Fx Copy
LaTeX Copy
Volume Of Conductor the 3-dimensional space enclosed by a conductor material. Check FAQs
V=2.194Kcos(Φ)2
V - Volume Of Conductor?K - Constant Underground AC?Φ - Phase Difference?

Volume of Conductor Material using Constant(2 Phase 3 Wire US) Example

With values
With units
Only example

Here is how the Volume of Conductor Material using Constant(2 Phase 3 Wire US) equation looks like with Values.

Here is how the Volume of Conductor Material using Constant(2 Phase 3 Wire US) equation looks like with Units.

Here is how the Volume of Conductor Material using Constant(2 Phase 3 Wire US) equation looks like.

2.545Edit=2.1940.87Editcos(30Edit)2
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Volume of Conductor Material using Constant(2 Phase 3 Wire US)

Volume of Conductor Material using Constant(2 Phase 3 Wire US) Solution

Follow our step by step solution on how to calculate Volume of Conductor Material using Constant(2 Phase 3 Wire US)?

FIRST Step Consider the formula
V=2.194Kcos(Φ)2
Next Step Substitute values of Variables
V=2.1940.87cos(30°)2
Next Step Convert Units
V=2.1940.87cos(0.5236rad)2
Next Step Prepare to Evaluate
V=2.1940.87cos(0.5236)2
Next Step Evaluate
V=2.54504
LAST Step Rounding Answer
V=2.545

Volume of Conductor Material using Constant(2 Phase 3 Wire US) Formula Elements

Variables
Functions
Volume Of Conductor
Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Constant Underground AC
Constant Underground AC is defined as the constant of line of a Overhead supply system.
Symbol: K
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Phase Difference
Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Symbol: Φ
Measurement: AngleUnit: °
Note: Value should be greater than 0.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)

Other Formulas to find Volume Of Conductor

​Go Volume of Conductor Material using Area and Length(2 Phase 3 Wire US)
V=(2AL)+(2AL)
​Go Volume of Conductor Material using Load Current (2 Phase 3 Wire US)
V=(2+2)2ρ(L2)I2Ploss
​Go Volume of Conductor Material using Resistance (2 Phase 3 Wire US)
V=(2+2)2(P2)RALPloss(Vm2)(cos(Φ))2
​Go Volume of Conductor Material (2 Phase 3 Wire US)
V=((2+2)2)(P2)ρL2Ploss(Vm2)(cos(Φ)2)

Other formulas in Wire Parameters category

​Go Line Losses using Volume of Conductor Material (2 Phase 3 Wire US)
Ploss=((2+2)P)2ρ(L)2(Vmcos(Φ))2V
​Go Length using Volume of Conductor Material (2 Phase 3 Wire US)
L=VPloss(cos(Φ)Vm)2ρ((2+2)P2)
​Go Constant using Volume of Conductor Material (2 Phase 3 Wire US)
K=V(cos(Φ))22.914
​Go Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US)
A=V(2+2)L

How to Evaluate Volume of Conductor Material using Constant(2 Phase 3 Wire US)?

Volume of Conductor Material using Constant(2 Phase 3 Wire US) evaluator uses Volume Of Conductor = 2.194*Constant Underground AC/(cos(Phase Difference)^2) to evaluate the Volume Of Conductor, The Volume of Conductor Material using Constant(2 phase 3 wire US) formula is defined as the 3-dimensional space enclosed by a conductor material of a 1-phase 2-wire mid-point earthed system. Volume Of Conductor is denoted by V symbol.

How to evaluate Volume of Conductor Material using Constant(2 Phase 3 Wire US) using this online evaluator? To use this online evaluator for Volume of Conductor Material using Constant(2 Phase 3 Wire US), enter Constant Underground AC (K) & Phase Difference (Φ) and hit the calculate button.

FAQs on Volume of Conductor Material using Constant(2 Phase 3 Wire US)

What is the formula to find Volume of Conductor Material using Constant(2 Phase 3 Wire US)?
The formula of Volume of Conductor Material using Constant(2 Phase 3 Wire US) is expressed as Volume Of Conductor = 2.194*Constant Underground AC/(cos(Phase Difference)^2). Here is an example- 2.54504 = 2.194*0.87/(cos(0.5235987755982)^2).
How to calculate Volume of Conductor Material using Constant(2 Phase 3 Wire US)?
With Constant Underground AC (K) & Phase Difference (Φ) we can find Volume of Conductor Material using Constant(2 Phase 3 Wire US) using the formula - Volume Of Conductor = 2.194*Constant Underground AC/(cos(Phase Difference)^2). This formula also uses Cosine (cos) function(s).
What are the other ways to Calculate Volume Of Conductor?
Here are the different ways to Calculate Volume Of Conductor-
  • Volume Of Conductor=(2*Area of Underground AC Wire*Length of Underground AC Wire)+(sqrt(2)*Area of Underground AC Wire*Length of Underground AC Wire)OpenImg
  • Volume Of Conductor=(2+sqrt(2))^2*Resistivity*(Length of Underground AC Wire^2)*(Current Underground AC^2)/Line LossesOpenImg
  • Volume Of Conductor=((2+sqrt(2))^2*(Power Transmitted^2)*Resistance Underground AC*Area of Underground AC Wire*Length of Underground AC Wire)/(Line Losses*(Maximum Voltage Underground AC^2)*(cos(Phase Difference))^2)OpenImg
Can the Volume of Conductor Material using Constant(2 Phase 3 Wire US) be negative?
No, the Volume of Conductor Material using Constant(2 Phase 3 Wire US), measured in Volume cannot be negative.
Which unit is used to measure Volume of Conductor Material using Constant(2 Phase 3 Wire US)?
Volume of Conductor Material using Constant(2 Phase 3 Wire US) is usually measured using the Cubic Meter[m³] for Volume. Cubic Centimeter[m³], Cubic Millimeter[m³], Liter[m³] are the few other units in which Volume of Conductor Material using Constant(2 Phase 3 Wire US) can be measured.
Copied!