Volume of Wasted Sludge Per Day Formula

Fx Copy
LaTeX Copy
Volume of Wasted Sludge per day is the amount of sludge that is removed from a wastewater treatment process within a 24-hour period. Check FAQs
Qw=MsXR
Qw - Volume of Wasted Sludge per day?Ms - Mass of Solids?XR - Concentration of Solids in Returned Sludge?

Volume of Wasted Sludge Per Day Example

With values
With units
Only example

Here is how the Volume of Wasted Sludge Per Day equation looks like with Values.

Here is how the Volume of Wasted Sludge Per Day equation looks like with Units.

Here is how the Volume of Wasted Sludge Per Day equation looks like.

9.5057Edit=5000Edit0.526Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Volume of Wasted Sludge Per Day

Volume of Wasted Sludge Per Day Solution

Follow our step by step solution on how to calculate Volume of Wasted Sludge Per Day?

FIRST Step Consider the formula
Qw=MsXR
Next Step Substitute values of Variables
Qw=5000mg0.526mg/L
Next Step Convert Units
Qw=0.005kg0.0005kg/m³
Next Step Prepare to Evaluate
Qw=0.0050.0005
Next Step Evaluate
Qw=9.50570342205323m³/s
LAST Step Rounding Answer
Qw=9.5057m³/s

Volume of Wasted Sludge Per Day Formula Elements

Variables
Volume of Wasted Sludge per day
Volume of Wasted Sludge per day is the amount of sludge that is removed from a wastewater treatment process within a 24-hour period.
Symbol: Qw
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Mass of Solids
Mass of Solids means the actual weight of the solid particle present in the sewage.
Symbol: Ms
Measurement: WeightUnit: mg
Note: Value should be greater than 0.
Concentration of Solids in Returned Sludge
Concentration of Solids in Returned Sludge is the density of solid particles present in the sludge that is returned from the secondary settling tanks to the aeration tank.
Symbol: XR
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.

Other formulas in Volume of Wasted Sludge category

​Go Mass of Wasted Activated Sludge
Mws=(YQs(Qi-Qo))-(KeVX')
​Go Concentration of Solids in Returned Sludge given MLSS
XEm=X'VQwθc
​Go Endogenous Respiration Rate Constant given Mass of Wasted Activated Sludge
Ke=(YQs(Qi-Qo))-MwsX'V
​Go Endogenous Respiration Rate Constant given Maximum Yield Coefficient
Ke=(YU)-(1θc)

How to Evaluate Volume of Wasted Sludge Per Day?

Volume of Wasted Sludge Per Day evaluator uses Volume of Wasted Sludge per day = Mass of Solids/Concentration of Solids in Returned Sludge to evaluate the Volume of Wasted Sludge per day, The Volume of Wasted Sludge Per Day formula is defined as the calculation of volume of wasted sludge per day when we have prior information of other parameters used. Volume of Wasted Sludge per day is denoted by Qw symbol.

How to evaluate Volume of Wasted Sludge Per Day using this online evaluator? To use this online evaluator for Volume of Wasted Sludge Per Day, enter Mass of Solids (Ms) & Concentration of Solids in Returned Sludge (XR) and hit the calculate button.

FAQs on Volume of Wasted Sludge Per Day

What is the formula to find Volume of Wasted Sludge Per Day?
The formula of Volume of Wasted Sludge Per Day is expressed as Volume of Wasted Sludge per day = Mass of Solids/Concentration of Solids in Returned Sludge. Here is an example- 2.5 = 0.005/concentration_solid_sludge_age.
How to calculate Volume of Wasted Sludge Per Day?
With Mass of Solids (Ms) & Concentration of Solids in Returned Sludge (XR) we can find Volume of Wasted Sludge Per Day using the formula - Volume of Wasted Sludge per day = Mass of Solids/Concentration of Solids in Returned Sludge.
Can the Volume of Wasted Sludge Per Day be negative?
No, the Volume of Wasted Sludge Per Day, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Volume of Wasted Sludge Per Day?
Volume of Wasted Sludge Per Day is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Volume of Wasted Sludge Per Day can be measured.
Copied!