Velocity of water at outlet of draft tube given draft tube efficiency Formula

Fx Copy
LaTeX Copy
Velocity of water at outlet of draft tube is the velocity of water flowing though the outlet of draft tube which is the end with bigger area of cross section. Check FAQs
V2=(V12)(1-ηd)-(hf2[g])
V2 - Velocity of water at outlet of draft tube?V1 - Velocity of water at inlet of draft tube?ηd - Efficiency of Draft Tube?hf - Loss of head in draft tube?[g] - Gravitational acceleration on Earth?

Velocity of water at outlet of draft tube given draft tube efficiency Example

With values
With units
Only example

Here is how the Velocity of water at outlet of draft tube given draft tube efficiency equation looks like with Values.

Here is how the Velocity of water at outlet of draft tube given draft tube efficiency equation looks like with Units.

Here is how the Velocity of water at outlet of draft tube given draft tube efficiency equation looks like.

1.2801Edit=(6Edit2)(1-0.9Edit)-(0.1Edit29.8066)
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Fluid Mechanics » fx Velocity of water at outlet of draft tube given draft tube efficiency

Velocity of water at outlet of draft tube given draft tube efficiency Solution

Follow our step by step solution on how to calculate Velocity of water at outlet of draft tube given draft tube efficiency?

FIRST Step Consider the formula
V2=(V12)(1-ηd)-(hf2[g])
Next Step Substitute values of Variables
V2=(6m/s2)(1-0.9)-(0.1m2[g])
Next Step Substitute values of Constants
V2=(6m/s2)(1-0.9)-(0.1m29.8066m/s²)
Next Step Prepare to Evaluate
V2=(62)(1-0.9)-(0.129.8066)
Next Step Evaluate
V2=1.28010546440518m/s
LAST Step Rounding Answer
V2=1.2801m/s

Velocity of water at outlet of draft tube given draft tube efficiency Formula Elements

Variables
Constants
Functions
Velocity of water at outlet of draft tube
Velocity of water at outlet of draft tube is the velocity of water flowing though the outlet of draft tube which is the end with bigger area of cross section.
Symbol: V2
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Velocity of water at inlet of draft tube
Velocity of water at inlet of draft tube is the velocity of water entering the inlet of draft tube which is the part with smaller area of cross section.
Symbol: V1
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Efficiency of Draft Tube
The Efficiency of Draft Tube is defined as the ratio of the actual conversion of the kinetic head into the pressure head in the draft tube to the kinetic head at the inlet of the draft tube.
Symbol: ηd
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Loss of head in draft tube
Loss of head in draft tube is defined as the difference in head at the start and end of the draft tube.
Symbol: hf
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Gravitational acceleration on Earth
Gravitational acceleration on Earth means that the velocity of an object in free fall will increase by 9.8 m/s2 every second.
Symbol: [g]
Value: 9.80665 m/s²
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other formulas in Draft Tube category

​Go Efficiency of draft tube
ηd=((V122[g])-(V222[g]))-(hf)V122[g]
​Go Head loss in draft tube given efficiency
hf=((V122[g])-(V222[g]))-(ηd(V122[g]))
​Go Velocity of water at inlet of draft tube given draft tube efficiency
V1=(V22)+(hf2[g])1-ηd

How to Evaluate Velocity of water at outlet of draft tube given draft tube efficiency?

Velocity of water at outlet of draft tube given draft tube efficiency evaluator uses Velocity of water at outlet of draft tube = sqrt((Velocity of water at inlet of draft tube^2)*(1-Efficiency of Draft Tube)-(Loss of head in draft tube*2*[g])) to evaluate the Velocity of water at outlet of draft tube, The Velocity of water at outlet of draft tube given draft tube efficiency formula is used to find the speed of the water at the outlet of the draft tube which is the end having a larger cross-section area. Velocity of water at outlet of draft tube is denoted by V2 symbol.

How to evaluate Velocity of water at outlet of draft tube given draft tube efficiency using this online evaluator? To use this online evaluator for Velocity of water at outlet of draft tube given draft tube efficiency, enter Velocity of water at inlet of draft tube (V1), Efficiency of Draft Tube d) & Loss of head in draft tube (hf) and hit the calculate button.

FAQs on Velocity of water at outlet of draft tube given draft tube efficiency

What is the formula to find Velocity of water at outlet of draft tube given draft tube efficiency?
The formula of Velocity of water at outlet of draft tube given draft tube efficiency is expressed as Velocity of water at outlet of draft tube = sqrt((Velocity of water at inlet of draft tube^2)*(1-Efficiency of Draft Tube)-(Loss of head in draft tube*2*[g])). Here is an example- 1.280105 = sqrt((6^2)*(1-0.9)-(0.1*2*[g])).
How to calculate Velocity of water at outlet of draft tube given draft tube efficiency?
With Velocity of water at inlet of draft tube (V1), Efficiency of Draft Tube d) & Loss of head in draft tube (hf) we can find Velocity of water at outlet of draft tube given draft tube efficiency using the formula - Velocity of water at outlet of draft tube = sqrt((Velocity of water at inlet of draft tube^2)*(1-Efficiency of Draft Tube)-(Loss of head in draft tube*2*[g])). This formula also uses Gravitational acceleration on Earth constant(s) and Square Root Function function(s).
Can the Velocity of water at outlet of draft tube given draft tube efficiency be negative?
No, the Velocity of water at outlet of draft tube given draft tube efficiency, measured in Speed cannot be negative.
Which unit is used to measure Velocity of water at outlet of draft tube given draft tube efficiency?
Velocity of water at outlet of draft tube given draft tube efficiency is usually measured using the Meter per Second[m/s] for Speed. Meter per Minute[m/s], Meter per Hour[m/s], Kilometer per Hour[m/s] are the few other units in which Velocity of water at outlet of draft tube given draft tube efficiency can be measured.
Copied!