Fx Copy
LaTeX Copy
Ultimate Bearing Capacity is defined as the minimum gross pressure intensity at the base of the foundation at which the soil fails in shear. Check FAQs
qf=qnet'+(γDfooting)
qf - Ultimate Bearing Capacity?qnet' - Net Ultimate Bearing Capacity?γ - Unit Weight of Soil?Dfooting - Depth of Footing in Soil?

Ultimate Bearing Capacity given Depth of Footing Example

With values
With units
Only example

Here is how the Ultimate Bearing Capacity given Depth of Footing equation looks like with Values.

Here is how the Ultimate Bearing Capacity given Depth of Footing equation looks like with Units.

Here is how the Ultimate Bearing Capacity given Depth of Footing equation looks like.

51.02Edit=5.3Edit+(18Edit2.54Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Geotechnical Engineering » fx Ultimate Bearing Capacity given Depth of Footing

Ultimate Bearing Capacity given Depth of Footing Solution

Follow our step by step solution on how to calculate Ultimate Bearing Capacity given Depth of Footing?

FIRST Step Consider the formula
qf=qnet'+(γDfooting)
Next Step Substitute values of Variables
qf=5.3kN/m²+(18kN/m³2.54m)
Next Step Convert Units
qf=5300Pa+(18000N/m³2.54m)
Next Step Prepare to Evaluate
qf=5300+(180002.54)
Next Step Evaluate
qf=51020Pa
LAST Step Convert to Output's Unit
qf=51.02kPa

Ultimate Bearing Capacity given Depth of Footing Formula Elements

Variables
Ultimate Bearing Capacity
Ultimate Bearing Capacity is defined as the minimum gross pressure intensity at the base of the foundation at which the soil fails in shear.
Symbol: qf
Measurement: PressureUnit: kPa
Note: Value should be greater than 0.
Net Ultimate Bearing Capacity
Net Ultimate Bearing Capacity is the maximum load per unit area that a soil can withstand without failure under the conditions imposed by the presence of groundwater.
Symbol: qnet'
Measurement: PressureUnit: kN/m²
Note: Value should be greater than 0.
Unit Weight of Soil
Unit Weight of Soil mass is the ratio of the total weight of soil to the total volume of soil.
Symbol: γ
Measurement: Specific WeightUnit: kN/m³
Note: Value should be greater than 0.
Depth of Footing in Soil
Depth of Footing in Soil is the depth at which the foundation of a structure is placed below the ground surface. This is crucial for ensuring the stability of the structure.
Symbol: Dfooting
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other Formulas to find Ultimate Bearing Capacity

​Go Ultimate Bearing Capacity of Soil under Long Footing at Surface of Soil
qf=((Ctan(Φi))+(0.5γdBKP)(KPexp(πtan(Φi))-1))
​Go Ultimate Bearing Capacity
qf=qnet+σs

Other formulas in Bearing Capacity of Soils category

​Go Effective Surcharge given Depth of Footing
σs=γD
​Go Net Ultimate Bearing Capacity given Ultimate Bearing Capacity
qnet=qf-σs
​Go Net Safe Bearing Capacity
qnsa=qnet'FOS
​Go Net Ultimate Bearing Capacity given Net Safe Bearing Capacity
qnet'=qnsaFOS

How to Evaluate Ultimate Bearing Capacity given Depth of Footing?

Ultimate Bearing Capacity given Depth of Footing evaluator uses Ultimate Bearing Capacity = Net Ultimate Bearing Capacity+(Unit Weight of Soil*Depth of Footing in Soil) to evaluate the Ultimate Bearing Capacity, The Ultimate Bearing Capacity given Depth of Footing formula is defined as the maximum load per unit area that a foundation soil can support without causing shear failure. This parameter is crucial in determining the safe design of foundations for structures like buildings, bridges, or other heavy infrastructure. Ultimate Bearing Capacity is denoted by qf symbol.

How to evaluate Ultimate Bearing Capacity given Depth of Footing using this online evaluator? To use this online evaluator for Ultimate Bearing Capacity given Depth of Footing, enter Net Ultimate Bearing Capacity (qnet'), Unit Weight of Soil (γ) & Depth of Footing in Soil (Dfooting) and hit the calculate button.

FAQs on Ultimate Bearing Capacity given Depth of Footing

What is the formula to find Ultimate Bearing Capacity given Depth of Footing?
The formula of Ultimate Bearing Capacity given Depth of Footing is expressed as Ultimate Bearing Capacity = Net Ultimate Bearing Capacity+(Unit Weight of Soil*Depth of Footing in Soil). Here is an example- 0.05102 = 5300+(18000*2.54).
How to calculate Ultimate Bearing Capacity given Depth of Footing?
With Net Ultimate Bearing Capacity (qnet'), Unit Weight of Soil (γ) & Depth of Footing in Soil (Dfooting) we can find Ultimate Bearing Capacity given Depth of Footing using the formula - Ultimate Bearing Capacity = Net Ultimate Bearing Capacity+(Unit Weight of Soil*Depth of Footing in Soil).
What are the other ways to Calculate Ultimate Bearing Capacity?
Here are the different ways to Calculate Ultimate Bearing Capacity-
  • Ultimate Bearing Capacity=((Prandtls Cohesion/tan(Angle of Internal Friction of Soil))+(0.5*Dry Unit Weight of Soil*Width of Footing*sqrt(Coefficient of Passive Pressure))*(Coefficient of Passive Pressure*exp(pi*tan(Angle of Internal Friction of Soil))-1))OpenImg
  • Ultimate Bearing Capacity=Net Ultimate Bearing Capacity of Soil+Effective Surcharge in Kilo PascalOpenImg
Can the Ultimate Bearing Capacity given Depth of Footing be negative?
No, the Ultimate Bearing Capacity given Depth of Footing, measured in Pressure cannot be negative.
Which unit is used to measure Ultimate Bearing Capacity given Depth of Footing?
Ultimate Bearing Capacity given Depth of Footing is usually measured using the Kilopascal[kPa] for Pressure. Pascal[kPa], Bar[kPa], Pound Per Square Inch[kPa] are the few other units in which Ultimate Bearing Capacity given Depth of Footing can be measured.
Copied!