Fx Copy
LaTeX Copy
Reactor Volume refers to the physical volume of a reactor used in chemical processes. Check FAQs
V=θcQw'XrX
V - Reactor Volume?θc - Mean Cell Residence Time?Qw' - WAS Pumping Rate from Return Line?Xr - Sludge Concentration in Return Line?X - MLSS?

Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low Example

With values
With units
Only example

Here is how the Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low equation looks like with Values.

Here is how the Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low equation looks like with Units.

Here is how the Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low equation looks like.

466.6667Edit=7Edit400Edit200Edit1200Edit
You are here -

Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low Solution

Follow our step by step solution on how to calculate Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low?

FIRST Step Consider the formula
V=θcQw'XrX
Next Step Substitute values of Variables
V=7d400m³/d200mg/L1200mg/L
Next Step Convert Units
V=604800s0.0046m³/s0.2kg/m³1.2kg/m³
Next Step Prepare to Evaluate
V=6048000.00460.21.2
Next Step Evaluate
V=466.666666666667
LAST Step Rounding Answer
V=466.6667

Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low Formula Elements

Variables
Reactor Volume
Reactor Volume refers to the physical volume of a reactor used in chemical processes.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Mean Cell Residence Time
Mean Cell Residence Time is the average time that the sludge remains in the reactor.
Symbol: θc
Measurement: TimeUnit: d
Note: Value should be between 5 to 15.
WAS Pumping Rate from Return Line
WAS Pumping Rate from Return Line is the flow rate of waste sludge from the return line.
Symbol: Qw'
Measurement: Volumetric Flow RateUnit: m³/d
Note: Value should be greater than 0.
Sludge Concentration in Return Line
Sludge Concentration in Return Line refers to the concentration of suspended solids in the sludge that is being pumped back from the secondary clarifier to the aeration tank.
Symbol: Xr
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
MLSS
MLSS is the sum of volatile suspended solids (organics) and fixed suspended solids (inorganics).
Symbol: X
Measurement: DensityUnit: mg/L
Note: Value should be between 1000 to 6500.

Other Formulas to find Reactor Volume

​Go Volume of Reactor
V=θcYQa(So-S)Xa(1+(θckd))
​Go Volume of Reactor given Hydraulic Retention Time
V=θQa
​Go Volume of Reactor given Wasting Rate from Return Line
V=θc(Qw'Xr)+(QeXe)X
​Go Volume of Reactor given WAS Pumping Rate from Aeration Tank
V=θcQw

How to Evaluate Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low?

Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low evaluator uses Reactor Volume = Mean Cell Residence Time*WAS Pumping Rate from Return Line*Sludge Concentration in Return Line/MLSS to evaluate the Reactor Volume, The Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low formula is defined as the capacity of the reactor to treat wastewater and maintain the desired hydraulic retention time (HRT) and solids retention time (SRT). Reactor Volume is denoted by V symbol.

How to evaluate Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low using this online evaluator? To use this online evaluator for Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low, enter Mean Cell Residence Time c), WAS Pumping Rate from Return Line (Qw'), Sludge Concentration in Return Line (Xr) & MLSS (X) and hit the calculate button.

FAQs on Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low

What is the formula to find Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low?
The formula of Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low is expressed as Reactor Volume = Mean Cell Residence Time*WAS Pumping Rate from Return Line*Sludge Concentration in Return Line/MLSS. Here is an example- 466.6667 = 604800*0.00462962962962963*0.2/1.2.
How to calculate Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low?
With Mean Cell Residence Time c), WAS Pumping Rate from Return Line (Qw'), Sludge Concentration in Return Line (Xr) & MLSS (X) we can find Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low using the formula - Reactor Volume = Mean Cell Residence Time*WAS Pumping Rate from Return Line*Sludge Concentration in Return Line/MLSS.
What are the other ways to Calculate Reactor Volume?
Here are the different ways to Calculate Reactor Volume-
  • Reactor Volume=(Mean Cell Residence Time*Maximum Yield Coefficient*Average Daily Influent Flow Rate*(Influent Substrate Concentration-Effluent Substrate Concentration))/(MLVSS*(1+(Mean Cell Residence Time*Endogenous Decay Coefficient)))OpenImg
  • Reactor Volume=Hydraulic Retention Time*Average Daily Influent Flow RateOpenImg
  • Reactor Volume=Mean Cell Residence Time*((WAS Pumping Rate from Return Line*Sludge Concentration in Return Line)+(Effluent Flow Rate*Solid Concentration in Effluent))/MLSSOpenImg
Can the Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low be negative?
No, the Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low, measured in Volume cannot be negative.
Which unit is used to measure Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low?
Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low is usually measured using the Cubic Meter[m³] for Volume. Cubic Centimeter[m³], Cubic Millimeter[m³], Liter[m³] are the few other units in which Volume of Reactor using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low can be measured.
Copied!