Voltage Sensitivity is defined as the deflection produced in the galvanometer when a unit voltage is applied across two terminals. Check FAQs
Sv=θdV
Sv - Voltage Sensitivity?θd - Deflection Angle?V - Voltage across Galvanometer?

Voltage Sensitivity of Galvanometer Example

With values
With units
Only example

Here is how the Voltage Sensitivity of Galvanometer equation looks like with Values.

Here is how the Voltage Sensitivity of Galvanometer equation looks like with Units.

Here is how the Voltage Sensitivity of Galvanometer equation looks like.

0.1047Edit=1.57Edit15Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics and Instrumentation » Category Measuring Instrument Circuits » fx Voltage Sensitivity of Galvanometer

Voltage Sensitivity of Galvanometer Solution

Follow our step by step solution on how to calculate Voltage Sensitivity of Galvanometer?

FIRST Step Consider the formula
Sv=θdV
Next Step Substitute values of Variables
Sv=1.57rad15V
Next Step Prepare to Evaluate
Sv=1.5715
Next Step Evaluate
Sv=0.104666666666667
LAST Step Rounding Answer
Sv=0.1047

Voltage Sensitivity of Galvanometer Formula Elements

Variables
Voltage Sensitivity
Voltage Sensitivity is defined as the deflection produced in the galvanometer when a unit voltage is applied across two terminals.
Symbol: Sv
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Deflection Angle
Deflection Angle is the value indicated on a scale by a pointer that is connected to the suspension wire.
Symbol: θd
Measurement: AngleUnit: rad
Note: Value should be greater than 0.
Voltage across Galvanometer
Voltage across Galvanometer refers to the potential drop between the ends of the galvanometer that occurs when a current flows through it.
Symbol: V
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.

Other formulas in Galvanometer category

​Go EMF across Galvanometer
V=R(I1-I2)
​Go Instantaneous Deflecting Torque
Ti=RK(I12-I22)
​Go Average Current through Galvanometer
I=2NΦtR
​Go Throw of Galvanometer
θ=SgQ

How to Evaluate Voltage Sensitivity of Galvanometer?

Voltage Sensitivity of Galvanometer evaluator uses Voltage Sensitivity = Deflection Angle/Voltage across Galvanometer to evaluate the Voltage Sensitivity, The Voltage Sensitivity of Galvanometer formula is defined as the Voltage Sensitivity of a galvanometer is defined as the deflection produced in the galvanometer when a unit voltage is applied across two terminals. Voltage Sensitivity is denoted by Sv symbol.

How to evaluate Voltage Sensitivity of Galvanometer using this online evaluator? To use this online evaluator for Voltage Sensitivity of Galvanometer, enter Deflection Angle d) & Voltage across Galvanometer (V) and hit the calculate button.

FAQs on Voltage Sensitivity of Galvanometer

What is the formula to find Voltage Sensitivity of Galvanometer?
The formula of Voltage Sensitivity of Galvanometer is expressed as Voltage Sensitivity = Deflection Angle/Voltage across Galvanometer. Here is an example- 0.104667 = 1.57/15.
How to calculate Voltage Sensitivity of Galvanometer?
With Deflection Angle d) & Voltage across Galvanometer (V) we can find Voltage Sensitivity of Galvanometer using the formula - Voltage Sensitivity = Deflection Angle/Voltage across Galvanometer.