Fx Copy
LaTeX Copy
Volume of Tank is defined as the capacity of flocculation and mixing tank. Check FAQs
V=QQiFMX
V - Volume of Tank?Q - Sewage Flow?Qi - Influent BOD?FM - Food to Microorganism Ratio?X - MLSS?

Volume of Tank given Food to Microorganism Ratio Example

With values
With units
Only example

Here is how the Volume of Tank given Food to Microorganism Ratio equation looks like with Values.

Here is how the Volume of Tank given Food to Microorganism Ratio equation looks like with Units.

Here is how the Volume of Tank given Food to Microorganism Ratio equation looks like.

1.4985Edit=3.33Edit0.0009Edit0.001Edit2Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Volume of Tank given Food to Microorganism Ratio

Volume of Tank given Food to Microorganism Ratio Solution

Follow our step by step solution on how to calculate Volume of Tank given Food to Microorganism Ratio?

FIRST Step Consider the formula
V=QQiFMX
Next Step Substitute values of Variables
V=3.330.0009mg/L0.0012mg/L
Next Step Convert Units
V=3.339E-7kg/m³0.0010.002kg/m³
Next Step Prepare to Evaluate
V=3.339E-70.0010.002
LAST Step Evaluate
V=1.4985

Volume of Tank given Food to Microorganism Ratio Formula Elements

Variables
Volume of Tank
Volume of Tank is defined as the capacity of flocculation and mixing tank.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Sewage Flow
Sewage Flow into the aeration tank is the sewage flow into the aeration tank when we have prior information of other parameters used.
Symbol: Q
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Influent BOD
Influent BOD is the total amount of BOD which is present in the incoming sewage.
Symbol: Qi
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Food to Microorganism Ratio
Food to Microorganism Ratio is actually a measurement of the amount of incoming food divided by the Lbs of Microorganisms in your system.
Symbol: FM
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
MLSS
MLSS is the concentration of suspended solids in the mixed liquor within an aeration tank during the activated sludge process.
Symbol: X
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.

Other Formulas to find Volume of Tank

​Go Volume of Tank given Microbial Mass in Aeration System
V=MtX
​Go Volume of Tank given MLSS
V=MtQQiXBOD

Other formulas in Food is to Microorganism Ratio or F is to M Ratio category

​Go Food to Microorganism Ratio
FM=BODMt
​Go Daily BOD Load given Food to Microorganism Ratio
BOD=FMMt
​Go Total Microbial Mass given Food to Microorganism Ratio
Mt=BODFM
​Go BOD Load applied to Aeration System
BODa=QQi

How to Evaluate Volume of Tank given Food to Microorganism Ratio?

Volume of Tank given Food to Microorganism Ratio evaluator uses Volume of Tank = (Sewage Flow*Influent BOD)/(Food to Microorganism Ratio*MLSS) to evaluate the Volume of Tank, The Volume of Tank given Food to Microorganism Ratio formula is defined as the calculation of the volume of a biological treatment tank, such as an aeration tank in a wastewater treatment plant, based on the ratio of the organic load (food) to the concentration of microorganisms (biomass) present in the system. Volume of Tank is denoted by V symbol.

How to evaluate Volume of Tank given Food to Microorganism Ratio using this online evaluator? To use this online evaluator for Volume of Tank given Food to Microorganism Ratio, enter Sewage Flow (Q), Influent BOD (Qi), Food to Microorganism Ratio (FM) & MLSS (X) and hit the calculate button.

FAQs on Volume of Tank given Food to Microorganism Ratio

What is the formula to find Volume of Tank given Food to Microorganism Ratio?
The formula of Volume of Tank given Food to Microorganism Ratio is expressed as Volume of Tank = (Sewage Flow*Influent BOD)/(Food to Microorganism Ratio*MLSS). Here is an example- 1.4985 = (3.33*9E-07)/(0.001*0.002).
How to calculate Volume of Tank given Food to Microorganism Ratio?
With Sewage Flow (Q), Influent BOD (Qi), Food to Microorganism Ratio (FM) & MLSS (X) we can find Volume of Tank given Food to Microorganism Ratio using the formula - Volume of Tank = (Sewage Flow*Influent BOD)/(Food to Microorganism Ratio*MLSS).
What are the other ways to Calculate Volume of Tank?
Here are the different ways to Calculate Volume of Tank-
  • Volume of Tank=Total Microbial Mass/MLSSOpenImg
  • Volume of Tank=(Total Microbial Mass*Sewage Flow*Influent BOD)/(MLSS*Daily BOD)OpenImg
Can the Volume of Tank given Food to Microorganism Ratio be negative?
No, the Volume of Tank given Food to Microorganism Ratio, measured in Volume cannot be negative.
Which unit is used to measure Volume of Tank given Food to Microorganism Ratio?
Volume of Tank given Food to Microorganism Ratio is usually measured using the Cubic Meter[m³] for Volume. Cubic Centimeter[m³], Cubic Millimeter[m³], Liter[m³] are the few other units in which Volume of Tank given Food to Microorganism Ratio can be measured.
Copied!