Volume of Tank refers to the total capacity or size of a tank used for storing liquids, such as water, chemicals, or wastewater. Check FAQs
V=(P(G)2μviscosity)
V - Volume of Tank?P - Power Requirement?G - Mean Velocity Gradient?μviscosity - Dynamic Viscosity?

Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations Example

With values
With units
Only example

Here is how the Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations equation looks like with Values.

Here is how the Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations equation looks like with Units.

Here is how the Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations equation looks like.

9Edit=(3Edit(2Edit)2833.33Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations

Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations Solution

Follow our step by step solution on how to calculate Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations?

FIRST Step Consider the formula
V=(P(G)2μviscosity)
Next Step Substitute values of Variables
V=(3kJ/s(2s⁻¹)2833.33P)
Next Step Convert Units
V=(3000W(2s⁻¹)283.333Pa*s)
Next Step Prepare to Evaluate
V=(3000(2)283.333)
Next Step Evaluate
V=9.000036000144
LAST Step Rounding Answer
V=9

Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations Formula Elements

Variables
Volume of Tank
Volume of Tank refers to the total capacity or size of a tank used for storing liquids, such as water, chemicals, or wastewater.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Power Requirement
Power Requirement refers to the amount of energy needed to operate various processes, systems, or equipment involved in environmental management.
Symbol: P
Measurement: PowerUnit: kJ/s
Note: Value should be greater than 0.
Mean Velocity Gradient
Mean Velocity Gradient refers to the rate of change of velocity within a fluid over a specified distance or depth.
Symbol: G
Measurement: First Order Reaction Rate ConstantUnit: s⁻¹
Note: Value should be greater than 0.
Dynamic Viscosity
Dynamic Viscosity refers to a measure of a fluid's resistance to flow under an applied force or shear stress.
Symbol: μviscosity
Measurement: Dynamic ViscosityUnit: P
Note: Value should be greater than 0.

Other Formulas to find Volume of Tank

​Go Volume of Mixing Tank given Mean Velocity Gradient
V=(P(G)2μviscosity)
​Go Required Volume of Flocculation Basin
V=TQeTm/d
​Go Volume of Flocculation Basin given Power Requirement for Flocculation
V=(P(G)2μviscosity)

Other formulas in Design of Rapid Mix Basin and Flocculation Basin category

​Go Volume of Rapid Mix Basin
Vrapid=θW
​Go Hydraulic Retention Time given Volume of Rapid Mix Basin
θs=VrapidQFr'
​Go Wastewater Flow given Volume of Rapid Mix Basin
W=Vrapidθ
​Go Mean Velocity Gradient given Power Requirement
G=PμviscosityV

How to Evaluate Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations?

Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations evaluator uses Volume of Tank = (Power Requirement/((Mean Velocity Gradient)^2*Dynamic Viscosity)) to evaluate the Volume of Tank, The Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations is defined as the relationship to find volume of tank when we have prior information of power required, mean velocity gradient and dynamic viscosity. Volume of Tank is denoted by V symbol.

How to evaluate Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations using this online evaluator? To use this online evaluator for Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations, enter Power Requirement (P), Mean Velocity Gradient (G) & Dynamic Viscosity viscosity) and hit the calculate button.

FAQs on Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations

What is the formula to find Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations?
The formula of Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations is expressed as Volume of Tank = (Power Requirement/((Mean Velocity Gradient)^2*Dynamic Viscosity)). Here is an example- 735.2941 = (3000/((2)^2*83.333)).
How to calculate Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations?
With Power Requirement (P), Mean Velocity Gradient (G) & Dynamic Viscosity viscosity) we can find Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations using the formula - Volume of Tank = (Power Requirement/((Mean Velocity Gradient)^2*Dynamic Viscosity)).
What are the other ways to Calculate Volume of Tank?
Here are the different ways to Calculate Volume of Tank-
  • Volume of Tank=(Power Requirement/((Mean Velocity Gradient)^2*Dynamic Viscosity))OpenImg
  • Volume of Tank=(Retention Time*Flow Rate of Secondary Effluent)/Time in Min Per DayOpenImg
  • Volume of Tank=(Power Requirement/((Mean Velocity Gradient)^2*Dynamic Viscosity))OpenImg
Can the Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations be negative?
No, the Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations, measured in Volume cannot be negative.
Which unit is used to measure Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations?
Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations is usually measured using the Cubic Meter[m³] for Volume. Cubic Centimeter[m³], Cubic Millimeter[m³], Liter[m³] are the few other units in which Volume of Mixing Tank given Power Requirement for Rapid Mixing Operations can be measured.
Copied!