Ultimate Load per Area for Cast Iron Columns Formula

Fx Copy
LaTeX Copy
The Ultimate Load is a statistical figure used in calculations and should (hopefully) never actually occur. Strength requirements are specified in terms of limit loads and ultimate loads. Check FAQs
P=(34000-88(λ))A
P - Ultimate Load?λ - Slenderness Ratio?A - Section Area of Column?

Ultimate Load per Area for Cast Iron Columns Example

With values
With units
Only example

Here is how the Ultimate Load per Area for Cast Iron Columns equation looks like with Values.

Here is how the Ultimate Load per Area for Cast Iron Columns equation looks like with Units.

Here is how the Ultimate Load per Area for Cast Iron Columns equation looks like.

1796.2724Edit=(34000-88(0.5Edit))52900Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Columns » fx Ultimate Load per Area for Cast Iron Columns

Ultimate Load per Area for Cast Iron Columns Solution

Follow our step by step solution on how to calculate Ultimate Load per Area for Cast Iron Columns?

FIRST Step Consider the formula
P=(34000-88(λ))A
Next Step Substitute values of Variables
P=(34000-88(0.5))52900mm²
Next Step Convert Units
P=(34000-88(0.5))0.0529
Next Step Prepare to Evaluate
P=(34000-88(0.5))0.0529
LAST Step Evaluate
P=1796.2724N

Ultimate Load per Area for Cast Iron Columns Formula Elements

Variables
Ultimate Load
The Ultimate Load is a statistical figure used in calculations and should (hopefully) never actually occur. Strength requirements are specified in terms of limit loads and ultimate loads.
Symbol: P
Measurement: ForceUnit: N
Note: Value should be greater than 0.
Slenderness Ratio
Slenderness Ratio is the ratio of the length of a column and the least radius of gyration of its cross section.
Symbol: λ
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Section Area of Column
The Section Area of Column is the area of a two-dimensional shape that is obtained when a three-dimensional shape is sliced perpendicular to some specified axis at a point.
Symbol: A
Measurement: AreaUnit: mm²
Note: Value should be greater than 0.

Other formulas in Cast Iron Columns Design category

​Go Critical Slenderness Ratio for Cast Iron Columns
λ=12000-(QA)60
​Go Allowable Load per Area for Cast Iron Columns
Q=(12000-(60λ))A

How to Evaluate Ultimate Load per Area for Cast Iron Columns?

Ultimate Load per Area for Cast Iron Columns evaluator uses Ultimate Load = (34000-88*(Slenderness Ratio))*Section Area of Column to evaluate the Ultimate Load, The Ultimate Load per Area for Cast Iron Columns formula is defined as the Limit Load multiplied by a prescribed Safety Factor per unit cross sectional area for Cast Iron Columns. Ultimate Load is denoted by P symbol.

How to evaluate Ultimate Load per Area for Cast Iron Columns using this online evaluator? To use this online evaluator for Ultimate Load per Area for Cast Iron Columns, enter Slenderness Ratio (λ) & Section Area of Column (A) and hit the calculate button.

FAQs on Ultimate Load per Area for Cast Iron Columns

What is the formula to find Ultimate Load per Area for Cast Iron Columns?
The formula of Ultimate Load per Area for Cast Iron Columns is expressed as Ultimate Load = (34000-88*(Slenderness Ratio))*Section Area of Column. Here is an example- 1796.272 = (34000-88*(0.5))*0.0529.
How to calculate Ultimate Load per Area for Cast Iron Columns?
With Slenderness Ratio (λ) & Section Area of Column (A) we can find Ultimate Load per Area for Cast Iron Columns using the formula - Ultimate Load = (34000-88*(Slenderness Ratio))*Section Area of Column.
Can the Ultimate Load per Area for Cast Iron Columns be negative?
No, the Ultimate Load per Area for Cast Iron Columns, measured in Force cannot be negative.
Which unit is used to measure Ultimate Load per Area for Cast Iron Columns?
Ultimate Load per Area for Cast Iron Columns is usually measured using the Newton[N] for Force. Exanewton[N], Meganewton[N], Kilonewton[N] are the few other units in which Ultimate Load per Area for Cast Iron Columns can be measured.
Copied!