Viscosity Correction Factor for Shell and Tube Heat Exchanger Formula

Fx Copy
LaTeX Copy
Viscosity Correction Factor is ratio of fluid viscosity at mean temperature to fluid viscosity at the wall temperature. Check FAQs
μCorrection=(μfluidμWall)0.14
μCorrection - Viscosity Correction Factor?μfluid - Fluid Viscosity at Bulk Temperature?μWall - Fluid Viscosity at Wall Temperature?

Viscosity Correction Factor for Shell and Tube Heat Exchanger Example

With values
With units
Only example

Here is how the Viscosity Correction Factor for Shell and Tube Heat Exchanger equation looks like with Values.

Here is how the Viscosity Correction Factor for Shell and Tube Heat Exchanger equation looks like with Units.

Here is how the Viscosity Correction Factor for Shell and Tube Heat Exchanger equation looks like.

0.9999Edit=(1.005Edit1.006Edit)0.14
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Process Equipment Design » fx Viscosity Correction Factor for Shell and Tube Heat Exchanger

Viscosity Correction Factor for Shell and Tube Heat Exchanger Solution

Follow our step by step solution on how to calculate Viscosity Correction Factor for Shell and Tube Heat Exchanger?

FIRST Step Consider the formula
μCorrection=(μfluidμWall)0.14
Next Step Substitute values of Variables
μCorrection=(1.005Pa*s1.006Pa*s)0.14
Next Step Prepare to Evaluate
μCorrection=(1.0051.006)0.14
Next Step Evaluate
μCorrection=0.999860775469323
LAST Step Rounding Answer
μCorrection=0.9999

Viscosity Correction Factor for Shell and Tube Heat Exchanger Formula Elements

Variables
Viscosity Correction Factor
Viscosity Correction Factor is ratio of fluid viscosity at mean temperature to fluid viscosity at the wall temperature.
Symbol: μCorrection
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Fluid Viscosity at Bulk Temperature
Fluid viscosity at Bulk Temperature is a fundamental property of fluids that characterizes their resistance to flow. It is defined at the bulk temperature of the fluid.
Symbol: μfluid
Measurement: Dynamic ViscosityUnit: Pa*s
Note: Value should be greater than 0.
Fluid Viscosity at Wall Temperature
Fluid Viscosity at Wall Temperature is defined at the temperature of the wall of pipe or surface at which the fluid is in contact with it.
Symbol: μWall
Measurement: Dynamic ViscosityUnit: Pa*s
Note: Value should be greater than 0.

Other formulas in Basic Formulas of Heat Exchanger Designs category

​Go Equivalent Diameter for Square Pitch in Heat Exchanger
De=(1.27DOuter)((PTube2)-0.785(DOuter2))
​Go Equivalent Diameter for Triangular Pitch in Heat Exchanger
De=(1.10DOuter)((PTube2)-0.917(DOuter2))
​Go Number of Baffles in Shell and Tube Heat Exchanger
NBaffles=(LTubeLBaffle)-1
​Go Number of Tubes in Center Row Given Bundle Diameter and Tube Pitch
Nr=DBPTube

How to Evaluate Viscosity Correction Factor for Shell and Tube Heat Exchanger?

Viscosity Correction Factor for Shell and Tube Heat Exchanger evaluator uses Viscosity Correction Factor = (Fluid Viscosity at Bulk Temperature/Fluid Viscosity at Wall Temperature)^0.14 to evaluate the Viscosity Correction Factor, The Viscosity Correction Factor For Shell and Tube Heat Exchanger formula is defined as the ratio of viscosity of fluid at bulk temperature by viscosity of fluid at the wall temperature in pipe flow. Viscosity being function of temperature, the correction factor becomes important parameter. Viscosity Correction Factor is denoted by μCorrection symbol.

How to evaluate Viscosity Correction Factor for Shell and Tube Heat Exchanger using this online evaluator? To use this online evaluator for Viscosity Correction Factor for Shell and Tube Heat Exchanger, enter Fluid Viscosity at Bulk Temperature fluid) & Fluid Viscosity at Wall Temperature Wall) and hit the calculate button.

FAQs on Viscosity Correction Factor for Shell and Tube Heat Exchanger

What is the formula to find Viscosity Correction Factor for Shell and Tube Heat Exchanger?
The formula of Viscosity Correction Factor for Shell and Tube Heat Exchanger is expressed as Viscosity Correction Factor = (Fluid Viscosity at Bulk Temperature/Fluid Viscosity at Wall Temperature)^0.14. Here is an example- 0.999861 = (1.005/1.006)^0.14.
How to calculate Viscosity Correction Factor for Shell and Tube Heat Exchanger?
With Fluid Viscosity at Bulk Temperature fluid) & Fluid Viscosity at Wall Temperature Wall) we can find Viscosity Correction Factor for Shell and Tube Heat Exchanger using the formula - Viscosity Correction Factor = (Fluid Viscosity at Bulk Temperature/Fluid Viscosity at Wall Temperature)^0.14.
Copied!