Volume of Conductor is the total volume of the material used to make the conductor of an overhead ac line. Check FAQs
V=2AL
V - Volume of Conductor?A - Area of Overhead AC Wire?L - Length of Overhead AC Wire?

Volume of Conductor Material(Single-Phase Two-Wire OS) Example

With values
With units
Only example

Here is how the Volume of Conductor Material(Single-Phase Two-Wire OS) equation looks like with Values.

Here is how the Volume of Conductor Material(Single-Phase Two-Wire OS) equation looks like with Units.

Here is how the Volume of Conductor Material(Single-Phase Two-Wire OS) equation looks like.

16.7954Edit=20.79Edit10.63Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Volume of Conductor Material(Single-Phase Two-Wire OS)

Volume of Conductor Material(Single-Phase Two-Wire OS) Solution

Follow our step by step solution on how to calculate Volume of Conductor Material(Single-Phase Two-Wire OS)?

FIRST Step Consider the formula
V=2AL
Next Step Substitute values of Variables
V=20.7910.63m
Next Step Prepare to Evaluate
V=20.7910.63
LAST Step Evaluate
V=16.7954

Volume of Conductor Material(Single-Phase Two-Wire OS) Formula Elements

Variables
Volume of Conductor
Volume of Conductor is the total volume of the material used to make the conductor of an overhead ac line.
Symbol: V
Measurement: VolumeUnit:
Note: Value can be positive or negative.
Area of Overhead AC Wire
Area of Overhead AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Length of Overhead AC Wire
Length of Overhead AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other Formulas to find Volume of Conductor

​Go Volume of Conductor Material using Line Losses (Single-Phase Two-Wire OS)
V=8ρ(PL)2Ploss(Vmcos(Φ))2
​Go Volume of Conductor Material using Load Current (Single-Phase Two-Wire OS)
V=4(I2)ρ(L2)Ploss

Other formulas in Wire Parameters category

​Go Line Losses(Single-Phase Two-Wire OS)
Ploss=(2)((I)2)R
​Go Area of X-Section(Single-Phase Two-Wire OS)
A=4(P2)ρL((cos(Φ))2)Ploss(Vac2)
​Go Constant(Single-Phase Two-Wire OS)
K=4(P2)ρLPloss(Vac2)
​Go Length of Wire using Area of X-Section(Single-Phase Two-Wire OS)
L=AVm2Plosscos(Φ)24ρ(P2)

How to Evaluate Volume of Conductor Material(Single-Phase Two-Wire OS)?

Volume of Conductor Material(Single-Phase Two-Wire OS) evaluator uses Volume of Conductor = 2*Area of Overhead AC Wire*Length of Overhead AC Wire to evaluate the Volume of Conductor, The Volume of Conductor Material(single-Phase two-Wire OS) formula is defined as the 3-dimensional space enclosed by a conductor material of a single-phase two-wire overhead system. Volume of Conductor is denoted by V symbol.

How to evaluate Volume of Conductor Material(Single-Phase Two-Wire OS) using this online evaluator? To use this online evaluator for Volume of Conductor Material(Single-Phase Two-Wire OS), enter Area of Overhead AC Wire (A) & Length of Overhead AC Wire (L) and hit the calculate button.

FAQs on Volume of Conductor Material(Single-Phase Two-Wire OS)

What is the formula to find Volume of Conductor Material(Single-Phase Two-Wire OS)?
The formula of Volume of Conductor Material(Single-Phase Two-Wire OS) is expressed as Volume of Conductor = 2*Area of Overhead AC Wire*Length of Overhead AC Wire. Here is an example- 16.7954 = 2*0.79*10.63.
How to calculate Volume of Conductor Material(Single-Phase Two-Wire OS)?
With Area of Overhead AC Wire (A) & Length of Overhead AC Wire (L) we can find Volume of Conductor Material(Single-Phase Two-Wire OS) using the formula - Volume of Conductor = 2*Area of Overhead AC Wire*Length of Overhead AC Wire.
What are the other ways to Calculate Volume of Conductor?
Here are the different ways to Calculate Volume of Conductor-
  • Volume of Conductor=(8*Resistivity*(Power Transmitted*Length of Overhead AC Wire)^2)/(Line Losses*(Maximum Voltage Overhead AC*cos(Phase Difference))^2)OpenImg
  • Volume of Conductor=(4*(Current Overhead AC^2)*Resistivity*(Length of Overhead AC Wire^2))/(Line Losses)OpenImg
Can the Volume of Conductor Material(Single-Phase Two-Wire OS) be negative?
Yes, the Volume of Conductor Material(Single-Phase Two-Wire OS), measured in Volume can be negative.
Which unit is used to measure Volume of Conductor Material(Single-Phase Two-Wire OS)?
Volume of Conductor Material(Single-Phase Two-Wire OS) is usually measured using the Cubic Meter[m³] for Volume. Cubic Centimeter[m³], Cubic Millimeter[m³], Liter[m³] are the few other units in which Volume of Conductor Material(Single-Phase Two-Wire OS) can be measured.
Copied!