Volume Of Conductor the 3-dimensional space enclosed by a conductor material. Check FAQs
V=(2+2)2ρ(L2)I2Ploss
V - Volume Of Conductor?ρ - Resistivity?L - Length of Underground AC Wire?I - Current Underground AC?Ploss - Line Losses?

Volume of Conductor Material using Load Current (2 Phase 3 Wire US) Example

With values
With units
Only example

Here is how the Volume of Conductor Material using Load Current (2 Phase 3 Wire US) equation looks like with Values.

Here is how the Volume of Conductor Material using Load Current (2 Phase 3 Wire US) equation looks like with Units.

Here is how the Volume of Conductor Material using Load Current (2 Phase 3 Wire US) equation looks like.

3.4628Edit=(2+2)21.7E-5Edit(24Edit2)9Edit22.67Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Volume of Conductor Material using Load Current (2 Phase 3 Wire US)

Volume of Conductor Material using Load Current (2 Phase 3 Wire US) Solution

Follow our step by step solution on how to calculate Volume of Conductor Material using Load Current (2 Phase 3 Wire US)?

FIRST Step Consider the formula
V=(2+2)2ρ(L2)I2Ploss
Next Step Substitute values of Variables
V=(2+2)21.7E-5Ω*m(24m2)9A22.67W
Next Step Prepare to Evaluate
V=(2+2)21.7E-5(242)922.67
Next Step Evaluate
V=3.46279298190763
LAST Step Rounding Answer
V=3.4628

Volume of Conductor Material using Load Current (2 Phase 3 Wire US) Formula Elements

Variables
Functions
Volume Of Conductor
Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Current Underground AC
Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Volume Of Conductor

​Go Volume of Conductor Material using Area and Length(2 Phase 3 Wire US)
V=(2AL)+(2AL)
​Go Volume of Conductor Material using Constant(2 Phase 3 Wire US)
V=2.194Kcos(Φ)2
​Go Volume of Conductor Material using Resistance (2 Phase 3 Wire US)
V=(2+2)2(P2)RALPloss(Vm2)(cos(Φ))2
​Go Volume of Conductor Material (2 Phase 3 Wire US)
V=((2+2)2)(P2)ρL2Ploss(Vm2)(cos(Φ)2)

Other formulas in Wire Parameters category

​Go Line Losses using Volume of Conductor Material (2 Phase 3 Wire US)
Ploss=((2+2)P)2ρ(L)2(Vmcos(Φ))2V
​Go Length using Volume of Conductor Material (2 Phase 3 Wire US)
L=VPloss(cos(Φ)Vm)2ρ((2+2)P2)
​Go Constant using Volume of Conductor Material (2 Phase 3 Wire US)
K=V(cos(Φ))22.914
​Go Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US)
A=V(2+2)L

How to Evaluate Volume of Conductor Material using Load Current (2 Phase 3 Wire US)?

Volume of Conductor Material using Load Current (2 Phase 3 Wire US) evaluator uses Volume Of Conductor = (2+sqrt(2))^2*Resistivity*(Length of Underground AC Wire^2)*(Current Underground AC^2)/Line Losses to evaluate the Volume Of Conductor, The Volume of Conductor Material using Load Current (2 phase 3 wire US) formula is defined as the 3-dimensional space enclosed by a conductor material of a 2-phase 3-wire underground system. Volume Of Conductor is denoted by V symbol.

How to evaluate Volume of Conductor Material using Load Current (2 Phase 3 Wire US) using this online evaluator? To use this online evaluator for Volume of Conductor Material using Load Current (2 Phase 3 Wire US), enter Resistivity (ρ), Length of Underground AC Wire (L), Current Underground AC (I) & Line Losses (Ploss) and hit the calculate button.

FAQs on Volume of Conductor Material using Load Current (2 Phase 3 Wire US)

What is the formula to find Volume of Conductor Material using Load Current (2 Phase 3 Wire US)?
The formula of Volume of Conductor Material using Load Current (2 Phase 3 Wire US) is expressed as Volume Of Conductor = (2+sqrt(2))^2*Resistivity*(Length of Underground AC Wire^2)*(Current Underground AC^2)/Line Losses. Here is an example- 3.462793 = (2+sqrt(2))^2*1.7E-05*(24^2)*(9^2)/2.67.
How to calculate Volume of Conductor Material using Load Current (2 Phase 3 Wire US)?
With Resistivity (ρ), Length of Underground AC Wire (L), Current Underground AC (I) & Line Losses (Ploss) we can find Volume of Conductor Material using Load Current (2 Phase 3 Wire US) using the formula - Volume Of Conductor = (2+sqrt(2))^2*Resistivity*(Length of Underground AC Wire^2)*(Current Underground AC^2)/Line Losses. This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Volume Of Conductor?
Here are the different ways to Calculate Volume Of Conductor-
  • Volume Of Conductor=(2*Area of Underground AC Wire*Length of Underground AC Wire)+(sqrt(2)*Area of Underground AC Wire*Length of Underground AC Wire)OpenImg
  • Volume Of Conductor=2.194*Constant Underground AC/(cos(Phase Difference)^2)OpenImg
  • Volume Of Conductor=((2+sqrt(2))^2*(Power Transmitted^2)*Resistance Underground AC*Area of Underground AC Wire*Length of Underground AC Wire)/(Line Losses*(Maximum Voltage Underground AC^2)*(cos(Phase Difference))^2)OpenImg
Can the Volume of Conductor Material using Load Current (2 Phase 3 Wire US) be negative?
No, the Volume of Conductor Material using Load Current (2 Phase 3 Wire US), measured in Volume cannot be negative.
Which unit is used to measure Volume of Conductor Material using Load Current (2 Phase 3 Wire US)?
Volume of Conductor Material using Load Current (2 Phase 3 Wire US) is usually measured using the Cubic Meter[m³] for Volume. Cubic Centimeter[m³], Cubic Millimeter[m³], Liter[m³] are the few other units in which Volume of Conductor Material using Load Current (2 Phase 3 Wire US) can be measured.
Copied!