True Value of Quality factor Formula

Fx Copy
LaTeX Copy
Quality Factor True Value is the actual, precise measurement of the quality factor, representing the ratio of energy stored to energy dissipated per cycle in a resonant circuit. Check FAQs
Qtrue=ωLTRT
Qtrue - Quality Factor True Value?ω - Angular Frequency?LT - Total Inductance?RT - Total Resistance?

True Value of Quality factor Example

With values
With units
Only example

Here is how the True Value of Quality factor equation looks like with Values.

Here is how the True Value of Quality factor equation looks like with Units.

Here is how the True Value of Quality factor equation looks like.

7.75Edit=31Edit1.5Edit6Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics and Instrumentation » Category Measuring Instrument Circuits » fx True Value of Quality factor

True Value of Quality factor Solution

Follow our step by step solution on how to calculate True Value of Quality factor?

FIRST Step Consider the formula
Qtrue=ωLTRT
Next Step Substitute values of Variables
Qtrue=31rad/s1.5H6Ω
Next Step Prepare to Evaluate
Qtrue=311.56
LAST Step Evaluate
Qtrue=7.75

True Value of Quality factor Formula Elements

Variables
Quality Factor True Value
Quality Factor True Value is the actual, precise measurement of the quality factor, representing the ratio of energy stored to energy dissipated per cycle in a resonant circuit.
Symbol: Qtrue
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Angular Frequency
Angular Frequency refers to the rate of change of angular displacement of an alternating current or voltage with respect to time.
Symbol: ω
Measurement: Angular FrequencyUnit: rad/s
Note: Value should be greater than 0.
Total Inductance
Total Inductance refers to the combined inductance of all inductors in a circuit, calculated either in series or in parallel, influencing the overall inductive reactance observed across the circuit.
Symbol: LT
Measurement: InductanceUnit: H
Note: Value should be greater than 0.
Total Resistance
Total Resistance refers to the combined resistance of all resistors in a circuit, calculated either in series or in parallel, influencing the overall resistance observed across the circuit.
Symbol: RT
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.

Other formulas in Q Meter category

​Go Measured Value of Quality Factor
Qm=ωLTRT+Rsh
​Go Value of Inductance
LT=14π2fo2CT
​Go Value of Resistance
RT=ωLTQm
​Go Value of distributed capacitor
Cd=C1-4C23

How to Evaluate True Value of Quality factor?

True Value of Quality factor evaluator uses Quality Factor True Value = (Angular Frequency*Total Inductance)/Total Resistance to evaluate the Quality Factor True Value, The True Value of Quality factor formula is defined as the actual, precise measurement of the quality factor, representing the ratio of energy stored to energy dissipated per cycle in a resonant circuit. Quality Factor True Value is denoted by Qtrue symbol.

How to evaluate True Value of Quality factor using this online evaluator? To use this online evaluator for True Value of Quality factor, enter Angular Frequency (ω), Total Inductance (LT) & Total Resistance (RT) and hit the calculate button.

FAQs on True Value of Quality factor

What is the formula to find True Value of Quality factor?
The formula of True Value of Quality factor is expressed as Quality Factor True Value = (Angular Frequency*Total Inductance)/Total Resistance. Here is an example- 18.6 = (31*1.5)/6.
How to calculate True Value of Quality factor?
With Angular Frequency (ω), Total Inductance (LT) & Total Resistance (RT) we can find True Value of Quality factor using the formula - Quality Factor True Value = (Angular Frequency*Total Inductance)/Total Resistance.
Copied!