Fx Copy
LaTeX Copy
The Venturi head refers to the difference between pressure head at inlet and pressure head at the throat. Check FAQs
hventuri=L(𝑤γf-1)
hventuri - Venturi Head?L - Length of Venturi meter?𝑤 - Weight per unit Volume of Manometer Fluid?γf - Specific Weight of Liquid?

Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs Example

With values
With units
Only example

Here is how the Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs equation looks like with Values.

Here is how the Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs equation looks like with Units.

Here is how the Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs equation looks like.

24.1101Edit=3Edit(9888.84Edit9.81Edit-1)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Hydraulics and Waterworks » fx Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs

Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs Solution

Follow our step by step solution on how to calculate Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs?

FIRST Step Consider the formula
hventuri=L(𝑤γf-1)
Next Step Substitute values of Variables
hventuri=3m(9888.84N/m³9.81kN/m³-1)
Next Step Convert Units
hventuri=3m(9888.84N/m³9810N/m³-1)
Next Step Prepare to Evaluate
hventuri=3(9888.849810-1)
Next Step Evaluate
hventuri=0.0241100917431192m
Next Step Convert to Output's Unit
hventuri=24.1100917431192mm
LAST Step Rounding Answer
hventuri=24.1101mm

Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs Formula Elements

Variables
Venturi Head
The Venturi head refers to the difference between pressure head at inlet and pressure head at the throat.
Symbol: hventuri
Measurement: LengthUnit: mm
Note: Value can be positive or negative.
Length of Venturi meter
The Length of Venturi meter refers to the measurement or extent of something from end to end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Weight per unit Volume of Manometer Fluid
The Weight per unit Volume of Manometer Fluid is obtained as the product of the density of manometric fluid and acceleration of gravity g.
Symbol: 𝑤
Measurement: Specific WeightUnit: N/m³
Note: Value should be greater than 0.
Specific Weight of Liquid
The Specific Weight of Liquid refers to the weight per unit volume of that substance.
Symbol: γf
Measurement: Specific WeightUnit: kN/m³
Note: Value should be greater than 0.

Other Formulas to find Venturi Head

​Go Venturi Head given Theoretical Discharge through Pipe
hventuri=((QthAiAf)((Ai)2-(Af)22[g]))2

Other formulas in Venturi Meter category

​Go Theoretical Discharge through Pipe
Qth=AiAf(2[g]hventuri)(Ai)2-(Af)2
​Go Throat Area given Theoretical Discharge
Af=(AiQth)2(Ai22[g]hventuri)+Qth2
​Go Inlet Area given Theoretical Discharge
Ai=(QthAf)2(Qth)2-(Af22[g]hventuri)
​Go Coefficient of Discharge given Discharges
Cd=QactualVtheoritical

How to Evaluate Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs?

Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs evaluator uses Venturi Head = Length of Venturi meter*(Weight per unit Volume of Manometer Fluid/Specific Weight of Liquid-1) to evaluate the Venturi Head, The Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs formula is defined as total head loss while the flow happens in a pipe. Venturi Head is denoted by hventuri symbol.

How to evaluate Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs using this online evaluator? To use this online evaluator for Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs, enter Length of Venturi meter (L), Weight per unit Volume of Manometer Fluid (𝑤) & Specific Weight of Liquid f) and hit the calculate button.

FAQs on Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs

What is the formula to find Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs?
The formula of Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs is expressed as Venturi Head = Length of Venturi meter*(Weight per unit Volume of Manometer Fluid/Specific Weight of Liquid-1). Here is an example- 24110.09 = 3*(9888.84/9810-1).
How to calculate Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs?
With Length of Venturi meter (L), Weight per unit Volume of Manometer Fluid (𝑤) & Specific Weight of Liquid f) we can find Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs using the formula - Venturi Head = Length of Venturi meter*(Weight per unit Volume of Manometer Fluid/Specific Weight of Liquid-1).
What are the other ways to Calculate Venturi Head?
Here are the different ways to Calculate Venturi Head-
  • Venturi Head=((Theoretical Discharge/(Cross Section Area 1*Cross Section Area 2))*(sqrt(((Cross Section Area 1)^2-(Cross Section Area 2)^2)/(2*[g]))))^2OpenImg
Can the Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs be negative?
Yes, the Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs, measured in Length can be negative.
Which unit is used to measure Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs?
Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs is usually measured using the Millimeter[mm] for Length. Meter[mm], Kilometer[mm], Decimeter[mm] are the few other units in which Venturi Head given Difference in Levels of Manometric Liquid in Two Limbs can be measured.
Copied!