Tube inside area required for heat exchange Formula

Fx Copy
LaTeX Copy
The area is the amount of two-dimensional space taken up by an object. Check FAQs
A=QUoverallΔTm
A - Area?Q - Heat Flow Rate?Uoverall - Overall Heat Transfer Coefficient?ΔTm - Logarithmic Mean Temperature Difference?

Tube inside area required for heat exchange Example

With values
With units
Only example

Here is how the Tube inside area required for heat exchange equation looks like with Values.

Here is how the Tube inside area required for heat exchange equation looks like with Units.

Here is how the Tube inside area required for heat exchange equation looks like.

16.6667Edit=125Edit0.25Edit30Edit
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Heat and Mass Transfer » fx Tube inside area required for heat exchange

Tube inside area required for heat exchange Solution

Follow our step by step solution on how to calculate Tube inside area required for heat exchange?

FIRST Step Consider the formula
A=QUoverallΔTm
Next Step Substitute values of Variables
A=125W0.25W/m²*K30
Next Step Prepare to Evaluate
A=1250.2530
Next Step Evaluate
A=16.6666666666667
LAST Step Rounding Answer
A=16.6667

Tube inside area required for heat exchange Formula Elements

Variables
Area
The area is the amount of two-dimensional space taken up by an object.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Heat Flow Rate
Heat Flow Rate is the amount of heat that is transferred per unit of time in some material, usually measured in watt. Heat is the flow of thermal energy driven by thermal non-equilibrium.
Symbol: Q
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Overall Heat Transfer Coefficient
Overall heat transfer coefficient is the overall convective heat transfer between a fluid medium (a fluid) and the surface (wall) flowed over by the fluid.
Symbol: Uoverall
Measurement: Heat Transfer CoefficientUnit: W/m²*K
Note: Value should be greater than 0.
Logarithmic Mean Temperature Difference
Logarithmic Mean Temperature Difference is the log of the mean of the temperature values.
Symbol: ΔTm
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other formulas in Fin Parameters category

​Go Equivalent diameter of tube for transverse fin heat exchanger
De=ReμΔm
​Go Number of tubes in transverse fin heat exchanger
N=mGTPhc
​Go Distance between two consequent tubes in transverse fin heat exchanger
TP=mGNL
​Go Length of tube bank
L=mGNTP

How to Evaluate Tube inside area required for heat exchange?

Tube inside area required for heat exchange evaluator uses Area = Heat Flow Rate/(Overall Heat Transfer Coefficient*Logarithmic Mean Temperature Difference) to evaluate the Area, The Tube inside area required for heat exchange formula is defined as the area required inside the tube for effective heat exchange between the flowing fluid and the inside surface. Area is denoted by A symbol.

How to evaluate Tube inside area required for heat exchange using this online evaluator? To use this online evaluator for Tube inside area required for heat exchange, enter Heat Flow Rate (Q), Overall Heat Transfer Coefficient (Uoverall) & Logarithmic Mean Temperature Difference (ΔTm) and hit the calculate button.

FAQs on Tube inside area required for heat exchange

What is the formula to find Tube inside area required for heat exchange?
The formula of Tube inside area required for heat exchange is expressed as Area = Heat Flow Rate/(Overall Heat Transfer Coefficient*Logarithmic Mean Temperature Difference). Here is an example- 16.66667 = 125/(0.25*30).
How to calculate Tube inside area required for heat exchange?
With Heat Flow Rate (Q), Overall Heat Transfer Coefficient (Uoverall) & Logarithmic Mean Temperature Difference (ΔTm) we can find Tube inside area required for heat exchange using the formula - Area = Heat Flow Rate/(Overall Heat Transfer Coefficient*Logarithmic Mean Temperature Difference).
Can the Tube inside area required for heat exchange be negative?
No, the Tube inside area required for heat exchange, measured in Area cannot be negative.
Which unit is used to measure Tube inside area required for heat exchange?
Tube inside area required for heat exchange is usually measured using the Square Meter[m²] for Area. Square Kilometer[m²], Square Centimeter[m²], Square Millimeter[m²] are the few other units in which Tube inside area required for heat exchange can be measured.
Copied!