Fx Copy
LaTeX Copy
Velocity while Running Full refers to the speed of fluid flow in a pipe when it's completely filled, influenced by pipe slope and roughness. Check FAQs
V=Vs(Nnp)(rpfRrf)23sss
V - Velocity While Running Full?Vs - Velocity in a Partially Running Sewer?N - Roughness Coefficient for Running Full?np - Roughness Coefficient Partially Full?rpf - Hydraulic Mean Depth for Partially Full?Rrf - Hydraulic Mean Depth while Running Full?ss - Bed Slope of Partial Flow?s - Bed Slope of Channel?

Velocity when Running Full using Bed Slope for Partial Flow Example

With values
With units
Only example

Here is how the Velocity when Running Full using Bed Slope for Partial Flow equation looks like with Values.

Here is how the Velocity when Running Full using Bed Slope for Partial Flow equation looks like with Units.

Here is how the Velocity when Running Full using Bed Slope for Partial Flow equation looks like.

5.7637Edit=4.6Edit(0.74Edit0.9Edit)(3.2Edit5.2Edit)230.0018Edit0.001Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Velocity when Running Full using Bed Slope for Partial Flow

Velocity when Running Full using Bed Slope for Partial Flow Solution

Follow our step by step solution on how to calculate Velocity when Running Full using Bed Slope for Partial Flow?

FIRST Step Consider the formula
V=Vs(Nnp)(rpfRrf)23sss
Next Step Substitute values of Variables
V=4.6m/s(0.740.9)(3.2m5.2m)230.00180.001
Next Step Prepare to Evaluate
V=4.6(0.740.9)(3.25.2)230.00180.001
Next Step Evaluate
V=5.76369882284834m/s
LAST Step Rounding Answer
V=5.7637m/s

Velocity when Running Full using Bed Slope for Partial Flow Formula Elements

Variables
Functions
Velocity While Running Full
Velocity while Running Full refers to the speed of fluid flow in a pipe when it's completely filled, influenced by pipe slope and roughness.
Symbol: V
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Velocity in a Partially Running Sewer
Velocity in a Partially Running Sewer is the speed of flow when the sewer isn't fully filled, influenced by depth and slope.
Symbol: Vs
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Roughness Coefficient for Running Full
The Roughness Coefficient for Running Full accounts for uniform surface resistance affecting flow velocity and friction loss.
Symbol: N
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Roughness Coefficient Partially Full
Roughness Coefficient Partially Full means roughness coefficient of pipe while running partially full.
Symbol: np
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Hydraulic Mean Depth for Partially Full
Hydraulic Mean Depth for Partially Full refers to the cross-sectional area of flow divided by the wetted perimeter, adapting to varying water levels.
Symbol: rpf
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Hydraulic Mean Depth while Running Full
Hydraulic Mean Depth while Running Full refers to the ratio of the pipe's full cross-sectional area to its full wetted perimeter.
Symbol: Rrf
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Bed Slope of Partial Flow
Bed Slope of Partial Flow means the slope at which partial flow is occurring.
Symbol: ss
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Bed Slope of Channel
Bed Slope of Channel refers to the gradient or incline of a channel's bed, influencing the velocity and direction of water flow, typically measured as a ratio or percentage.
Symbol: s
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Velocity While Running Full

​Go Velocity of Full Flow given Hydraulic Mean Depth Ratio
V=Vs(Nnp)(R)16
​Go Velocity of Full Flow given Hydraulic Mean Depth for Full Flow
V=Vs(Nnp)(rpfRrf)16

Other formulas in Flow Velocity through Circular Sewer category

​Go Velocity Ratio given Ratio of Bed Slope
νsVratio=(Nnp)(rpfRrf)23S
​Go Self Cleansing Velocity using Ratio of Bed Slope
Vs=V((Nnp)(rpfRrf)23S)

How to Evaluate Velocity when Running Full using Bed Slope for Partial Flow?

Velocity when Running Full using Bed Slope for Partial Flow evaluator uses Velocity While Running Full = Velocity in a Partially Running Sewer/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)*sqrt(Bed Slope of Partial Flow/Bed Slope of Channel)) to evaluate the Velocity While Running Full, The Velocity when Running Full using Bed Slope for Partial Flow is defined as the speed of fluid flow in a pipe when it's completely filled, influenced by pipe slope and roughness. Velocity While Running Full is denoted by V symbol.

How to evaluate Velocity when Running Full using Bed Slope for Partial Flow using this online evaluator? To use this online evaluator for Velocity when Running Full using Bed Slope for Partial Flow, enter Velocity in a Partially Running Sewer (Vs), Roughness Coefficient for Running Full (N), Roughness Coefficient Partially Full (np), Hydraulic Mean Depth for Partially Full (rpf), Hydraulic Mean Depth while Running Full (Rrf), Bed Slope of Partial Flow (ss) & Bed Slope of Channel (s) and hit the calculate button.

FAQs on Velocity when Running Full using Bed Slope for Partial Flow

What is the formula to find Velocity when Running Full using Bed Slope for Partial Flow?
The formula of Velocity when Running Full using Bed Slope for Partial Flow is expressed as Velocity While Running Full = Velocity in a Partially Running Sewer/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)*sqrt(Bed Slope of Partial Flow/Bed Slope of Channel)). Here is an example- 0.172911 = 4.6/((0.74/0.9)*(3.2/5.2)^(2/3)*sqrt(bed_slope_of_partial_flow/0.001)).
How to calculate Velocity when Running Full using Bed Slope for Partial Flow?
With Velocity in a Partially Running Sewer (Vs), Roughness Coefficient for Running Full (N), Roughness Coefficient Partially Full (np), Hydraulic Mean Depth for Partially Full (rpf), Hydraulic Mean Depth while Running Full (Rrf), Bed Slope of Partial Flow (ss) & Bed Slope of Channel (s) we can find Velocity when Running Full using Bed Slope for Partial Flow using the formula - Velocity While Running Full = Velocity in a Partially Running Sewer/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)*sqrt(Bed Slope of Partial Flow/Bed Slope of Channel)). This formula also uses Square Root Function function(s).
What are the other ways to Calculate Velocity While Running Full?
Here are the different ways to Calculate Velocity While Running Full-
  • Velocity While Running Full=Velocity in a Partially Running Sewer/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth Ratio)^(1/6))OpenImg
  • Velocity While Running Full=Velocity in a Partially Running Sewer/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(1/6))OpenImg
  • Velocity While Running Full=Velocity in a Partially Running Sewer/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*(Hydraulic Mean Depth for Partially Full/Hydraulic Mean Depth while Running Full)^(2/3)*sqrt(Bed Slope Ratio))OpenImg
Can the Velocity when Running Full using Bed Slope for Partial Flow be negative?
No, the Velocity when Running Full using Bed Slope for Partial Flow, measured in Speed cannot be negative.
Which unit is used to measure Velocity when Running Full using Bed Slope for Partial Flow?
Velocity when Running Full using Bed Slope for Partial Flow is usually measured using the Meter per Second[m/s] for Speed. Meter per Minute[m/s], Meter per Hour[m/s], Kilometer per Hour[m/s] are the few other units in which Velocity when Running Full using Bed Slope for Partial Flow can be measured.
Copied!