Viscosity Calculation using Chapman-Rubesin Factor Formula

Fx Copy
LaTeX Copy
The Kinematic Viscosity is a measure of a fluid's resistance to flow under the influence of gravity, reflecting its internal friction and temperature dependence. Check FAQs
ν=Cρeμeρ
ν - Kinematic Viscosity?C - Chapman–Rubesin factor?ρe - Static Density?μe - Static Viscosity?ρ - Density?

Viscosity Calculation using Chapman-Rubesin Factor Example

With values
With units
Only example

Here is how the Viscosity Calculation using Chapman-Rubesin Factor equation looks like with Values.

Here is how the Viscosity Calculation using Chapman-Rubesin Factor equation looks like with Units.

Here is how the Viscosity Calculation using Chapman-Rubesin Factor equation looks like.

7.25Edit=0.75Edit98.3Edit0.098Edit997Edit
You are here -
HomeIcon Home » Category Engineering » Category Mechanical » Category Fluid Mechanics » fx Viscosity Calculation using Chapman-Rubesin Factor

Viscosity Calculation using Chapman-Rubesin Factor Solution

Follow our step by step solution on how to calculate Viscosity Calculation using Chapman-Rubesin Factor?

FIRST Step Consider the formula
ν=Cρeμeρ
Next Step Substitute values of Variables
ν=0.7598.3kg/m³0.098P997kg/m³
Next Step Convert Units
ν=0.7598.3kg/m³0.0098Pa*s997kg/m³
Next Step Prepare to Evaluate
ν=0.7598.30.0098997
Next Step Evaluate
ν=0.000724997008525577m²/s
Next Step Convert to Output's Unit
ν=7.24997008525577St
LAST Step Rounding Answer
ν=7.25St

Viscosity Calculation using Chapman-Rubesin Factor Formula Elements

Variables
Kinematic Viscosity
The Kinematic Viscosity is a measure of a fluid's resistance to flow under the influence of gravity, reflecting its internal friction and temperature dependence.
Symbol: ν
Measurement: Kinematic ViscosityUnit: St
Note: Value should be greater than 0.
Chapman–Rubesin factor
The Chapman–Rubesin factor is a dimensionless quantity used in fluid mechanics to characterize the effects of viscosity in hypersonic flow conditions.
Symbol: C
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Static Density
The Static Density is the mass per unit volume of a fluid at rest, crucial for understanding fluid behavior in various engineering applications, especially in hypersonic flow dynamics.
Symbol: ρe
Measurement: DensityUnit: kg/m³
Note: Value should be greater than 0.
Static Viscosity
The Static Viscosity is a measure of a fluid's resistance to flow under an applied stress, crucial for understanding fluid behavior in various mechanical and thermal applications.
Symbol: μe
Measurement: Dynamic ViscosityUnit: P
Note: Value should be greater than 0.
Density
The Density is the mass per unit volume of a substance, which influences fluid behavior and thermal properties in hypersonic flow and aero thermal dynamics.
Symbol: ρ
Measurement: DensityUnit: kg/m³
Note: Value should be greater than 0.

Other formulas in Aero Thermal Dynamics category

​Go Non Dimensional Internal Energy Parameter
e'=UCpT
​Go Non Dimensional Internal Energy Parameter using Wall-to-Freestream Temperature Ratio
e'=TwT
​Go Wall Temperature Calculation using Internal Energy Change
Tw=e'T
​Go Aerodynamic Heating to Surface
qw=ρeueSt(haw-hw)

How to Evaluate Viscosity Calculation using Chapman-Rubesin Factor?

Viscosity Calculation using Chapman-Rubesin Factor evaluator uses Kinematic Viscosity = Chapman–Rubesin factor*Static Density*Static Viscosity/(Density) to evaluate the Kinematic Viscosity, Viscosity Calculation using Chapman-Rubesin Factor formula is a measure of the dynamic viscosity of a fluid, which is the measure of its resistance to shear stress, and is an important property in the study of viscous flow fundamentals. Kinematic Viscosity is denoted by ν symbol.

How to evaluate Viscosity Calculation using Chapman-Rubesin Factor using this online evaluator? To use this online evaluator for Viscosity Calculation using Chapman-Rubesin Factor, enter Chapman–Rubesin factor (C), Static Density e), Static Viscosity e) & Density (ρ) and hit the calculate button.

FAQs on Viscosity Calculation using Chapman-Rubesin Factor

What is the formula to find Viscosity Calculation using Chapman-Rubesin Factor?
The formula of Viscosity Calculation using Chapman-Rubesin Factor is expressed as Kinematic Viscosity = Chapman–Rubesin factor*Static Density*Static Viscosity/(Density). Here is an example- 8.3E+6 = 0.75*98.3*0.0098043/(997).
How to calculate Viscosity Calculation using Chapman-Rubesin Factor?
With Chapman–Rubesin factor (C), Static Density e), Static Viscosity e) & Density (ρ) we can find Viscosity Calculation using Chapman-Rubesin Factor using the formula - Kinematic Viscosity = Chapman–Rubesin factor*Static Density*Static Viscosity/(Density).
Can the Viscosity Calculation using Chapman-Rubesin Factor be negative?
No, the Viscosity Calculation using Chapman-Rubesin Factor, measured in Kinematic Viscosity cannot be negative.
Which unit is used to measure Viscosity Calculation using Chapman-Rubesin Factor?
Viscosity Calculation using Chapman-Rubesin Factor is usually measured using the Stokes[St] for Kinematic Viscosity. Square Meter per Second[St], Square Meter per Hour[St], Square Centimeter per Second[St] are the few other units in which Viscosity Calculation using Chapman-Rubesin Factor can be measured.
Copied!