Fx Copy
LaTeX Copy
Volume of Conductor is the total volume of the material used to make the conductor of an overhead ac line. Check FAQs
V=7K12(cos(Φ)2)
V - Volume of Conductor?K - Constant Overhead AC?Φ - Phase Difference?

Volume of Conductor Material using Constant(3-Phase 4-Wire OS) Example

With values
With units
Only example

Here is how the Volume of Conductor Material using Constant(3-Phase 4-Wire OS) equation looks like with Values.

Here is how the Volume of Conductor Material using Constant(3-Phase 4-Wire OS) equation looks like with Units.

Here is how the Volume of Conductor Material using Constant(3-Phase 4-Wire OS) equation looks like.

0.6922Edit=70.89Edit12(cos(30Edit)2)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Volume of Conductor Material using Constant(3-Phase 4-Wire OS)

Volume of Conductor Material using Constant(3-Phase 4-Wire OS) Solution

Follow our step by step solution on how to calculate Volume of Conductor Material using Constant(3-Phase 4-Wire OS)?

FIRST Step Consider the formula
V=7K12(cos(Φ)2)
Next Step Substitute values of Variables
V=70.8912(cos(30°)2)
Next Step Convert Units
V=70.8912(cos(0.5236rad)2)
Next Step Prepare to Evaluate
V=70.8912(cos(0.5236)2)
Next Step Evaluate
V=0.692222222222222
LAST Step Rounding Answer
V=0.6922

Volume of Conductor Material using Constant(3-Phase 4-Wire OS) Formula Elements

Variables
Functions
Volume of Conductor
Volume of Conductor is the total volume of the material used to make the conductor of an overhead ac line.
Symbol: V
Measurement: VolumeUnit:
Note: Value can be positive or negative.
Constant Overhead AC
Constant Overhead AC is defined as the constant of line of a Overhead supply system.
Symbol: K
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Phase Difference
Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Symbol: Φ
Measurement: AngleUnit: °
Note: Value should be greater than 0.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)

Other Formulas to find Volume of Conductor

​Go Volume of Conductor Material(3-Phase 4-Wire OS)
V=(3.5)AL

Other formulas in Wire Parameters category

​Go Area of X-Section(3-Phase 4-Wire OS)
A=2(P2)ρL((cos(Φ))2)Ploss3(Vm2)
​Go Constant(3-Phase 4-Wire OS)
K=4(P2)ρ(L2)Ploss(Vm2)
​Go Line Losses(3-Phase 4-Wire OS)
Ploss=(3)((I)2)R
​Go Length of Wire using Area of X-Section(3-Phase 4-Wire OS)
L=3A(Vm2)Ploss(cos(Φ))22ρ(P2)

How to Evaluate Volume of Conductor Material using Constant(3-Phase 4-Wire OS)?

Volume of Conductor Material using Constant(3-Phase 4-Wire OS) evaluator uses Volume of Conductor = 7*Constant Overhead AC/(12*(cos(Phase Difference)^2)) to evaluate the Volume of Conductor, The Volume of Conductor Material using Constant(3-phase 4-wire OS) formula is defined as the 3-dimensional space enclosed by a conductor material of a three-phase four-wire overhead system. Volume of Conductor is denoted by V symbol.

How to evaluate Volume of Conductor Material using Constant(3-Phase 4-Wire OS) using this online evaluator? To use this online evaluator for Volume of Conductor Material using Constant(3-Phase 4-Wire OS), enter Constant Overhead AC (K) & Phase Difference (Φ) and hit the calculate button.

FAQs on Volume of Conductor Material using Constant(3-Phase 4-Wire OS)

What is the formula to find Volume of Conductor Material using Constant(3-Phase 4-Wire OS)?
The formula of Volume of Conductor Material using Constant(3-Phase 4-Wire OS) is expressed as Volume of Conductor = 7*Constant Overhead AC/(12*(cos(Phase Difference)^2)). Here is an example- 0.692222 = 7*0.89/(12*(cos(0.5235987755982)^2)).
How to calculate Volume of Conductor Material using Constant(3-Phase 4-Wire OS)?
With Constant Overhead AC (K) & Phase Difference (Φ) we can find Volume of Conductor Material using Constant(3-Phase 4-Wire OS) using the formula - Volume of Conductor = 7*Constant Overhead AC/(12*(cos(Phase Difference)^2)). This formula also uses Cosine function(s).
What are the other ways to Calculate Volume of Conductor?
Here are the different ways to Calculate Volume of Conductor-
  • Volume of Conductor=(3.5)*Area of Overhead AC Wire*Length of Overhead AC WireOpenImg
Can the Volume of Conductor Material using Constant(3-Phase 4-Wire OS) be negative?
Yes, the Volume of Conductor Material using Constant(3-Phase 4-Wire OS), measured in Volume can be negative.
Which unit is used to measure Volume of Conductor Material using Constant(3-Phase 4-Wire OS)?
Volume of Conductor Material using Constant(3-Phase 4-Wire OS) is usually measured using the Cubic Meter[m³] for Volume. Cubic Centimeter[m³], Cubic Millimeter[m³], Liter[m³] are the few other units in which Volume of Conductor Material using Constant(3-Phase 4-Wire OS) can be measured.
Copied!