Volume Of Conductor the 3-dimensional space enclosed by a conductor material. Check FAQs
V=4(I2)ρL2Ploss
V - Volume Of Conductor?I - Current Underground AC?ρ - Resistivity?L - Length of Underground AC Wire?Ploss - Line Losses?

Volume of Conductor Material using Load Current (1-Phase 2-Wire US) Example

With values
With units
Only example

Here is how the Volume of Conductor Material using Load Current (1-Phase 2-Wire US) equation looks like with Values.

Here is how the Volume of Conductor Material using Load Current (1-Phase 2-Wire US) equation looks like with Units.

Here is how the Volume of Conductor Material using Load Current (1-Phase 2-Wire US) equation looks like.

1.1882Edit=4(9Edit2)1.7E-5Edit24Edit22.67Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Volume of Conductor Material using Load Current (1-Phase 2-Wire US)

Volume of Conductor Material using Load Current (1-Phase 2-Wire US) Solution

Follow our step by step solution on how to calculate Volume of Conductor Material using Load Current (1-Phase 2-Wire US)?

FIRST Step Consider the formula
V=4(I2)ρL2Ploss
Next Step Substitute values of Variables
V=4(9A2)1.7E-5Ω*m24m22.67W
Next Step Prepare to Evaluate
V=4(92)1.7E-52422.67
Next Step Evaluate
V=1.18824269662921
LAST Step Rounding Answer
V=1.1882

Volume of Conductor Material using Load Current (1-Phase 2-Wire US) Formula Elements

Variables
Volume Of Conductor
Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Current Underground AC
Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Line Losses
Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.

Other Formulas to find Volume Of Conductor

​Go Voltage of Conductor Material (1-Phase 2-Wire US)
V=2K(cos(Φ))2
​Go Volume of Conductor Material using Area of X-Section (1-Phase 2-Wire US)
V=AL2
​Go Volume of Conductor Material using Line Losses (1-Phase 2-Wire US)
V=8ρ(PL)2Ploss(Vmcos(Φ))2
​Go Volume of Conductor Material using Constant (1-Phase 2-Wire US)
V=2K(cos(Φ))2

Other formulas in Wire Parameters category

​Go Area of X-Section (1-Phase 2-Wire US)
A=(4)ρL(P)2Ploss(Vmcos(Φ))2
​Go Constant (1-Phase 2-Wire US)
K=4ρ(PL)2Ploss(Vm)2
​Go Area of X-Section using Volume of Conductor Material (1-Phase 2-Wire US)
A=V2L
​Go Length using Area of X-Section (1-Phase 2-Wire US)
L=APloss(Vmcos(Φ))24(P2)ρ

How to Evaluate Volume of Conductor Material using Load Current (1-Phase 2-Wire US)?

Volume of Conductor Material using Load Current (1-Phase 2-Wire US) evaluator uses Volume Of Conductor = 4*(Current Underground AC^2)*Resistivity*(Length of Underground AC Wire^2)/(Line Losses) to evaluate the Volume Of Conductor, The Volume of Conductor Material using Load Current (1-Phase 2-Wire US) formula is defined as the 3-dimensional space enclosed by a conductor material of a single-phase two-wire overhead system. Volume Of Conductor is denoted by V symbol.

How to evaluate Volume of Conductor Material using Load Current (1-Phase 2-Wire US) using this online evaluator? To use this online evaluator for Volume of Conductor Material using Load Current (1-Phase 2-Wire US), enter Current Underground AC (I), Resistivity (ρ), Length of Underground AC Wire (L) & Line Losses (Ploss) and hit the calculate button.

FAQs on Volume of Conductor Material using Load Current (1-Phase 2-Wire US)

What is the formula to find Volume of Conductor Material using Load Current (1-Phase 2-Wire US)?
The formula of Volume of Conductor Material using Load Current (1-Phase 2-Wire US) is expressed as Volume Of Conductor = 4*(Current Underground AC^2)*Resistivity*(Length of Underground AC Wire^2)/(Line Losses). Here is an example- 1.188243 = 4*(9^2)*1.7E-05*(24^2)/(2.67).
How to calculate Volume of Conductor Material using Load Current (1-Phase 2-Wire US)?
With Current Underground AC (I), Resistivity (ρ), Length of Underground AC Wire (L) & Line Losses (Ploss) we can find Volume of Conductor Material using Load Current (1-Phase 2-Wire US) using the formula - Volume Of Conductor = 4*(Current Underground AC^2)*Resistivity*(Length of Underground AC Wire^2)/(Line Losses).
What are the other ways to Calculate Volume Of Conductor?
Here are the different ways to Calculate Volume Of Conductor-
  • Volume Of Conductor=2*Constant Underground AC/(cos(Phase Difference))^2OpenImg
  • Volume Of Conductor=Area of Underground AC Wire*Length of Underground AC Wire*2OpenImg
  • Volume Of Conductor=8*Resistivity*(Power Transmitted*Length of Underground AC Wire)^2/(Line Losses*(Maximum Voltage Underground AC*cos(Phase Difference))^2)OpenImg
Can the Volume of Conductor Material using Load Current (1-Phase 2-Wire US) be negative?
No, the Volume of Conductor Material using Load Current (1-Phase 2-Wire US), measured in Volume cannot be negative.
Which unit is used to measure Volume of Conductor Material using Load Current (1-Phase 2-Wire US)?
Volume of Conductor Material using Load Current (1-Phase 2-Wire US) is usually measured using the Cubic Meter[m³] for Volume. Cubic Centimeter[m³], Cubic Millimeter[m³], Liter[m³] are the few other units in which Volume of Conductor Material using Load Current (1-Phase 2-Wire US) can be measured.
Copied!