Viscosity Calculation using Chapman-Rubesin Factor Formula

Fx Copy
LaTeX Copy
The Kinematic Viscosity is a measure of a fluid's resistance to flow under the influence of gravity, reflecting its internal friction and temperature dependence. Check FAQs
ν=Cρeμeρ
ν - Kinematic Viscosity?C - Chapman–Rubesin factor?ρe - Static Density?μe - Static Viscosity?ρ - Density?

Viscosity Calculation using Chapman-Rubesin Factor Example

With values
With units
Only example

Here is how the Viscosity Calculation using Chapman-Rubesin Factor equation looks like with Values.

Here is how the Viscosity Calculation using Chapman-Rubesin Factor equation looks like with Units.

Here is how the Viscosity Calculation using Chapman-Rubesin Factor equation looks like.

828.2046Edit=0.75Edit98.3Edit11.2Edit997Edit
You are here -
HomeIcon Home » Category Engineering » Category Mechanical » Category Fluid Mechanics » fx Viscosity Calculation using Chapman-Rubesin Factor

Viscosity Calculation using Chapman-Rubesin Factor Solution

Follow our step by step solution on how to calculate Viscosity Calculation using Chapman-Rubesin Factor?

FIRST Step Consider the formula
ν=Cρeμeρ
Next Step Substitute values of Variables
ν=0.7598.3kg/m³11.2P997kg/m³
Next Step Convert Units
ν=0.7598.3kg/m³1.12Pa*s997kg/m³
Next Step Prepare to Evaluate
ν=0.7598.31.12997
Next Step Evaluate
ν=0.0828204613841525m²/s
Next Step Convert to Output's Unit
ν=828.204613841525St
LAST Step Rounding Answer
ν=828.2046St

Viscosity Calculation using Chapman-Rubesin Factor Formula Elements

Variables
Kinematic Viscosity
The Kinematic Viscosity is a measure of a fluid's resistance to flow under the influence of gravity, reflecting its internal friction and temperature dependence.
Symbol: ν
Measurement: Kinematic ViscosityUnit: St
Note: Value should be greater than 0.
Chapman–Rubesin factor
The Chapman–Rubesin factor is a dimensionless quantity used in fluid mechanics to characterize the effects of viscosity in hypersonic flow conditions.
Symbol: C
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Static Density
The Static Density is the mass per unit volume of a fluid at rest, crucial for understanding fluid behavior in various engineering applications, especially in hypersonic flow dynamics.
Symbol: ρe
Measurement: DensityUnit: kg/m³
Note: Value should be greater than 0.
Static Viscosity
Static viscosity, is the viscosity of continuous flow, viscosity measures the ratio of the viscous force to the inertial force on the fluid.
Symbol: μe
Measurement: Dynamic ViscosityUnit: P
Note: Value should be greater than 0.
Density
The Density is the mass per unit volume of a substance, which influences fluid behavior and thermal properties in hypersonic flow and aero thermal dynamics.
Symbol: ρ
Measurement: DensityUnit: kg/m³
Note: Value should be greater than 0.

Other formulas in Aero Thermal Dynamics category

​Go Non Dimensional Internal Energy Parameter
e'=UcT
​Go Non Dimensional Internal Energy Parameter using Wall-to-Freestream Temperature Ratio
e'=TwT
​Go Wall Temperature Calculation using Internal Energy Change
Tw=e'T
​Go Aerodynamic Heating to Surface
qw=ρeueSt(haw-hw)

How to Evaluate Viscosity Calculation using Chapman-Rubesin Factor?

Viscosity Calculation using Chapman-Rubesin Factor evaluator uses Kinematic Viscosity = Chapman–Rubesin factor*Static Density*Static Viscosity/(Density) to evaluate the Kinematic Viscosity, Viscosity Calculation using Chapman-Rubesin Factor formula is a measure of the dynamic viscosity of a fluid, which is the measure of its resistance to shear stress, and is an important property in the study of viscous flow fundamentals. Kinematic Viscosity is denoted by ν symbol.

How to evaluate Viscosity Calculation using Chapman-Rubesin Factor using this online evaluator? To use this online evaluator for Viscosity Calculation using Chapman-Rubesin Factor, enter Chapman–Rubesin factor (C), Static Density e), Static Viscosity (μe) & Density (ρ) and hit the calculate button.

FAQs on Viscosity Calculation using Chapman-Rubesin Factor

What is the formula to find Viscosity Calculation using Chapman-Rubesin Factor?
The formula of Viscosity Calculation using Chapman-Rubesin Factor is expressed as Kinematic Viscosity = Chapman–Rubesin factor*Static Density*Static Viscosity/(Density). Here is an example- 8.3E+6 = 0.75*98.3*0.0098043/(997).
How to calculate Viscosity Calculation using Chapman-Rubesin Factor?
With Chapman–Rubesin factor (C), Static Density e), Static Viscosity (μe) & Density (ρ) we can find Viscosity Calculation using Chapman-Rubesin Factor using the formula - Kinematic Viscosity = Chapman–Rubesin factor*Static Density*Static Viscosity/(Density).
Can the Viscosity Calculation using Chapman-Rubesin Factor be negative?
No, the Viscosity Calculation using Chapman-Rubesin Factor, measured in Kinematic Viscosity cannot be negative.
Which unit is used to measure Viscosity Calculation using Chapman-Rubesin Factor?
Viscosity Calculation using Chapman-Rubesin Factor is usually measured using the Stokes[St] for Kinematic Viscosity. Square Meter per Second[St], Square Meter per Hour[St], Square Centimeter per Second[St] are the few other units in which Viscosity Calculation using Chapman-Rubesin Factor can be measured.
Copied!