The Percentage Regulation of Transformer is the percentage change in the output voltage from no-load to full-load. Check FAQs
%=(I2R2cos(φ2)V2)100
% - Percentage Regulation of Transformer?I2 - Secondary Current?R2 - Resistance of Secondary?φ2 - Secondary Power Factor Angle?V2 - Secondary Voltage?

Voltage Regulation at Unity PF Example

With values
With units
Only example

Here is how the Voltage Regulation at Unity PF equation looks like with Values.

Here is how the Voltage Regulation at Unity PF equation looks like with Units.

Here is how the Voltage Regulation at Unity PF equation looks like.

81.7763Edit=(10.5Edit25.9Editcos(30Edit)288Edit)100
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Machine » fx Voltage Regulation at Unity PF

Voltage Regulation at Unity PF Solution

Follow our step by step solution on how to calculate Voltage Regulation at Unity PF?

FIRST Step Consider the formula
%=(I2R2cos(φ2)V2)100
Next Step Substitute values of Variables
%=(10.5A25.9Ωcos(30°)288V)100
Next Step Convert Units
%=(10.5A25.9Ωcos(0.5236rad)288V)100
Next Step Prepare to Evaluate
%=(10.525.9cos(0.5236)288)100
Next Step Evaluate
%=81.7762529719368
LAST Step Rounding Answer
%=81.7763

Voltage Regulation at Unity PF Formula Elements

Variables
Functions
Percentage Regulation of Transformer
The Percentage Regulation of Transformer is the percentage change in the output voltage from no-load to full-load.
Symbol: %
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Secondary Current
Secondary Current is the current which is flows in the secondary winding of transformer.
Symbol: I2
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Resistance of Secondary
Resistance of Secondary Winding is the resistance of secondary winding.
Symbol: R2
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Secondary Power Factor Angle
Secondary Power Factor Angle is the angle between secondary current and voltage. Power factor is defined as the cosine of the angle between voltage and current.
Symbol: φ2
Measurement: AngleUnit: °
Note: Value should be between -360 to 360.
Secondary Voltage
Secondary Voltage is defined as the voltage on the secondary side of a transformer or the side at which load is connected.
Symbol: V2
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)

Other Formulas to find Percentage Regulation of Transformer

​Go Percentage Regulation of Transformer
%=(Vno-load-Vfull-loadVno-load)100
​Go Voltage Regulation at Lagging PF
%=(I2R2cos(φ2)+I2X2sin(φ2)V2)100
​Go Voltage Regulation at Leading PF
%=(I2R2cos(φ2)-I2X2sin(φ2)V2)100

Other formulas in Transformer Circuit category

​Go Percentage All Day Efficiency of Transformer
all day=(EoutEin)100
​Go Utilisation Factor of Transformer Core
UF=AnetAtotal

How to Evaluate Voltage Regulation at Unity PF?

Voltage Regulation at Unity PF evaluator uses Percentage Regulation of Transformer = ((Secondary Current*Resistance of Secondary*cos(Secondary Power Factor Angle))/Secondary Voltage)*100 to evaluate the Percentage Regulation of Transformer, Voltage Regulation at Unity PF is a measure of change in the voltage magnitude between the sending and receiving end of a component. It is commonly used in power engineering to describe the percentage voltage difference between no load and full load voltages distribution lines, transmission lines, and transformers. Percentage Regulation of Transformer is denoted by % symbol.

How to evaluate Voltage Regulation at Unity PF using this online evaluator? To use this online evaluator for Voltage Regulation at Unity PF, enter Secondary Current (I2), Resistance of Secondary (R2), Secondary Power Factor Angle 2) & Secondary Voltage (V2) and hit the calculate button.

FAQs on Voltage Regulation at Unity PF

What is the formula to find Voltage Regulation at Unity PF?
The formula of Voltage Regulation at Unity PF is expressed as Percentage Regulation of Transformer = ((Secondary Current*Resistance of Secondary*cos(Secondary Power Factor Angle))/Secondary Voltage)*100. Here is an example- 81.77625 = ((10.5*25.9*cos(0.5235987755982))/288)*100.
How to calculate Voltage Regulation at Unity PF?
With Secondary Current (I2), Resistance of Secondary (R2), Secondary Power Factor Angle 2) & Secondary Voltage (V2) we can find Voltage Regulation at Unity PF using the formula - Percentage Regulation of Transformer = ((Secondary Current*Resistance of Secondary*cos(Secondary Power Factor Angle))/Secondary Voltage)*100. This formula also uses Cosine (cos) function(s).
What are the other ways to Calculate Percentage Regulation of Transformer?
Here are the different ways to Calculate Percentage Regulation of Transformer-
  • Percentage Regulation of Transformer=((No Load Terminal Voltage-Full Load Terminal Voltage)/No Load Terminal Voltage)*100OpenImg
  • Percentage Regulation of Transformer=((Secondary Current*Resistance of Secondary*cos(Secondary Power Factor Angle)+Secondary Current*Secondary Reactance*sin(Secondary Power Factor Angle))/Secondary Voltage)*100OpenImg
  • Percentage Regulation of Transformer=((Secondary Current*Resistance of Secondary*cos(Secondary Power Factor Angle)-Secondary Current*Secondary Reactance*sin(Secondary Power Factor Angle))/Secondary Voltage)*100OpenImg