatment system.
Symbol: VL
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Mass of BOD
Mass of BOD is the total amount of oxygen required by microorganisms to decompose the organic matter present in a given volume of water over a specific period.
Symbol: Bod_mass
Measurement: WeightUnit: g
Note: Value should be greater than 0.
Volume of Tank
Volume of Tank is defined as the capacity of flocculation and mixing tank.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.

Other Formulas to find Organic Loading

​Go Organic Loading given BOD of influent Sewage
VL=QBODiV

Other formulas in Volumetric BOD Loading category

​Go Mass of BOD Applied Per Day given Organic Loading
Bod_mass=VVL
​Go Sewage Flow into Aeration Tank given Organic Loading
Q=VVLBODi
​Go Volume of Aeration Tank given Organic Loading
V=QBODiVL
​Go BOD of Influent Sewage given Organic Loading
BODi=VVLQ

How to Evaluate Volumetric BOD Loading or Organic Loading?

Volumetric BOD Loading or Organic Loading evaluator uses Organic Loading = Mass of BOD/Volume of Tank to evaluate the Organic Loading, The Volumetric BOD Loading or Organic Loading formula is defined as the calculation of volumetric BOD loading, also known as organic loading, which is a key parameter used in wastewater treatment, particularly in the design and operation of biological treatment processes such as activated sludge systems, trickling filters, and anaerobic digesters. Organic Loading is denoted by VL symbol.

How to evaluate Volumetric BOD Loading or Organic Loading using this online evaluator? To use this online evaluator for Volumetric BOD Loading or Organic Loading, enter Mass of BOD (Bod_mass) & Volume of Tank (V) and hit the calculate button.

FAQs on Volumetric BOD Loading or Organic Loading

What is the formula to find Volumetric BOD Loading or Organic Loading?
The formula of Volumetric BOD Loading or Organic Loading is expressed as Organic Loading = Mass of BOD/Volume of Tank. Here is an example- 1230 = 0.01107/8.99.
How to calculate Volumetric BOD Loading or Organic Loading?
With Mass of BOD (Bod_mass) & Volume of Tank (V) we can find Volumetric BOD Loading or Organic Loading using the formula - Organic Loading = Mass of BOD/Volume of Tank.
What are the other ways to Calculate Organic Loading?
Here are the different ways to Calculate Organic Loading-
  • Organic Loading=(Sewage Flow*BOD Influent)/Volume of TankOpenImg
Can the Volumetric BOD Loading or Organic Loading be negative?
No, the Volumetric BOD Loading or Organic Loading, measured in Density cannot be negative.
Which unit is used to measure Volumetric BOD Loading or Organic Loading?
Volumetric BOD Loading or Organic Loading is usually measured using the Milligram per Liter[mg/L] for Density. Kilogram per Cubic Meter[mg/L], Kilogram per Cubic Centimeter[mg/L], Gram per Cubic Meter[mg/L] are the few other units in which Volumetric BOD Loading or Organic Loading can be measured.
Copied!