Fx Copy
LaTeX Copy
Volume Of Conductor the 3-dimensional space enclosed by a conductor material. Check FAQs
V=4(P2)ρl2Pline(Vm2)
V - Volume Of Conductor?P - Power Transmitted?ρ - Resistivity?l - Length of Wire DC?Pline - Line Losses?Vm - Maximum Voltage?

Volume of Conductor Material (DC Two-Wire US) Example

With values
With units
Only example

Here is how the Volume of Conductor Material (DC Two-Wire US) equation looks like with Values.

Here is how the Volume of Conductor Material (DC Two-Wire US) equation looks like with Units.

Here is how the Volume of Conductor Material (DC Two-Wire US) equation looks like.

0.029Edit=4(300Edit2)1.7E-5Edit3.2Edit20.6Edit(60Edit2)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Volume of Conductor Material (DC Two-Wire US)

Volume of Conductor Material (DC Two-Wire US) Solution

Follow our step by step solution on how to calculate Volume of Conductor Material (DC Two-Wire US)?

FIRST Step Consider the formula
V=4(P2)ρl2Pline(Vm2)
Next Step Substitute values of Variables
V=4(300W2)1.7E-5Ω*m3.2m20.6W(60V2)
Next Step Prepare to Evaluate
V=4(3002)1.7E-53.220.6(602)
Next Step Evaluate
V=0.0290133333333333
LAST Step Rounding Answer
V=0.029

Volume of Conductor Material (DC Two-Wire US) Formula Elements

Variables
Volume Of Conductor
Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Symbol: V
Measurement: VolumeUnit:
Note: Value can be positive or negative.
Power Transmitted
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Wire DC
Length of Wire DC is the measurement or extent of something from end to end.
Symbol: l
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Line Losses
Line Losses is defined as the losses that are produced in the line.
Symbol: Pline
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Maximum Voltage
Maximum Voltage the highest voltage rating for electrical devices.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.

Other Formulas to find Volume Of Conductor

​Go Volume of Conductor Material using Area and Length(DC Two-Wire US)
V=Al2
​Go Volume of Conductor Material using Load Current (DC Two-Wire US)
V=4ρ(l2)C12Pline
​Go Volume of Conductor Material using Resistance (DC Two-Wire US)
V=4(P2)R1AlPline(Vm2)

Other formulas in Wire Parameters category

​Go Length using Area of X-Section (DC Two-Wire US)
l=APlineVm22ρ(P2)
​Go Length using Line Losses (DC Two-Wire US)
l=APline2ρ(C12)
​Go Area of X-Section (DC Two-Wire US)
A=2(P2)ρlPline(Vm2)
​Go Line Losses (DC Two-Wire US)
Pline=2(P2)ρl(Vm2)A

How to Evaluate Volume of Conductor Material (DC Two-Wire US)?

Volume of Conductor Material (DC Two-Wire US) evaluator uses Volume Of Conductor = 4*(Power Transmitted^2)*Resistivity*(Length of Wire DC^2)/(Line Losses*(Maximum Voltage^2)) to evaluate the Volume Of Conductor, The Volume of Conductor Material (DC Two-Wire US) formula is defined as the 3-dimensional space enclosed by a conductor material of a DC Two-Wire underground system. Volume Of Conductor is denoted by V symbol.

How to evaluate Volume of Conductor Material (DC Two-Wire US) using this online evaluator? To use this online evaluator for Volume of Conductor Material (DC Two-Wire US), enter Power Transmitted (P), Resistivity (ρ), Length of Wire DC (l), Line Losses (Pline) & Maximum Voltage (Vm) and hit the calculate button.

FAQs on Volume of Conductor Material (DC Two-Wire US)

What is the formula to find Volume of Conductor Material (DC Two-Wire US)?
The formula of Volume of Conductor Material (DC Two-Wire US) is expressed as Volume Of Conductor = 4*(Power Transmitted^2)*Resistivity*(Length of Wire DC^2)/(Line Losses*(Maximum Voltage^2)). Here is an example- 0.029013 = 4*(300^2)*1.7E-05*(3.2^2)/(0.6*(60^2)).
How to calculate Volume of Conductor Material (DC Two-Wire US)?
With Power Transmitted (P), Resistivity (ρ), Length of Wire DC (l), Line Losses (Pline) & Maximum Voltage (Vm) we can find Volume of Conductor Material (DC Two-Wire US) using the formula - Volume Of Conductor = 4*(Power Transmitted^2)*Resistivity*(Length of Wire DC^2)/(Line Losses*(Maximum Voltage^2)).
What are the other ways to Calculate Volume Of Conductor?
Here are the different ways to Calculate Volume Of Conductor-
  • Volume Of Conductor=Area of underground dc wire*Length of Wire DC*2OpenImg
  • Volume Of Conductor=4*Resistivity*(Length of Wire DC^2)*(Current underground DC^2)/Line LossesOpenImg
  • Volume Of Conductor=(4*(Power Transmitted^2)*Resistance underground DC*Area of underground dc wire*Length of Wire DC)/(Line Losses*(Maximum Voltage^2))OpenImg
Can the Volume of Conductor Material (DC Two-Wire US) be negative?
Yes, the Volume of Conductor Material (DC Two-Wire US), measured in Volume can be negative.
Which unit is used to measure Volume of Conductor Material (DC Two-Wire US)?
Volume of Conductor Material (DC Two-Wire US) is usually measured using the Cubic Meter[m³] for Volume. Cubic Centimeter[m³], Cubic Millimeter[m³], Liter[m³] are the few other units in which Volume of Conductor Material (DC Two-Wire US) can be measured.
Copied!