Fx Copy
LaTeX Copy
Volume Of Conductor the 3-dimensional space enclosed by a conductor material. Check FAQs
V=16ρ(L2)I2Ploss
V - Volume Of Conductor?ρ - Resistivity?L - Length of Underground AC Wire?I - Current Underground AC?Ploss - Line Losses?

Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed) Example

With values
With units
Only example

Here is how the Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed) equation looks like with Values.

Here is how the Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed) equation looks like with Units.

Here is how the Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed) equation looks like.

4.753Edit=161.7E-5Edit(24Edit2)9Edit22.67Edit
You are here -

Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed) Solution

Follow our step by step solution on how to calculate Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed)?

FIRST Step Consider the formula
V=16ρ(L2)I2Ploss
Next Step Substitute values of Variables
V=161.7E-5Ω*m(24m2)9A22.67W
Next Step Prepare to Evaluate
V=161.7E-5(242)922.67
Next Step Evaluate
V=4.75297078651685
LAST Step Rounding Answer
V=4.753

Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed) Formula Elements

Variables
Volume Of Conductor
Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Current Underground AC
Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.

Other Formulas to find Volume Of Conductor

​Go Volume of Conductor Material (1-Phase 2-Wire Mid-Point Earthed)
V=8ρ(P2)L2Ploss(Vm2)(cos(Φ)2)
​Go Volume of Conductor Material using Area and Length(1-Phase 2-Wire Mid-Point US)
V=AL2
​Go Volume of Conductor Material using Constant(1-Phase 2-Wire Mid-Point Earthed)
V=2Kcos(Φ)2
​Go Volume of Conductor Material using Resistance (1-Phase 2-Wire Mid-Point Earthed)
V=8(P2)RALPloss(Vm2)(cos(Φ))2

Other formulas in Wire Parameters category

​Go Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)
A=4ρLP2Ploss((Vmcos(Φ))2)
​Go Length using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
L=PlossA2ρ(I2)
​Go Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)
L=APloss(Vmcos(Φ))24(P2)ρ
​Go Area using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
A=2ρLPloss(I2)

How to Evaluate Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed)?

Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed) evaluator uses Volume Of Conductor = 16*Resistivity*(Length of Underground AC Wire^2)*(Current Underground AC^2)/Line Losses to evaluate the Volume Of Conductor, The Volume of Conductor Material using Load Current (1-phase 2-wire Mid-point Earthed) formula is defined as the 3-dimensional space enclosed by a conductor material of a 1-phase 2-wire Mid-point Earthed underground system. Volume Of Conductor is denoted by V symbol.

How to evaluate Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed) using this online evaluator? To use this online evaluator for Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed), enter Resistivity (ρ), Length of Underground AC Wire (L), Current Underground AC (I) & Line Losses (Ploss) and hit the calculate button.

FAQs on Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed)

What is the formula to find Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed)?
The formula of Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed) is expressed as Volume Of Conductor = 16*Resistivity*(Length of Underground AC Wire^2)*(Current Underground AC^2)/Line Losses. Here is an example- 4.752971 = 16*1.7E-05*(24^2)*(9^2)/2.67.
How to calculate Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed)?
With Resistivity (ρ), Length of Underground AC Wire (L), Current Underground AC (I) & Line Losses (Ploss) we can find Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed) using the formula - Volume Of Conductor = 16*Resistivity*(Length of Underground AC Wire^2)*(Current Underground AC^2)/Line Losses.
What are the other ways to Calculate Volume Of Conductor?
Here are the different ways to Calculate Volume Of Conductor-
  • Volume Of Conductor=8*Resistivity*(Power Transmitted^2)*(Length of Underground AC Wire^2)/(Line Losses*(Maximum Voltage Underground AC^2)*(cos(Phase Difference)^2))OpenImg
  • Volume Of Conductor=Area of Underground AC Wire*Length of Underground AC Wire*2OpenImg
  • Volume Of Conductor=2*Constant Underground AC/(cos(Phase Difference)^2)OpenImg
Can the Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed) be negative?
No, the Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed), measured in Volume cannot be negative.
Which unit is used to measure Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed)?
Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed) is usually measured using the Cubic Meter[m³] for Volume. Cubic Centimeter[m³], Cubic Millimeter[m³], Liter[m³] are the few other units in which Volume of Conductor Material using Load Current (1-Phase 2-Wire Mid-Point Earthed) can be measured.
Copied!