Fx Copy
LaTeX Copy
The Volume of Stationary Phase is the amount of motionless part of the chromatography column. Check FAQs
Vs=Vmobile phaseCmk'Cs
Vs - Volume of Stationary Phase?Vmobile phase - Volume of Mobile Phase?Cm - Concentration of Mobile Phase?k' - Capacity Factor?Cs - Concentration of Stationary Phase?

Volume of Stationary Phase given Capacity Factor Example

With values
With units
Only example

Here is how the Volume of Stationary Phase given Capacity Factor equation looks like with Values.

Here is how the Volume of Stationary Phase given Capacity Factor equation looks like with Units.

Here is how the Volume of Stationary Phase given Capacity Factor equation looks like.

9Edit=5Edit6Edit3Edit10Edit
You are here -
HomeIcon Home » Category Chemistry » Category Analytical chemistry » Category Method of Separation Technique » fx Volume of Stationary Phase given Capacity Factor

Volume of Stationary Phase given Capacity Factor Solution

Follow our step by step solution on how to calculate Volume of Stationary Phase given Capacity Factor?

FIRST Step Consider the formula
Vs=Vmobile phaseCmk'Cs
Next Step Substitute values of Variables
Vs=5L6mol/L310mol/L
Next Step Convert Units
Vs=0.0056000mol/m³310000mol/m³
Next Step Prepare to Evaluate
Vs=0.0056000310000
Next Step Evaluate
Vs=0.009
LAST Step Convert to Output's Unit
Vs=9L

Volume of Stationary Phase given Capacity Factor Formula Elements

Variables
Volume of Stationary Phase
The Volume of Stationary Phase is the amount of motionless part of the chromatography column.
Symbol: Vs
Measurement: VolumeUnit: L
Note: Value can be positive or negative.
Volume of Mobile Phase
The Volume of Mobile Phase is the amount of the solvent that runs through the chromatography column.
Symbol: Vmobile phase
Measurement: VolumeUnit: L
Note: Value can be positive or negative.
Concentration of Mobile Phase
The Concentration of Mobile Phase is the application of a solution that runs through the column.
Symbol: Cm
Measurement: Molar ConcentrationUnit: mol/L
Note: Value can be positive or negative.
Capacity Factor
The Capacity factor is directly proportional to the retention factor. The longer a component is retained by the column, the greater is the capacity factor.
Symbol: k'
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Concentration of Stationary Phase
The Concentration of stationary phase is the application of the motionless part of the chromatography column.
Symbol: Cs
Measurement: Molar ConcentrationUnit: mol/L
Note: Value can be positive or negative.

Other Formulas to find Volume of Stationary Phase

​Go Volume of Stationary Phase given Capacity Factor and Partition Coefficient
Vs=k'Vmobile phaseK

Other formulas in Volume and Concentration of Mobile and Stationary Phase category

​Go Volume of Mobile Phase given Capacity Factor
Vmobile phase=VsCsk'Cm
​Go Volume of Mobile Phase given Capacity Factor and Partition Coefficient
Vmobile phase=K(Vsk')
​Go Concentration of Mobile Phase given Capacity Factor
Cm=VsCsVmobile phasek'
​Go Concentration of Stationary Phase given Capacity Factor
Cs=CmVmobile phasek'Vs

How to Evaluate Volume of Stationary Phase given Capacity Factor?

Volume of Stationary Phase given Capacity Factor evaluator uses Volume of Stationary Phase = (Volume of Mobile Phase*Concentration of Mobile Phase*Capacity Factor)/Concentration of Stationary Phase to evaluate the Volume of Stationary Phase, The Volume of stationary phase given capacity factor formula is defined as the ratio of concentration and volume of mobile phase and capacity factor to the concentration of the stationary phase. Volume of Stationary Phase is denoted by Vs symbol.

How to evaluate Volume of Stationary Phase given Capacity Factor using this online evaluator? To use this online evaluator for Volume of Stationary Phase given Capacity Factor, enter Volume of Mobile Phase (Vmobile phase), Concentration of Mobile Phase (Cm), Capacity Factor (k') & Concentration of Stationary Phase (Cs) and hit the calculate button.

FAQs on Volume of Stationary Phase given Capacity Factor

What is the formula to find Volume of Stationary Phase given Capacity Factor?
The formula of Volume of Stationary Phase given Capacity Factor is expressed as Volume of Stationary Phase = (Volume of Mobile Phase*Concentration of Mobile Phase*Capacity Factor)/Concentration of Stationary Phase. Here is an example- 9000 = (0.005*6000*3)/10000.
How to calculate Volume of Stationary Phase given Capacity Factor?
With Volume of Mobile Phase (Vmobile phase), Concentration of Mobile Phase (Cm), Capacity Factor (k') & Concentration of Stationary Phase (Cs) we can find Volume of Stationary Phase given Capacity Factor using the formula - Volume of Stationary Phase = (Volume of Mobile Phase*Concentration of Mobile Phase*Capacity Factor)/Concentration of Stationary Phase.
What are the other ways to Calculate Volume of Stationary Phase?
Here are the different ways to Calculate Volume of Stationary Phase-
  • Volume of Stationary Phase=(Capacity Factor*Volume of Mobile Phase)/Partition CoefficientOpenImg
Can the Volume of Stationary Phase given Capacity Factor be negative?
Yes, the Volume of Stationary Phase given Capacity Factor, measured in Volume can be negative.
Which unit is used to measure Volume of Stationary Phase given Capacity Factor?
Volume of Stationary Phase given Capacity Factor is usually measured using the Liter[L] for Volume. Cubic Meter[L], Cubic Centimeter[L], Cubic Millimeter[L] are the few other units in which Volume of Stationary Phase given Capacity Factor can be measured.
Copied!