Volume Of Conductor the 3-dimensional space enclosed by a conductor material. Check FAQs
V=3.5AL
V - Volume Of Conductor?A - Area of Underground AC Wire?L - Length of Underground AC Wire?

Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US) Example

With values
With units
Only example

Here is how the Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US) equation looks like with Values.

Here is how the Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US) equation looks like with Units.

Here is how the Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US) equation looks like.

107.52Edit=3.51.28Edit24Edit
You are here -

Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US) Solution

Follow our step by step solution on how to calculate Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US)?

FIRST Step Consider the formula
V=3.5AL
Next Step Substitute values of Variables
V=3.51.2824m
Next Step Prepare to Evaluate
V=3.51.2824
LAST Step Evaluate
V=107.52

Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US) Formula Elements

Variables
Volume Of Conductor
Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Area of Underground AC Wire
Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other Formulas to find Volume Of Conductor

​Go Volume of Conductor Material using Load Current (3 Phase 4 Wire US)
V=18ρ(I2)L22Ploss
​Go Volume of Conductor Material when K is Given(3 Phase 4 Wire US)
V=K1.75cos(Φ)2
​Go Volume of Conductor Material (3 Phase 4 Wire US)
V=7ρ(P2)L2Ploss(Vm2)(cos(Φ)2)
​Go Volume of Conductor Material when Resistance is Given(3 Phase 4 Wire US)
V=7RA(P2)(L)Ploss(Vm2)(cos(Φ)2)

Other formulas in Wire Parameters category

​Go Area of X-Section using Volume of Conductor Material (3 Phase 4 Wire US)
A=V(3.5)L
​Go Line Losses using Volume of Conductor Material (3 Phase 4 Wire US)
Ploss=7(P)2ρ(L)2(Vmcos(Φ))2V
​Go Constant using Volume of Conductor Material (3 Phase 4 Wire US)
K=V(cos(Φ))21.75
​Go Angle using Load Current (3 Phase 4 Wire US)
Φ=acos(6P3VmI)

How to Evaluate Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US)?

Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US) evaluator uses Volume Of Conductor = 3.5*Area of Underground AC Wire*Length of Underground AC Wire to evaluate the Volume Of Conductor, The Volume of Conductor Material when Area and Length is Given(3 phase 4 wire US) formula is defined as the 3-dimensional space enclosed by a conductor material of a three-phase four-wire earthed underground system. Volume Of Conductor is denoted by V symbol.

How to evaluate Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US) using this online evaluator? To use this online evaluator for Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US), enter Area of Underground AC Wire (A) & Length of Underground AC Wire (L) and hit the calculate button.

FAQs on Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US)

What is the formula to find Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US)?
The formula of Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US) is expressed as Volume Of Conductor = 3.5*Area of Underground AC Wire*Length of Underground AC Wire. Here is an example- 107.52 = 3.5*1.28*24.
How to calculate Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US)?
With Area of Underground AC Wire (A) & Length of Underground AC Wire (L) we can find Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US) using the formula - Volume Of Conductor = 3.5*Area of Underground AC Wire*Length of Underground AC Wire.
What are the other ways to Calculate Volume Of Conductor?
Here are the different ways to Calculate Volume Of Conductor-
  • Volume Of Conductor=18*Resistivity*(Current Underground AC^2)*(Length of Underground AC Wire^2)/(2*Line Losses)OpenImg
  • Volume Of Conductor=Constant Underground AC*1.75/(cos(Phase Difference)^2)OpenImg
  • Volume Of Conductor=7*Resistivity*(Power Transmitted^2)*(Length of Underground AC Wire^2)/(Line Losses*(Maximum Voltage Underground AC^2)*(cos(Phase Difference)^2))OpenImg
Can the Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US) be negative?
No, the Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US), measured in Volume cannot be negative.
Which unit is used to measure Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US)?
Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US) is usually measured using the Cubic Meter[m³] for Volume. Cubic Centimeter[m³], Cubic Millimeter[m³], Liter[m³] are the few other units in which Volume of Conductor Material when Area and Length is Given(3 Phase 4 Wire US) can be measured.
Copied!