Volume of Conductor is the total volume of the material used to make the conductor of an overhead ac line. Check FAQs
V=2ρ(PL)2Ploss(Vmcos(Φ))2
V - Volume of Conductor?ρ - Resistivity?P - Power Transmitted?L - Length of Overhead AC Wire?Ploss - Line Losses?Vm - Maximum Voltage Overhead AC?Φ - Phase Difference?

Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS) Example

With values
With units
Only example

Here is how the Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS) equation looks like with Values.

Here is how the Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS) equation looks like with Units.

Here is how the Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS) equation looks like.

0.1283Edit=21.7E-5Edit(890Edit10.63Edit)28.23Edit(62Editcos(30Edit))2
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS)

Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS) Solution

Follow our step by step solution on how to calculate Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS)?

FIRST Step Consider the formula
V=2ρ(PL)2Ploss(Vmcos(Φ))2
Next Step Substitute values of Variables
V=21.7E-5Ω*m(890W10.63m)28.23W(62Vcos(30°))2
Next Step Convert Units
V=21.7E-5Ω*m(890W10.63m)28.23W(62Vcos(0.5236rad))2
Next Step Prepare to Evaluate
V=21.7E-5(89010.63)28.23(62cos(0.5236))2
Next Step Evaluate
V=0.128256971784572
LAST Step Rounding Answer
V=0.1283

Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS) Formula Elements

Variables
Functions
Volume of Conductor
Volume of Conductor is the total volume of the material used to make the conductor of an overhead ac line.
Symbol: V
Measurement: VolumeUnit:
Note: Value can be positive or negative.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Power Transmitted
Power Transmitted is defined as the product of current and voltage phasor in a overhead ac line at the receiving end.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Length of Overhead AC Wire
Length of Overhead AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Line Losses
Line Losses is defined as the total losses occurring in an Overhead AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Maximum Voltage Overhead AC
Maximum Voltage Overhead AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Phase Difference
Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Symbol: Φ
Measurement: AngleUnit: °
Note: Value should be greater than 0.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)

Other Formulas to find Volume of Conductor

​Go Volume of Conductor Material(2-Phase 4-Wire OS)
V=(4)AL
​Go Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS)
V=(4)AL

Other formulas in Wire Parameters category

​Go Line Losses(2-Phase 4-Wire OS)
Ploss=(4)((I)2)R
​Go Constant(2-Phase 4-Wire OS)
K=4(P2)ρLPloss(Vac2)

How to Evaluate Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS)?

Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS) evaluator uses Volume of Conductor = 2*Resistivity*(Power Transmitted*Length of Overhead AC Wire)^2/(Line Losses*(Maximum Voltage Overhead AC*cos(Phase Difference))^2) to evaluate the Volume of Conductor, The Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS) formula is defined as the 3-dimensional space enclosed by a conductor material of a two-phase four-wire overhead system. Volume of Conductor is denoted by V symbol.

How to evaluate Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS) using this online evaluator? To use this online evaluator for Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS), enter Resistivity (ρ), Power Transmitted (P), Length of Overhead AC Wire (L), Line Losses (Ploss), Maximum Voltage Overhead AC (Vm) & Phase Difference (Φ) and hit the calculate button.

FAQs on Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS)

What is the formula to find Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS)?
The formula of Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS) is expressed as Volume of Conductor = 2*Resistivity*(Power Transmitted*Length of Overhead AC Wire)^2/(Line Losses*(Maximum Voltage Overhead AC*cos(Phase Difference))^2). Here is an example- 0.128257 = 2*1.7E-05*(890*10.63)^2/(8.23*(62*cos(0.5235987755982))^2).
How to calculate Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS)?
With Resistivity (ρ), Power Transmitted (P), Length of Overhead AC Wire (L), Line Losses (Ploss), Maximum Voltage Overhead AC (Vm) & Phase Difference (Φ) we can find Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS) using the formula - Volume of Conductor = 2*Resistivity*(Power Transmitted*Length of Overhead AC Wire)^2/(Line Losses*(Maximum Voltage Overhead AC*cos(Phase Difference))^2). This formula also uses Cosine (cos) function(s).
What are the other ways to Calculate Volume of Conductor?
Here are the different ways to Calculate Volume of Conductor-
  • Volume of Conductor=(4)*Area of Overhead AC Wire*Length of Overhead AC WireOpenImg
  • Volume of Conductor=(4)*Area of Overhead AC Wire*Length of Overhead AC WireOpenImg
  • Volume of Conductor=16*Resistivity*(Current Overhead AC*Length of Overhead AC Wire)^2/(Line Losses)OpenImg
Can the Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS) be negative?
Yes, the Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS), measured in Volume can be negative.
Which unit is used to measure Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS)?
Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS) is usually measured using the Cubic Meter[m³] for Volume. Cubic Centimeter[m³], Cubic Millimeter[m³], Liter[m³] are the few other units in which Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS) can be measured.
Copied!