Volume of Air Passed through Specimen Formula

Fx Copy
LaTeX Copy
Volume of Air Flow Through Specimen is the amount of air which passes through the specimen during testing. Check FAQs
V=PNρAtpHsp
V - Volume of Air Flow Through Specimen?PN - Permeability Number?ρ - Air Pressure on Wall?A - Cross-Sectional Area of Specimen?tp - Time?Hsp - Specimen Height?

Volume of Air Passed through Specimen Example

With values
With units
Only example

Here is how the Volume of Air Passed through Specimen equation looks like with Values.

Here is how the Volume of Air Passed through Specimen equation looks like with Units.

Here is how the Volume of Air Passed through Specimen equation looks like.

0.002Edit=4.36Edit0.0385Edit0.002Edit3Edit5Edit
You are here -
HomeIcon Home » Category Engineering » Category Production Engineering » Category Casting (Foundry) » fx Volume of Air Passed through Specimen

Volume of Air Passed through Specimen Solution

Follow our step by step solution on how to calculate Volume of Air Passed through Specimen?

FIRST Step Consider the formula
V=PNρAtpHsp
Next Step Substitute values of Variables
V=4.36H/m0.0385kgf/m²0.0023s5m
Next Step Convert Units
V=4.36H/m0.3776Pa0.0023s5m
Next Step Prepare to Evaluate
V=4.360.37760.00235
Next Step Evaluate
V=0.00200204065995766
LAST Step Rounding Answer
V=0.002

Volume of Air Passed through Specimen Formula Elements

Variables
Volume of Air Flow Through Specimen
Volume of Air Flow Through Specimen is the amount of air which passes through the specimen during testing.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Permeability Number
Permeability Number is the rate of flow of air passing through a standard specimen under a standard pressure.
Symbol: PN
Measurement: Magnetic PermeabilityUnit: H/m
Note: Value should be greater than 0.
Air Pressure on Wall
Air Pressure on Wall is the pressure exerted by air on the walls in which it is confined.
Symbol: ρ
Measurement: PressureUnit: kgf/m²
Note: Value should be greater than 0.
Cross-Sectional Area of Specimen
Cross-Sectional Area of Specimen is the measure of the surface area perpendicular to the direction of an applied force or load, often used in materials testing to calculate stress and strain.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Time
Time is various stages and durations throughout the casting process.
Symbol: tp
Measurement: TimeUnit: s
Note: Value should be greater than 0.
Specimen Height
Specimen Height is the vertical dimension of a sample or test piece extracted from a casting.
Symbol: Hsp
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other formulas in Permeability Number category

​Go Air Pressure during Testing
ρ=VHspPNAtp
​Go Cross-Sectional Area of Specimen
A=VHspPNρtp
​Go Time Taken during Testing
tp=VHspPNρA
​Go Permeability Number or Standard Specimen
PN=501.28pctp

How to Evaluate Volume of Air Passed through Specimen?

Volume of Air Passed through Specimen evaluator uses Volume of Air Flow Through Specimen = (Permeability Number*Air Pressure on Wall*Cross-Sectional Area of Specimen*Time)/Specimen Height to evaluate the Volume of Air Flow Through Specimen, Volume of air passed through specimen is The measure of the amount of air that flows through a specimen, typically used in permeability testing to evaluate the ability of the specimen to allow air or other gases to pass through it. Volume of Air Flow Through Specimen is denoted by V symbol.

How to evaluate Volume of Air Passed through Specimen using this online evaluator? To use this online evaluator for Volume of Air Passed through Specimen, enter Permeability Number (PN), Air Pressure on Wall (ρ), Cross-Sectional Area of Specimen (A), Time (tp) & Specimen Height (Hsp) and hit the calculate button.

FAQs on Volume of Air Passed through Specimen

What is the formula to find Volume of Air Passed through Specimen?
The formula of Volume of Air Passed through Specimen is expressed as Volume of Air Flow Through Specimen = (Permeability Number*Air Pressure on Wall*Cross-Sectional Area of Specimen*Time)/Specimen Height. Here is an example- 0.002002 = (4.36*0.377556024999973*0.002027*3)/5.
How to calculate Volume of Air Passed through Specimen?
With Permeability Number (PN), Air Pressure on Wall (ρ), Cross-Sectional Area of Specimen (A), Time (tp) & Specimen Height (Hsp) we can find Volume of Air Passed through Specimen using the formula - Volume of Air Flow Through Specimen = (Permeability Number*Air Pressure on Wall*Cross-Sectional Area of Specimen*Time)/Specimen Height.
Can the Volume of Air Passed through Specimen be negative?
No, the Volume of Air Passed through Specimen, measured in Volume cannot be negative.
Which unit is used to measure Volume of Air Passed through Specimen?
Volume of Air Passed through Specimen is usually measured using the Cubic Meter[m³] for Volume. Cubic Centimeter[m³], Cubic Millimeter[m³], Liter[m³] are the few other units in which Volume of Air Passed through Specimen can be measured.
Copied!