Volume Of Conductor the 3-dimensional space enclosed by a conductor material. Check FAQs
V=(IL)24ρPloss
V - Volume Of Conductor?I - Current Underground AC?L - Length of Underground AC Wire?ρ - Resistivity?Ploss - Line Losses?

Volume of Conductor Material using Load Current (2 Phase 4 Wire US) Example

With values
With units
Only example

Here is how the Volume of Conductor Material using Load Current (2 Phase 4 Wire US) equation looks like with Values.

Here is how the Volume of Conductor Material using Load Current (2 Phase 4 Wire US) equation looks like with Units.

Here is how the Volume of Conductor Material using Load Current (2 Phase 4 Wire US) equation looks like.

1.1882Edit=(9Edit24Edit)241.7E-5Edit2.67Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Volume of Conductor Material using Load Current (2 Phase 4 Wire US)

Volume of Conductor Material using Load Current (2 Phase 4 Wire US) Solution

Follow our step by step solution on how to calculate Volume of Conductor Material using Load Current (2 Phase 4 Wire US)?

FIRST Step Consider the formula
V=(IL)24ρPloss
Next Step Substitute values of Variables
V=(9A24m)241.7E-5Ω*m2.67W
Next Step Prepare to Evaluate
V=(924)241.7E-52.67
Next Step Evaluate
V=1.18824269662921
LAST Step Rounding Answer
V=1.1882

Volume of Conductor Material using Load Current (2 Phase 4 Wire US) Formula Elements

Variables
Volume Of Conductor
Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Current Underground AC
Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.

Other Formulas to find Volume Of Conductor

​Go Volume of Conductor Material (2 Phase 4 Wire US)
V=2AL
​Go Volume of Conductor Material Main(2 Phase 4 Wire US)
V=8(P2)ρL2Ploss(Vm2)(cos(Φ)2)
​Go Volume of Conductor Material using Constant(2 Phase 4 Wire US)
V=2Kcos(Φ)2
​Go Volume of Conductor Material using Load Current(2 Phase 4 Wire US)
V=16ρ(L2)I2Ploss

Other formulas in Wire Parameters category

​Go Line Losses using Area of X-Section (2 Phase 4 Wire US)
Ploss=4ρLP2A(Vm2)(cos(Φ)2)
​Go Line Losses (2 Phase 4 Wire US)
Ploss=2(I2)R
​Go Length using Line Losses (2 Phase 4 Wire US)
L=PlossA2(I2)ρ
​Go Length using Area of X-Section (2 Phase 4 Wire US)
L=APloss(Vm2)(cos(Φ))24ρ(P2)

How to Evaluate Volume of Conductor Material using Load Current (2 Phase 4 Wire US)?

Volume of Conductor Material using Load Current (2 Phase 4 Wire US) evaluator uses Volume Of Conductor = (Current Underground AC*Length of Underground AC Wire)^2*4*Resistivity/Line Losses to evaluate the Volume Of Conductor, The Volume of Conductor Material using Load Current (2 phase 4 wire US) formula is defined as the 3-dimensional space enclosed by a conductor material of a two-phase four-wire system. Volume Of Conductor is denoted by V symbol.

How to evaluate Volume of Conductor Material using Load Current (2 Phase 4 Wire US) using this online evaluator? To use this online evaluator for Volume of Conductor Material using Load Current (2 Phase 4 Wire US), enter Current Underground AC (I), Length of Underground AC Wire (L), Resistivity (ρ) & Line Losses (Ploss) and hit the calculate button.

FAQs on Volume of Conductor Material using Load Current (2 Phase 4 Wire US)

What is the formula to find Volume of Conductor Material using Load Current (2 Phase 4 Wire US)?
The formula of Volume of Conductor Material using Load Current (2 Phase 4 Wire US) is expressed as Volume Of Conductor = (Current Underground AC*Length of Underground AC Wire)^2*4*Resistivity/Line Losses. Here is an example- 1.188243 = (9*24)^2*4*1.7E-05/2.67.
How to calculate Volume of Conductor Material using Load Current (2 Phase 4 Wire US)?
With Current Underground AC (I), Length of Underground AC Wire (L), Resistivity (ρ) & Line Losses (Ploss) we can find Volume of Conductor Material using Load Current (2 Phase 4 Wire US) using the formula - Volume Of Conductor = (Current Underground AC*Length of Underground AC Wire)^2*4*Resistivity/Line Losses.
What are the other ways to Calculate Volume Of Conductor?
Here are the different ways to Calculate Volume Of Conductor-
  • Volume Of Conductor=2*Area of Underground AC Wire*Length of Underground AC WireOpenImg
  • Volume Of Conductor=8*(Power Transmitted^2)*Resistivity*(Length of Underground AC Wire^2)/(Line Losses*(Maximum Voltage Underground AC^2)*(cos(Phase Difference)^2))OpenImg
  • Volume Of Conductor=2*Constant Underground AC/(cos(Phase Difference)^2)OpenImg
Can the Volume of Conductor Material using Load Current (2 Phase 4 Wire US) be negative?
No, the Volume of Conductor Material using Load Current (2 Phase 4 Wire US), measured in Volume cannot be negative.
Which unit is used to measure Volume of Conductor Material using Load Current (2 Phase 4 Wire US)?
Volume of Conductor Material using Load Current (2 Phase 4 Wire US) is usually measured using the Cubic Meter[m³] for Volume. Cubic Centimeter[m³], Cubic Millimeter[m³], Liter[m³] are the few other units in which Volume of Conductor Material using Load Current (2 Phase 4 Wire US) can be measured.