Fx Copy
LaTeX Copy
Volume Of Conductor the 3-dimensional space enclosed by a conductor material. Check FAQs
V=4AR1(P2)(l)Pline(Vm2)
V - Volume Of Conductor?A - Area of underground dc wire?R1 - Resistance underground DC?P - Power Transmitted?l - Length of Wire DC?Pline - Line Losses?Vm - Maximum Voltage?

Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US) Example

With values
With units
Only example

Here is how the Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US) equation looks like with Values.

Here is how the Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US) equation looks like with Units.

Here is how the Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US) equation looks like.

853.3333Edit=40.32Edit5Edit(300Edit2)(3.2Edit)0.6Edit(60Edit2)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US)

Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US) Solution

Follow our step by step solution on how to calculate Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US)?

FIRST Step Consider the formula
V=4AR1(P2)(l)Pline(Vm2)
Next Step Substitute values of Variables
V=40.325Ω(300W2)(3.2m)0.6W(60V2)
Next Step Prepare to Evaluate
V=40.325(3002)(3.2)0.6(602)
Next Step Evaluate
V=853.333333333333
LAST Step Rounding Answer
V=853.3333

Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US) Formula Elements

Variables
Volume Of Conductor
Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Symbol: V
Measurement: VolumeUnit:
Note: Value can be positive or negative.
Area of underground dc wire
The Area of underground dc wire is the amount of two-dimensional space taken up by an object.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.
Resistance underground DC
Resistance underground DC is defined as the time rate of flow of charge through a cross-sectional area.
Symbol: R1
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Power Transmitted
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Length of Wire DC
Length of Wire DC is the measurement or extent of something from end to end.
Symbol: l
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Line Losses
Line Losses is defined as the losses that are produced in the line.
Symbol: Pline
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Maximum Voltage
Maximum Voltage the highest voltage rating for electrical devices.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.

Other Formulas to find Volume Of Conductor

​Go Volume of Conductor Material (2-Wire Mid-Point DC US)
V=4ρ(P2)l2Pline(Vm2)
​Go Volume of Conductor Material using Area and Length (2-Wire Mid-Point DC US)
V=2Al

Other formulas in Wire Parameters category

​Go Line Losses using Area of X-Section (2-Wire Mid-Point Earthed DC US)
Pline=2ρl(P2)A(Vm2cos(θ)2)
​Go Line Losses using Volume of Conductor Material (2-Wire Mid-Point DC US)
Pline=4ρP2l2Vm2V

How to Evaluate Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US)?

Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US) evaluator uses Volume Of Conductor = (4*Area of underground dc wire*Resistance underground DC*(Power Transmitted^2)*(Length of Wire DC))/(Line Losses*(Maximum Voltage^2)) to evaluate the Volume Of Conductor, The Volume of Conductor Material using Resistance (2-wire Mid-point DC US) formula is defined as the 3-dimensional space enclosed by a conductor material of a DC two-wire mid-point underground system. Volume Of Conductor is denoted by V symbol.

How to evaluate Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US) using this online evaluator? To use this online evaluator for Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US), enter Area of underground dc wire (A), Resistance underground DC (R1), Power Transmitted (P), Length of Wire DC (l), Line Losses (Pline) & Maximum Voltage (Vm) and hit the calculate button.

FAQs on Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US)

What is the formula to find Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US)?
The formula of Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US) is expressed as Volume Of Conductor = (4*Area of underground dc wire*Resistance underground DC*(Power Transmitted^2)*(Length of Wire DC))/(Line Losses*(Maximum Voltage^2)). Here is an example- 853.3333 = (4*0.32*5*(300^2)*(3.2))/(0.6*(60^2)).
How to calculate Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US)?
With Area of underground dc wire (A), Resistance underground DC (R1), Power Transmitted (P), Length of Wire DC (l), Line Losses (Pline) & Maximum Voltage (Vm) we can find Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US) using the formula - Volume Of Conductor = (4*Area of underground dc wire*Resistance underground DC*(Power Transmitted^2)*(Length of Wire DC))/(Line Losses*(Maximum Voltage^2)).
What are the other ways to Calculate Volume Of Conductor?
Here are the different ways to Calculate Volume Of Conductor-
  • Volume Of Conductor=4*Resistivity*(Power Transmitted^2)*(Length of Wire DC^2)/(Line Losses*(Maximum Voltage^2))OpenImg
  • Volume Of Conductor=2*Area of underground dc wire*Length of Wire DCOpenImg
  • Volume Of Conductor=4*Resistivity*(Current underground DC^2)*(Length of Wire DC^2)/(Line Losses)OpenImg
Can the Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US) be negative?
Yes, the Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US), measured in Volume can be negative.
Which unit is used to measure Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US)?
Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US) is usually measured using the Cubic Meter[m³] for Volume. Cubic Centimeter[m³], Cubic Millimeter[m³], Liter[m³] are the few other units in which Volume of Conductor Material using Resistance (2-Wire Mid-Point DC US) can be measured.
Copied!