Fx Copy
LaTeX Copy
Volume of Conductor is the total volume of the material used to make the conductor of an overhead ac line. Check FAQs
V=(4)AL
V - Volume of Conductor?A - Area of Overhead AC Wire?L - Length of Overhead AC Wire?

Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS) Example

With values
With units
Only example

Here is how the Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS) equation looks like with Values.

Here is how the Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS) equation looks like with Units.

Here is how the Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS) equation looks like.

33.5908Edit=(4)0.79Edit10.63Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS)

Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS) Solution

Follow our step by step solution on how to calculate Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS)?

FIRST Step Consider the formula
V=(4)AL
Next Step Substitute values of Variables
V=(4)0.7910.63m
Next Step Prepare to Evaluate
V=(4)0.7910.63
LAST Step Evaluate
V=33.5908

Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS) Formula Elements

Variables
Volume of Conductor
Volume of Conductor is the total volume of the material used to make the conductor of an overhead ac line.
Symbol: V
Measurement: VolumeUnit:
Note: Value can be positive or negative.
Area of Overhead AC Wire
Area of Overhead AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Length of Overhead AC Wire
Length of Overhead AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other Formulas to find Volume of Conductor

​Go Volume of Conductor Material(2-Phase 4-Wire OS)
V=(4)AL
​Go Volume of Conductor Material using Line Losses (2-Phase 4-Wire OS)
V=2ρ(PL)2Ploss(Vmcos(Φ))2
​Go Volume of Conductor Material using Load Current (2-Phase 4-Wire OS)
V=16ρ(IL)2Ploss

Other formulas in Wire Parameters category

​Go Line Losses(2-Phase 4-Wire OS)
Ploss=(4)((I)2)R
​Go Constant(2-Phase 4-Wire OS)
K=4(P2)ρLPloss(Vac2)
​Go Area of X-Section(2-Phase 4-Wire OS)
A=(P2)ρL((cos(Φ))2)Ploss(Vm2)2
​Go Line Losses using Area of X-Section(2-Phase 4-Wire OS)
Ploss=Lρ(P2)2A(Vm2)((cos(Φ))2)

How to Evaluate Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS)?

Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS) evaluator uses Volume of Conductor = (4)*Area of Overhead AC Wire*Length of Overhead AC Wire to evaluate the Volume of Conductor, The Volume of Conductor Material using Area of X-section(2-phase 4-wire OS) formula is defined as the 3-dimensional space enclosed by a conductor material of a two-phase four-wire overhead system. Volume of Conductor is denoted by V symbol.

How to evaluate Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS) using this online evaluator? To use this online evaluator for Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS), enter Area of Overhead AC Wire (A) & Length of Overhead AC Wire (L) and hit the calculate button.

FAQs on Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS)

What is the formula to find Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS)?
The formula of Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS) is expressed as Volume of Conductor = (4)*Area of Overhead AC Wire*Length of Overhead AC Wire. Here is an example- 33.5908 = (4)*0.79*10.63.
How to calculate Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS)?
With Area of Overhead AC Wire (A) & Length of Overhead AC Wire (L) we can find Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS) using the formula - Volume of Conductor = (4)*Area of Overhead AC Wire*Length of Overhead AC Wire.
What are the other ways to Calculate Volume of Conductor?
Here are the different ways to Calculate Volume of Conductor-
  • Volume of Conductor=(4)*Area of Overhead AC Wire*Length of Overhead AC WireOpenImg
  • Volume of Conductor=2*Resistivity*(Power Transmitted*Length of Overhead AC Wire)^2/(Line Losses*(Maximum Voltage Overhead AC*cos(Phase Difference))^2)OpenImg
  • Volume of Conductor=16*Resistivity*(Current Overhead AC*Length of Overhead AC Wire)^2/(Line Losses)OpenImg
Can the Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS) be negative?
Yes, the Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS), measured in Volume can be negative.
Which unit is used to measure Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS)?
Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS) is usually measured using the Cubic Meter[m³] for Volume. Cubic Centimeter[m³], Cubic Millimeter[m³], Liter[m³] are the few other units in which Volume of Conductor Material using Area of X-Section(2-Phase 4-Wire OS) can be measured.
Copied!