Fx Copy
LaTeX Copy
Ultimate Shear Connector Stress is the maximum strength in shear. Check FAQs
Sultimate=Pon slabNΦ
Sultimate - Ultimate Shear Connector Stress?Pon slab - Slab Force?N - No of Connector in Bridge?Φ - Reduction Factor?

Ultimate Shear Connector Strength given Number of Connectors in Bridges Example

With values
With units
Only example

Here is how the Ultimate Shear Connector Strength given Number of Connectors in Bridges equation looks like with Values.

Here is how the Ultimate Shear Connector Strength given Number of Connectors in Bridges equation looks like with Units.

Here is how the Ultimate Shear Connector Strength given Number of Connectors in Bridges equation looks like.

19.2157Edit=245Edit15Edit0.85Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Bridge and Suspension Cable » fx Ultimate Shear Connector Strength given Number of Connectors in Bridges

Ultimate Shear Connector Strength given Number of Connectors in Bridges Solution

Follow our step by step solution on how to calculate Ultimate Shear Connector Strength given Number of Connectors in Bridges?

FIRST Step Consider the formula
Sultimate=Pon slabNΦ
Next Step Substitute values of Variables
Sultimate=245kN150.85
Next Step Convert Units
Sultimate=245000N150.85
Next Step Prepare to Evaluate
Sultimate=245000150.85
Next Step Evaluate
Sultimate=19215.6862745098N
Next Step Convert to Output's Unit
Sultimate=19.2156862745098kN
LAST Step Rounding Answer
Sultimate=19.2157kN

Ultimate Shear Connector Strength given Number of Connectors in Bridges Formula Elements

Variables
Ultimate Shear Connector Stress
Ultimate Shear Connector Stress is the maximum strength in shear.
Symbol: Sultimate
Measurement: ForceUnit: kN
Note: Value can be positive or negative.
Slab Force
Slab Force at maximum positive moments.
Symbol: Pon slab
Measurement: ForceUnit: kN
Note: Value can be positive or negative.
No of Connector in Bridge
No of Connector in Bridge is total number of joints.
Symbol: N
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Reduction Factor
Reduction Factor is constant term used as factor for load calculation.
Symbol: Φ
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other Formulas to find Ultimate Shear Connector Stress

​Go Ultimate Shear Connector Strength given Minimum Number of Connectors in Bridges
Sultimate=Pon slab+P3ΦN

Other formulas in Number of Connectors in Bridges category

​Go Number of Connectors in Bridges
N=Pon slabΦSultimate
​Go Force in Slab given Number of Connectors in Bridges
Pon slab=NΦSultimate
​Go Reduction Factor given Number of Connectors in Bridges
Φ=Pon slabNSultimate
​Go Force in Slab given Total Area of Steel Section
Pon slab=Astfy

How to Evaluate Ultimate Shear Connector Strength given Number of Connectors in Bridges?

Ultimate Shear Connector Strength given Number of Connectors in Bridges evaluator uses Ultimate Shear Connector Stress = Slab Force/(No of Connector in Bridge*Reduction Factor) to evaluate the Ultimate Shear Connector Stress, The Ultimate Shear Connector Strength given Number of Connectors in Bridges formula is defined as the maximum design shear strength of the member after which it yields. Ultimate Shear Connector Stress is denoted by Sultimate symbol.

How to evaluate Ultimate Shear Connector Strength given Number of Connectors in Bridges using this online evaluator? To use this online evaluator for Ultimate Shear Connector Strength given Number of Connectors in Bridges, enter Slab Force (Pon slab), No of Connector in Bridge (N) & Reduction Factor (Φ) and hit the calculate button.

FAQs on Ultimate Shear Connector Strength given Number of Connectors in Bridges

What is the formula to find Ultimate Shear Connector Strength given Number of Connectors in Bridges?
The formula of Ultimate Shear Connector Strength given Number of Connectors in Bridges is expressed as Ultimate Shear Connector Stress = Slab Force/(No of Connector in Bridge*Reduction Factor). Here is an example- 0.019216 = 245000/(15*0.85).
How to calculate Ultimate Shear Connector Strength given Number of Connectors in Bridges?
With Slab Force (Pon slab), No of Connector in Bridge (N) & Reduction Factor (Φ) we can find Ultimate Shear Connector Strength given Number of Connectors in Bridges using the formula - Ultimate Shear Connector Stress = Slab Force/(No of Connector in Bridge*Reduction Factor).
What are the other ways to Calculate Ultimate Shear Connector Stress?
Here are the different ways to Calculate Ultimate Shear Connector Stress-
  • Ultimate Shear Connector Stress=(Slab Force+Force in Slab at Negative Moment Point)/(Reduction Factor*No of Connector in Bridge)OpenImg
Can the Ultimate Shear Connector Strength given Number of Connectors in Bridges be negative?
Yes, the Ultimate Shear Connector Strength given Number of Connectors in Bridges, measured in Force can be negative.
Which unit is used to measure Ultimate Shear Connector Strength given Number of Connectors in Bridges?
Ultimate Shear Connector Strength given Number of Connectors in Bridges is usually measured using the Kilonewton[kN] for Force. Newton[kN], Exanewton[kN], Meganewton[kN] are the few other units in which Ultimate Shear Connector Strength given Number of Connectors in Bridges can be measured.
Copied!